background image

 

  

 BM5263 

OPERATOR’S    MANUAL

 

.    Introduction 

Welcome to use this product. 

   BM5263  adopts high-performance  MCU  processor,it  is   

 Great Value 

as  has  high 

reliability,security, automatically 

setting 

range 

funcition,hand-held clamp 

meter etc.. the 

product 

has 

large digital 

display, full range 

overload 

protection, data-hold  function, undervoltage  indication, auto  shut  off    function,it 
has TRUE 

RMS 

measurement 

function 

which 

 can 

accurately 

measure frequency voltage, non-sinusoidal voltage  and inrush  current measurement 
function  which  can  measure  inrush  current about  80mS  RMS,   the instrument is 
suitable  for  frequency-converting  power  supply,   motor  performance test,   The 
function  to  measure  DC  current range  up  to  DC 40A/400A/6000A , which is  widely 
used  in electroplating, DC  welding  machine, motor  vehical test and  all  kinds 
of DC 500mA current  measurement. It  is more  excellent for  a  new  generation  of 
practical electrical measuring instrument . 

    This  product  is  ideal  instrument  for  test, maintenance  and  repais  in  college, 

smelting, communications, manufacturing, petroleum, electric 

power, national 

defense,electronic, electric power equipment . 

. Safety standard

         

The  meter  in  structure  complies  with  the  safety  requirements  of  ICE61010-1.  Read 
the instruction carefully as follows before you use the meter: 
1.  When  measuring  voltage,  AC  or  DC  voltage  should  not  be  more  than  the  peak 
voltage (DC / AC 600V) of the meter.   
2. Voltage of less than 36V is safety voltage. When the voltage is more than DC 51V 
or  AC36V, the leads  should be checked. The test lead should be connected correctly 
and their insulating property should be under excellent status against electric shock.   
3. When change of functional measuring range, the test lead should be away from test 
point.     
4.It  is  suggested  that  for  safety  the  functions  and  range  should  be  selected  correctly 
although protective function for the full measuring range exists.   
5.When  measurement  of  current,  the  input  current  shouldn’t  be  more  than  the 
maximum current labeled on input end.   
6. Safety symbols: 

         

 

 

Warning! 

         

 

 

risk of high voltage and electric shock! 

         

 

 

Double insulated. 

. Features 

3.1      General   

3.1.1The  meter  is  based  on  CMOS  large  scale  IC  and  can  automatically  changed 
measuring  range for  measurement  of  AC/DC  voltage,  AC, resistance, frequency and 
capacity, which makes the meter easy to be used.   
3.1.2  Display mode: Display by LCD. 
3.1.3    Maximum display: 3999 
3.1.4  Maximum span of jaw: 30mm.   
3.1.5  Auto negative polarity indication: Displaying “-”.   

3.1.6 Lack of battery power: Displaying “

 

”.   

3.1.7 Auto power OFF 

  After  turning  on  the  instrument  and  without  turning  the  function  switch  or 

pressing any button, the instrument  will automatically enter into  sleep  mode after 10 
minutes,to save battery power.when it is in the sleep mode you can press the SELECT 
key  to  wake  up  the  instrument.  If  you  don't  need  the  automatic  sleep  mode,  you 
should  hold  down  the  DH  key  to  turn  on  the  instrument,  and  then    the  symbol" " 
will not be display on the LCD. 
3.1.8    Work environment: 0

C-40

C, 75%RH. 

3.1.9    Storage environment: -10

C-60

C, 85%RH. 

3.1.10    Battery 

9V

×

1(IEC6F22,NEDA1604 or JIS006P

 

3.1.11External dimensions: 195

L

)×

64

W

)×

35

H

mm 

3.1.12Weight: About 360g (including battery’s weight) 

3.2

 

Technical specifications

 

Accuracy

±(% r digit); calibration term is one year. 

Ambient temperature: 23

C±5

C;      Ambient humidity: 

70%RH 

3.2.1  DCV 

Range 

Accuracy 

Resolution 

Input impendance 

400mV 

0.1mV 

About 10MΩ 

4V 

1mV 

About 10MΩ 

40V 

10mV 

About 10MΩ 

400V 

 

±(0.8%+2d) 

 

100mV 

About 10MΩ 

600V 

±(1%+3d) 

1V 

About 10MΩ 

3.2.2 ACV 

Range 

Accuracy 

Resolution 

Input impendance 

400mV 

0.1mV 

About 10MΩ 

4V 

1mV 

About 10MΩ 

40V 

10mV 

About 10MΩ 

400V 

±(1.2%+5d) 

100mV 

About 10MΩ 

600V 

±(1.5%+5d) 

1V 

About 10MΩ 

Frequency

10Hz~1kHz (Warning

Frequency for square wave accuracy is specified 

from 10Hz to 400Hz)

display

TRUE RMS(sinusoidal waveform RMS calibration)

 

Overload protection:250V at mV range,DC1000V or peak value AC1000V at V range 

 
3.2.3 DCA 

Range

 

Accuracy

 

Resolution

 

40A 

10mA 

400A 

100mA 

600A 

 
±(2%+10d) 

1A 

3.2.4 ACA 

Range

 

Accuracy

 

Resolution

 

40A 

10mA 

400A 

100mA 

600A 

 
±(2%+10d) 

1A 

AC Conversion Type

  TRUE RMS responding, calibrated readings consistent with 

sinusoidal waveform RMS. Frequency Range:50~60Hz

 

3.2.5  Resistance 

 

Range 

Accuracy 

Resolution   

400

Ω

 

0.1

Ω

 

4k

Ω

 

1

Ω

 

40k

Ω

 

10

Ω

 

400k

Ω

 

100

Ω

 

4M

Ω

 

±(1%+3d) 

1k

Ω

 

40M

Ω

 

±(1.5%+5d) 

10k

Ω

 

Overload protection: effective value 220V 

3.2.6

 

Capacitance 

Range 

Accuracy 

Resolution   

10nF 

±(3%+20d) 

0.001nF 

100nF 

0.01nF 

1uF 

0.1nF 

10uF 

1nF 

100uF 

10nF 

1000uF 

 
 

±(3%+5d) 

100nF 

10mF 

±(5%+5d) 

1uF 

Overload protection: effective value 250V 
warning

There  is    about  20pF  dead zone  in  the  10nF,capacitance  below  20pF  can 

not be measured 

3.2.7  Frequency  

Range 

Accuracy 

Resolution

 

100Hz 

0.01Hz 

1kHz 

0.1Hz 

10kHz 

1Hz 

100kHz 

10Hz 

1MHz 

100Hz 

10MHz 

1kHz 

40MHz 

 
 
 

±(0.5%+3d) 

10kHz 

Overload protection: effective value 250V. Input sensitivity RMS: effective value 1V. 
NOTE:If  the  voltage  of  the  frequency  being  measured  is  above  30V,set  the  rotary 
function  switch  to  the  ACV  measured  function  and  press 

SELECT

key  to  enter 

voltage frequency measured function,in order to avoid demage the instrument. 

3.2.8

 

DUTY 

Rrange

 

Accuracy

 

Resolution

 

1%~99% 

±(0.5%+3d)

 

0.1% 

Overload protection: effective value 250V. 
input sensitivity RMS

1V 

3.2.9  

Forward voltage drop of diode

 

 

Displaying approximate forward voltage values of diode. Measuring condition: 

forward direct current is 1.5mA; opposite DC voltage is about 3 V.

 

3.2.10  

Continuity Test 

 

In  the  case  that  the  resistance  between  two  tested  points  is  less  than  about 
90

±20

,the buzzer will bring up sound. Test condition:Open-circuit voltage is 

about 0.5V.

 

Ⅳ.

Operation 

4.1  

Instruction for control panel

 

1

  jaws 

2

  Trigger 

3

Rotary  switch

This  switch  is  used  to  select  functions  such  as 

current.voltage,capacitance.resistance,temperature,frequency,forward  voltage  drop  of 
diode,continuity and turn on/off the meter. 

4

  “SELECT” button: When  press the key continuously, change the range of all 

function for a proper range you need. 

5

“RANGE” button: One may change the measuring range by pressing this button,   

press this key to cycle from small to large range of each function 

6

INRUSH:measuring Inrush voltage, current key,in AC measuring function press   

the key  2  seconds,  it  will   measure  the   Inrush   value, and  show  the  "INR" symbol 
in  the  LCD, INRUSH  function can  measure  current or  voltage  with  the minimum 
period  up  to   valid  values  80mS,in  the  inrush mode, instrument automatically  enter 

Reviews: