T.I.P. EJ 5 Plus Operating Instructions Manual Download Page 10

 

 

 

Dear customer, 

Congratulation for buying your new device from T.I.P.! 

Like all our products, this one, too, was developed using the latest technological knowledge. The device was 

manufactured and assembled on the basis of state-of-the-art pump technology using most reliable electrical or 

electronic components which ensure a high level of quality and a long life of your new product. 

Please read through these operating instructions carefully to make sure that you can fully benefit from all features. 

Some explanatory illustrations can be found at the end of these operating instructions. 

 

We hope you will enjoy your new device! 

 

Table of contents 

 

1.

 

General safety information ............................................................................................................................. 1

 

2.

 

Range of use .................................................................................................................................................. 2

 

3.

 

Technical Data ............................................................................................................................................... 2

 

4.

 

Scope of delivery ........................................................................................................................................... 2

 

5.

 

Installation ...................................................................................................................................................... 3

 

6.

 

Electrical connection ...................................................................................................................................... 4

 

7.

 

Putting into operation ..................................................................................................................................... 4

 

8.

 

Automation with special accessories ............................................................................................................. 5

 

9.

 

Maintenance and troubleshooting .................................................................................................................. 5

 

10.

 

Warranty ........................................................................................................................................................ 6

 

11.

 

How to order spare parts ................................................................................................................................ 7

 

12.

 

Service ........................................................................................................................................................... 7

 

         Annex: Illustrations 

 

 

1.  General safety information 

 

Please read through these operating instructions carefully and make yourself conversant with the control 

elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of 

the non-observance of instructions and provisions of the present operating instructions. Any damage caused as a 

result of the non-observance of the instructions and regulations contained in the present operating instructions 

shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand 

them on together with the device should you ever dispose of it. 

 

Persons not conversant with the contents of these operating instructions must not 

use this device. 

 

The pump must not be used by children. 

The pump may be used by persons with reduced physical, sensory or mental 

capabilities or lack of experience and / or knowledge if they have been supervised or 

instructed in the safe use of the equipment and have understood the resulting 

hazards. Children are not allowed to play with the device. Keep the appliance and its 

cord out of reach of children. 

 

The pump must not be used when people are in the water. 

 

The pump must be supplied through a residual current device (RCD) having a rated 

residual operating current not exceeding 30mA. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified persons in order to avoid a hazard. 

 

Notes and instructions with the following symbols require particular attention: 

 

 

 

Any non-observance of these instructions involves the danger of bodily harm to people and/or 

damage to property. 

 

8

Summary of Contents for EJ 5 Plus

Page 1: ...6 Plus Gebrauchsanweisung Zisternenpumpe 01 Operating Instructions deep well pump 08 Mode d emploi Pompe pour citernes 15 Istruzioni per l uso Pompa per cisterna 22 Instrucciones para el manejo Bomba...

Page 2: ...CE La ditta T I P GmbH Technische Industrie Produkte sita in Siemensstr 17 D 74915 a Waibstadt dichiara sotto la propria responsabilit che i prodotti sotto indicati sono costruiti in conformit con le...

Page 3: ...iner Missach tung von Anweisungen und Vorschriften dieser Gebrauchsanweisung verursacht werden Sch den in Folge einer Missachtung von Anweisungen und Vorschriften dieser Gebrauchsanweisung fallen nich...

Page 4: ...ereich und nicht f r gewerbliche bzw industrielle Zwe cke oder zum Dauerumw lzbetrieb bestimmt Die Pumpe eignet sich nicht zur F rderung von Salzwasser F kalien entflammbaren tzen den explosiven oder...

Page 5: ...Drucks nach dem Abschalten der Pumpe verhindert Die serienm ige Ausstattung der Modelle Art Nr 30156 30164 und 30196 umfasst eine hochwertige Ansaug garnitur Sie besteht aus einem speziell gefertigte...

Page 6: ...da sie nur in vertikaler Position betrieben werden darf Achten Sie darauf dass das Ger t nicht gegen den Rand der Vertiefung schl gt oder an diesem reibt Die Pumpe muss vollst ndig in die Fl ssigkeit...

Page 7: ...lektronisches oder mechanisches Steuerungssystem bei Art Nr 30164 und 30196 im Lieferumfang enthalten welches sich sehr einfach und mit wenigen Handgriffen installieren l sst Einige Steuerungssysteme...

Page 8: ...3 3 3 Siehe Punkt 3 4 4 Netzspannung au erhalb der Toleranz 5 Motor defekt 1 Siehe Punkte 2 1 bis 2 5 2 Siehe Punkt 3 3 3 Siehe Punkt 3 4 4 Daf r sorgen dass die Netzspannung den Angaben auf dem Typen...

Page 9: ...4 Das beim Garantiegeber T I P einzusendende Paket ist durch den Kunden ordnungsgem zu frankieren Die Einsendung des Ger ts zur Reparatur und die Geltendmachung der Rechte aus dieser Garantie erfolge...

Page 10: ...he non observance of instructions and provisions of the present operating instructions Any damage caused as a result of the non observance of the instructions and regulations contained in the present...

Page 11: ...for continuous circulating The pump is not suited to discharge saltwater faeces inflammable etching explosive or other hazardous liquids Please observe the max Temperature of the liquids to be discha...

Page 12: ...t check valve with an intake filter 4 plus a highly efficient float 5 The suction hose usually comes with the check valve plus intake filter and the connection piece 6 for the suction port of the pump...

Page 13: ...shaft etc during operation Therefore it is recommended to apply a suitable device at the opening of the well shaft where the lowering rope can be fastened after the proper positioning of the pump When...

Page 14: ...lack of water Our range of accessories contains some particularly reliable and proven control systems For detailed information please refer to www tip pumpen de or to your specialised dealer 9 Mainte...

Page 15: ...Refer to section 3 4 4 Mains voltage out of tolerance 5 Motor is defective 1 Please refer to items 2 1 to 2 5 2 Refer to section 3 3 3 Refer to section 3 4 4 Make sure that mains voltage matches that...

Page 16: ...net On our www tip pumpen de website you will find a convenient spare part shop where you can order spare parts with just a couple of clicks In addition this is also the place where we publish compreh...

Page 17: ...nes Les d g ts caus s suite du non respect des instructions et consignes ne sont pas couverts par la garantie Gardez ce mode d emploi il doit tre transmis tout usager qui on aurait c d la pompe Les pe...

Page 18: ...u industrielles ou pour le pompage turbinage permanent Ne v hiculer ni eau sal e ni mati res f cales ni produits inflammables corrosifs explosifs ou d autre liquides dangereuses Le d bit ne doit surpa...

Page 19: ...itif d aspiration haut de gamme Il se compose d un flexible d aspiration 3 con u sp cifiquement en tant que conduite d aspiration d un clapet anti retour performant avec filtre d aspiration 4 ainsi qu...

Page 20: ...t e L entr e de la conduite d aspiration doit se trouver au moins 0 5 m au dessous de la surface de l eau Cela vite d aspirer de l air L entr e de la conduite d aspiration doit se trouver au moins 0 5...

Page 21: ...ant d une conduite d eau en ouvrant ou fermant des robinets ou d autres consommateurs Pour l automatisation vous avez besoin d un syst me de commande lectronique ou m canique qui est facile installer...

Page 22: ...la marche sec 4 La pompe se met en marche et s arr te trop fr quemment 1 Cf les points 2 1 2 5 2 Voir point 3 3 3 Voir point 3 4 4 La tension du r seau est hors tol rance 5 Moteur d fectueux 1 Cf les...

Page 23: ...ces de rechange est par internet Notre site www tip pumpen de a un magasin confortable ce qui vous permet de faire une commande de pi ces de rechange simplement en cliquant En plus nous y publions de...

