Tel:86-0755-26055466/26055499                            - 6 -                               web:www.comark.cn/en 

follows:  

Step 1: Examine the DIN-Rail attachment 

Step 2: Examine DIN Rail whether be firm and the position is suitability or not. 

Step 3: Insert the top of the DIN-Rail into the slot just below the stiff metal spring. 

Step 4: The DIN-Rail attachment unit will insert into place as shown below. 

 
Troubleshooting 
   

Fault Symptoms 

What to Do 

PWR off 

Check and ensure the power supply meets the requirement, and terminal 
wiring is correct or not. 

OPT off 

Check the fiber port connection, the length and type is correct or not. 

ANA on 

Received analog signal value over normal range. 

 

Package Checklist 

Please check accessories completely when open the box. 

Packing list is as follows: 

  Multi-channel fiber optic converter (with industrial terminal block for power equipment) 
 Product 

specification 

 

Product warranty card

 

Cautions

 

  The Voltage of power supply should be within 24VDC

or it may damage the product. 

  When the fiber port is not in use, please cover and protect it. 
  To avoid causing serious damage to your eyes, do not stare directly into the Laser Beam. 
  When use the relay, please conform to rating power requirement. 
  Keep low impedance with protective grounding by DIN rail or grounding cable for the product. 

 
Application 

Electric power system, transportation, energy monitor and industrial control field

 

Order Information 

 

Model 

Specifications and introduce 

Cj-KFx1 

1~4 channel unidirectional CC signal fiber optic converters, dry contact closure input SPDT Form C relay 

output, SM fiber 0 ~ 20Km,ST/SC/FC (optional). 

Cj-KFx2 

1~4 channel bidirectional CC signal fiber optic converters, dry contact closure input SPDT Form C relay 

Summary of Contents for Cj-KFx1

Page 1: ...nal Support 1 4 channel voltage current analog signal Reference accuracy 0 5 25 C Update rates 1000 2000 Hz Signal resolution 10bit Time delay 10ms Voltage signal interface parameters Voltage transmis...

Page 2: ...99 2 web www comark cn en Installation 35mmDIN Rail Wall Mounting Weight 800g Environmental Operating Temperature 40 to 7 5 Storage Temperature 40 to 8 5 Ambient Relative Humidity 90 non condensing Wa...

Page 3: ...iving indicator dry contact or TTL signal 1 Off the device has no digital signal input function 2 On the device has digital signal input function COM1 2 Serial port state indicator 1 Off no data recei...

Page 4: ...r wire input method when connecting to PLC 0 5 VDC and 0 10 VDC output Ai is the reference earth wire for each output signal while Ai is the positive signal wire for each output signal Note output cur...

Page 5: ...RX2 Dual RS485 model A2 SHIELD shield ground B2 A1 SHIELD shield ground B1 RS232 RS485model TX1 GND data ground RX1 A1 SHIELD shield ground B1 RS422 model TX SHIELD shield ground TX RX SHIELD shield...

Page 6: ...box Packing list is as follows Multi channel fiber optic converter with industrial terminal block for power equipment Product specification Product warranty card Cautions The Voltage of power supply s...

Page 7: ...0VDC SM fiber 0 20Km ST SC FC optional Cj VFx2 1 4 channel bidirectional analog signal fiber optic converters 0 10VDC SM fiber 0 20Km ST SC FC optional Cj SFx1 1 2 chs serial signal fiber optic conver...

Reviews: