background image

 

 

 

 

5.2. 

Installation of the pressure line 

 

This pump is equipped with a garden hose adapter as standard.

 

Connect the garden hose to the pump's adapter with a quick 
coupling (Fig. 1) to drain the waste water from the pool. This 
allows the pump to be mounted and disassembled quickly and 
easily.  

 
 
 
 

 

 

 

 

 

 

 

 

 

Fig. 1 

 

To avoid flow losses, it is advisable to use a pressure line with a diameter equal to that of the pump pressure 
connection as a minimum.  
Use a flexible hose suitable for this purpose, e.g. a commercially available garden hose or similar, as a pressure 
line. 
 

 

5.3. 

StatiPositioning the pump 

 

 

Place the pump in the deepest part of the water on your pool cover. The pump must be installed in a horizontal 
position. Point the open end of the pool's garden hose away from the pool. Connect the pump to the electrical 
circuit (Fig.2). 
In addition, when positioning the pump, make sure that the maximum immersion depth specified in the technical 
data is not exceeded. During subsequent operation, the water level will then be reduced to the minimum suction 
level (Fig. 3). 

 

 

 

Fig. 2 

 

 

 

 

 

 

Fig. 3 

 
 
 

6.  Electrical connection 

 

The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to 
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to 
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp 
edges. 

 

 

The values stated in the technical details have to correspond to the mains voltage. The person 
responsible for the installation has to make sure that the electrical connection is earthed in 
compliance with the applicable standards. 

 

 

The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739). 

 

 

If extension cables are used, their cross-section must not be smaller than that of rubber-
sheathed cables of the H05RN-F (3 x 0.75 mm²) short code. The mains socket and the plug-
and-socket elements have to be in splash water-proof design. 

 

7.  Putting into operation 

 

 

Please make sure that the electrical plug connections are in the flood-proof area. 

 

 

As long as the device is connected to the electrical mains, one must never re

ach with one’s 

hands into the opening of the pump. 

 

9

Summary of Contents for CoverOne 1500 AUT

Page 1: ...operating instructions Pool cover pump Az eredeti haszn lati tmutat ford t sa Medenceburkolat szivatty Traduction du mode d emploi d origine Pompe pour protection de piscine T umaczenie oryginalnej i...

Page 2: ...GmbH Technische Industrie Produkte sita in Siemensstr 17 D 74915 a Waibstadt dichiara sotto la propria responsabilit che i prodotti sotto indicati sono costruiti in con formit con le direttive EU in v...

Page 3: ...Pumpe darf nicht von Kindern benutzt werden Die Pumpe kann von Personen mit reduzierten physischen sensorischen oder men talen F higkeiten oder Mangel an Erfahrung und oder Wissen benutzt werden wenn...

Page 4: ...schluss AG 26 44 mm Max F rdermenge Qmax 1 1 300 l h Max Druck 0 16 bar Max F rderh he Hmax 1 1 6 m Max Eintauchtiefe 1 m Max Gr e der gepumpten Festk rper 2 mm Max Temperatur der gepumpten Fl ssigkei...

Page 5: ...en tiefsten Bereich des Wassers auf Ihrer Poolabdeckung Die Pumpe muss in horizon taler Position installiert werden Richten Sie das offene Ende des Gartenschlauchs des Pools weg Schlie en Sie die Pump...

Page 6: ...die Gefahr m glicher Betriebsst rungen und tr gt dazu bei die Lebensdauer Ihres Ger tes zu verl ngern Schmirgelnde Stoffe in der F rderfl ssigkeit wie beispielsweise Sand beschleunigen den Verschlei...

Page 7: ...e gesetzlichen M ngelrechte durch die Garantie nicht ein geschr nkt Die Garantiezeit beginnt mit dem Tag des Kaufs des Ger tes durch den Kunden zu nachfolgenden Bedingungen I Innerhalb der Garantiezei...

Page 8: ...rliegenden Gebrauchsanweisung 10 Bestellung von Ersatzteilen Die schnellste einfachste und preiswerteste M glichkeit Ersatzteile zu bestellen erfolgt ber das Internet Unse re Webseite www tip pumpen d...

Page 9: ...ersons with reduced physical sensory or mental capabilities or lack of experience and or knowledge if they have been supervised or instructed in the safe use of the equipment and have understood the r...