Page 24: ...avvertenze e disposizioni contenute in tali istruzioni non sono coperti da garanzia Conservare con cura queste istruzioni e consegnarle insieme al macchinario ad un eventuale possessore successivo Il...

Page 25: ...o a circolazione continua La pompa non adatta al pompaggio di acqua salata feci liquidi infiammabili corrosivi esplosivi e comunque pericolosi Il liquido pompato non pu superare la temperatura massima...

Page 26: ...nda inoltre vivamente l installazione di una valvola antiritorno all ingresso della linea di aspirazione che impedisce uno sfiato della pressione dopo lo spegnimento della pompa La dotazione di serie...

Page 27: ...nastro adesivo o fascette stringicavo per evitare che questi si aggroviglino durante il sollevamento o l immersione della pompa Immergere con cautela la pompa calandola in posizione verticale e facend...

Page 28: ...ispositivo di sicurezza molto efficiente contro danni provocati dal funzionamento a secco che blocca la pompa in caso di scarsit d acqua Noi offriamo sistemi di comando accessori particolarmente affid...

Page 29: ...al 2 5 2 Vedi punto 3 3 3 Vedi punto 3 4 4 Tensione di corrente non compatibile 5 Motore difettoso 1 Vedi dal punto 2 1 al 2 5 2 Vedi punto 3 3 3 Vedi punto 3 4 4 Assicurarsi che la tensione di corre...

Page 30: ...ro sito www tip pumpen de dispone di un comodo shop per i pezzi i ricambio che rende possibile l ordine solo con poche cliccate Vi vengono inoltre pubblicate vaste informazioni e consigli preziosi rig...

Page 31: ...y los requisitos de este manual de instrucciones no est n cubiertos por la garant a Guarde este manual de instrucciones y adj ntelas en caso de transmisi n del dispositivo No se autoriza el uso de est...

Page 32: ...iamente inofensivos 3 Datos t cnicos Modelo EJ 5 Plus EJ 6 Plus Tensi n Frecuencia 230 V 50 Hz 230 V 50 Hz Potencia nominal 1 000 Watt 1 250 Watt Tipo de protecci n IP68 IP68 Conexi n de la aspiraci n...

Page 33: ...i no fuera el caso el montaje se realiza en pocas maniobras Introduzca primero la v lvula de retenci n con el filtro de aspiraci n en un extremo final de la manguera de aspiraci n Para la sujeci n uti...

Page 34: ...os acoplamientos tienen que estar protegidos contra salpicaduras de agua 7 Puesta en marcha Durante el funcionamiento de la bomba no se debe encontrar ninguna persona en el agua La bomba solo puede se...

Page 35: ...liminaci n Todas las medidas mencionadas deber n ser realizadas cuando la bomba haya sido desconectada de la red Si usted no puede eliminar la aver a consulte a su electricista Reparaciones m s extens...

Page 36: ...os a indemnizaci n por da os y perjuicios est n excluidos a menos que estos sean producidos por falta deliberada o grave negligencia del fabricante En la garant a no se incluyen otros derechos que los...

Page 37: ...Anhang Abbildungen Annex Illustrations Annexe Illustrations Appendice Illustrazioni Ap ndice Imagenes EJ 5 Plus EJ 6 Plus...

Page 38: ...14 Brio 2000 M...

Page 39: ...etenue avec filtre d aspiration 1 9 Raccord de refoulement 14 BRIO 2000 M 2 5 Flotteur 1 10 Corde 1 Les pi ces 2 8 ne sont pas fournies avec le mod le r f 30170 30195 2 Les pi ce 14 ne sont pas fourni...

Page 40: ...10 2018 T I P Technische Industrie Produkte GmbH Siemensstra e 17 D 74915 Waibstadt Germany service tip pumpen de www tip pumpen de...