![SZComark Cj-KFx1 Manual Download Page 5](http://html1.mh-extra.com/html/szcomark/cj-kfx1/cj-kfx1_manual_1423867005.webp)
Shenzhen Comark Technology Co., Ltd
More Reliable Connection, More Intellegent Life
Tel:86-0755-26055466/26055499 - 5 - web:www.comark.cn/en
Corresponding channel of the digital output interface through the optical fiber transmission.
RS232
、
RS485,RS422 Serial interface
1) TX1, GND1 and RX1 are connected correspondingly to the RS232 launch, ground and receiving signal line in the first channel.
2) TX1, GND1 and RX1 are connected correspondingly to the RS232 launch, ground and receiving signal line in the second
channel.
Different functions in specific cases, the port function as follows
Function
Connection ports definition
Dual RS232model
TX1 GND(data
ground)
RX1 TX2 GND(data
ground)
RX2
Dual RS485 model
A2
SHIELD(shield ground)
B2
A1
SHIELD(shield ground)
B1
RS232+RS485model TX1 GND(data
ground)
RX1 A1 SHIELD(shield
ground)
B1
RS422 model
TX+
SHIELD(shield ground)
TX-
RX+
SHIELD(shield ground)
RX-
Remark: RS232+RS485 model, Channel 1 RS232, Channel 2 is RS485.
Wiring Connection
1.
Fiber connection methods: Cj-MF series belongs to single optical port device, suitable for point to point connection. As
shown in the figure below, the optical fiber must cross connection, namely the RX connect other side TX, and TX to RX
accordingly.
2. V+, V-, SHIELD respectively connect with anode, cathode of DC power supply and shielding ground.
DIN-Rail Installation
In order to use in industrial environments expediently, the device adopt 35mm DIN-Rail installation, the installation steps as
Current input channel equivalent circuit diagram Voltage input channel equivalent circuit diagram