Page 10: ...Scope of delivery The scope of the delivery of this product includes One pump with connection cable one connection port one operating manual Please verify that the scope of delivery is complete Depend...

Page 11: ...evel Fig 3 Fig 2 Fig 3 6 Electrical connection The unit is equipped with a mains connection cable and a mains plug It must only be replaced by qualified staff to avoid any danger Please do not use the...

Page 12: ...below the freezing point of the liquid Please store the pump in a dry frost protected place In the case of malfunction you should first of all check whether it was caused by an operating error or som...

Page 13: ...by the purchaser in the form of the submission of the sales receipt The present warranty commitment is valid in the country in which the device was purchased Please note 1 Should your device fail to...

Page 14: ...physiques sensorielles ou mentales r duites ou manquant d exp rience et ou de connaissances que si elles sont sous la surveillance ou ont t form es l utilisation en toute s curit de l appareil et comp...

Page 15: ...m des corps solides pomp s 2 mm Temp rature maxi du liquide pomp Tmax 35 C Nombre maximum de d marrages par heure 30 uniform ment Longueur du c ble de raccordement 10 m Type de c ble H05RN F Poids net...

Page 16: ...cine La pompe doit tre install e en position horizontale Orientez l extr mit ouverte du tuyau d arrosage de la piscine vers l ext rieur Raccordez la pompe au circuit lectrique Fig 2 En outre lors du p...

Page 17: ...l eau dans la pompe g le C est pourquoi il faut vider la pompe compl tement quand la temp rature baisse jusqu au point de cong lation Rangez la pompe dans un endroit sec l abri du gel En cas de panne...

Page 18: ...acqu reur sur pr sentation de la facture Cette promesse de garantie est valable dans les pays dans lequel vous avez achet l appareil Renseignements 1 Dans le cas o votre appareil ne fonctionne plus v...

Page 19: ...ompa pu essere utilizzata da persone con facolt fisiche psichiche e mentali ridotte o che manchino di esperienza e o conoscenze specifiche in merito al suo uso solo nel caso in cui siano sorvegliate o...

Page 20: ...numero di accensioni in un ora 30 regolarmente distribuite Lunghezza del cavo di collegamento 10 m Modello del cavo di collegamento H05RN F Peso netto 1 3 kg Livello di accensione 25 mm Livello di arr...

Page 21: ...a pompa occorre assicurarsi di non superare la profondit di immersione massima riportata nei dati tecnici Durante il funzionamento successivo ridurre poi il livello dell acqua fino al livello di aspir...

Page 22: ...evitare danni gni altro tipo di smontaggio e sostituzione di componenti puo essere eseguito solo dal produttore o dal servizio clienti autorizzato In caso di gelo la presenza di acqua nella pompa puo...

Page 23: ...arcimento di danni sono esclusi finche questi non sono da attribuire ad intenzioni o evidente negligenza del produttore Ulteriori ricorsi di garanzia non vengono contemplati Il diritto di garanzia da...

Page 24: ...cciones de uso Se proh be a los ni os el empleo de la bomba La bomba puede ser utilizada por personas con capacidades f sicas mentales o sensoriales disminuidas o con falta de experiencia y o conocimi...

Page 25: ...Longitud del cable de conexi n 10 m Modelo del cable H05RN F Peso neto 1 3 kg Nivel de inicio 25 mm Nivel de desconexi n 20 mm Dimensiones L x P x A 17 x 11 x 11 cm N mero de art culo 30441 1 Los ren...

Page 26: ...able para la conexi n de la red con enchufe Cable y enchufe sole pueden ser cambiados por personal adecuado para evitar peligros No carge la bomba por el cable y no lo utilice para sacar el enchufe de...

Page 27: ...irar completamente el l quido bombeado de la bomba Almacene la bomba en un lugar seco y seguro de heladas En caso de aver as controle si hay un error de manejo u otra raz n que no est n causados por u...

Page 28: ...o por el cliente mediante el comprobante de pago El derecho de garant a es v lida en el pa s en el cual ha sido adquirido el dispositivo Indicaciones especiales 1 En caso de que su dispositivo no func...

Page 29: ...haszn lhatj k a szivatty t A szivatty t korl tozott fizikai rz kel si vagy szellemi tulajdons gokkal rendelkez szem lyek illetve csek ly tapasztalattal s vagy tud ssal rendelkez szem lyek is haszn lh...

