17
MAIN FEATURES
Operating frequency 868.150 MHz
Redundant transmission by radio command with selectionable transmission
time
Internal sensor and input for remote sensor
Possibility of locking or limiting the knob
Low battery indicator
Heating/Cooling selection can be managed by the thermostat or on the
receiver
TECHNICAL FEATURES
Power supply:
2 x 1.5V= alkaline AAA type batteries
Duration of the batteries:
>6 years at TX every 10 min
>2.5 years at TX every 3 min
>4 years at TX every 3 min with reduced
power
Measurement range:
-5.0°C ..+46.1°C
Regulation range:
6°C .. 30°C
Precision:
±1°C
Resolution:
0.1°C
Hysteresis:
defined on the receiver
Type of sensor:
NTC 100kΩ @ 25°C internal
Remote sensor:
NTC 100kΩ @ 25°C (optional)
Maximum length of the wires
to the remote sensor:
3 m
Frequency:
868.150 MHz
Output power (ERP):
< 25 mW
•
•
•
•
•
•