4.2.1.
Exerciser
The users can define CAN frame and send it through uCAN.
(Provides manual or automatic transmission mode)
Name
Description
TYPE
Type of CAN frame.
STD DATA: CAN Standard Data Frame
STD REMOTE: CAN Standard Remore Frame
EXT DATA: CAN Extended Data Frame
EXT REMOTE: CAN Extended Remote Frame
ID(Hex)
CAN frame ID (Hex Value)
Input Range: Standard = 0 ~ 7FF, Extended = 0 ~ 1FFFFFFF
DLC
DLC (Data Length Code) of a CAN frame
Input Range: 0 ~ 8 (Byte)
DATA(Hex)
CAN frame data (Hex Value)
Input Range: 0 ~ FF
Reset
Re-initialize configuration of TYPE, ID, DLC, and DATA
Send
Send one CAN frame with pre-configured TYPE, ID, DLC, and DATA.
Interval(ms)
When sending CAN frames automatically, interval can be set with
minimal unit value of milliseconds. (Input Range: 10 ~ 1000)
Auto
Sends CAN frame automatically, with pre-configured ID, DLC, and DATA.
Set
Apply changed ‘Interval’ value.
(Button enabled when the ‘Interval’ value is changed.)
Advanced
Mode
Enable additional mode for the Exerciser.
(For more information, please refer to the next page.)