Page 30: ...10 m Csatlakoz k bel t pusa H05RN F S ly nett 1 3 kg Ind t si szint 25 mm Kikapcsol si szint 20 mm M retei hossz x m lys g x magass g 17 x 11 x 11 cm Cikksz m 30441 1 Az rt keket sz k t s n lk li aka...

Page 31: ...x bemer t si m lys get nem szabad t ll pni A m k d s sor n a v zszint a min elsz v si szintig cs kken 3 bra 2 bra 3 bra 6 Villamos csatlakoz s A k sz l k h l zati csatlakoz k bellel s h l zati dugassz...

Page 32: ...eztet s elker lhet legyen Fagy eset n a szivatty ban tal lhat v z megfagyva komoly k rosod sokat okozhat Ez rt fagy k zeli h m rs kletekn l a szivatty t ki kell venni a sz ll tand folyad kb l s teljes...

Page 33: ...az orsz gban lehet rv nyes teni ahol a berendez st megv s rolt k K l nleges tmutat sok 1 Ha az n berendez se m r nem m k dik j l el sz r azt vizsg lja meg hogy kezel si hiba t rt nt e vagy olyan ok ll...

Page 34: ...e by u ywana przez dzieci Pompa mo e by obs ugiwana przez osoby o ograniczonej sprawno ci fizycznej sensorycznej i umys owej oraz osoby nieposiadaj ce dostatecznego do wiadczenia i lub wiedzy tylko po...

Page 35: ...pompowanych substancji sta ych 2 mm Maksymalna temperatura pompowanej cieczy Tmax 35 C Maksymalna cz sto rozruch w w ci gu godziny 30 roz o ona r wnomiernie D ugo kabla przy czeniowego 10 m Wersja ka...

Page 36: ...ej eksploatacji poziom wody jest nast pnie redukowany do minimalnego poziomu zasysania Rys 3 Rys 2 Rys 3 6 Pod czenie pompy do sieci elektrycznej Urz dzenie posiada kabel przy czeniowy z wtyczk siecio...

Page 37: ...erwisowym pozwoli to na wyeliminowanie zwi zanych z tym potencjalnych zagro e W przypadku wyst pienia mroz w zamarzaj ca woda znajduj ca si w pompie mo e spowodowa powa ne uszkodzenia dlatego w przypa...

Page 38: ...ja nie uprawnia do roszcze innego typu Podstaw uznania gwarancji stanowi przed o enie przez kupuj cego potwierdzenia zakupu Potwierdzenie gwarancji wa ne jest jedynie w kraju w kt rym dokonano zakupu...

Page 39: ...e ne smiju igrati ure ajem Ure aj i njegov priklju ni kabel valja dr ati dalje od djece Pumpa se ne smije upotrebljavati ako se u vodi zadr avaju osobe ili ivotinje Pumpa se mora napajati preko za tit...

Page 40: ...na uputa za kori tenje Provjerite jesu li sve stavke isporu ene U ovisnosti o planiranoj uporabi mo e biti potrebe i za dalje pribore vidi poglavlja Instalacija i Narud ba rezervnih dijelova Zadr ite...

Page 41: ...govarati predvi enom naponu Osoba koja je odgovorna za instaliranje se treba postarati da elektri ni priklju ci imaju propisnu uzemljenje Elektro priklju ak mora biti vezan na jako osjetljivi osigura...

Page 42: ...NJA MUGU I UZROK OTKLANJANJE 1 Pumpa ne dobavlja teku inu motor ne radi 1 Nema struje 2 Proradila termi ka za tita 3 Motor je neispravan 4 Kolo pumpe blokirano 5 Kvar plivaju eg prekida a 1 S jednim u...

Page 43: ...a popravak ili ga po aljete molimo Vas odstranite sve dodatne dijelove koji ne spadaju u originalno stanje ure aja Ukoliko to ne u inite a pri vra anju ure aja takvi dijelovi budu nedostajali ne preuz...

Page 44: ...f Dann hinterlassen Sie bitte eine ehrliche Kundenbewertung auf Amazon f r uns Weitere Kunden werden von Ihrer Erfahrung pro tieren und sich ber das Produkt freuen Sollten Sie technische Fragen oder P...

Reviews: