_________________________________________________________________________________________________________
VR 300 ECV/B
Installation description
206552 (12-12-2012)
13
Systemair
AB
R = Red
B = Blue
Y = Yellow
Fig. 12
Connection to cooker hood
The VR 300 ECV/B is designed for connection to, and for operation from, special cooker hood.
When mounting the cooker hood underneath the ventilation unit the special plugs on the cooker hood are
connected to the corresponding plugs on the ventilation unit (
fig.13
).
For remote installation of the cooker hood, use fixed wiring by means of 2 pcs PFXPplastic cable 3x1,5
mm2 + earth or equal.
On the side of the cooker hood mount Ensto special plugs respectively type NAC31SH.W (3-pole)
and NAC41SH.W on the cables.
On the ventilation unit side mount Ensto special plugs NAC32SH.W and NAC42SH.W on the
cables.
(As an alternative to Ensto plugs, standard junction box can be applied).
Check the enclosed wiring diagram for more detailed information.
1
2
3
4
5
6
Position Description
1
Air handling unit VR 300 ECV/B
2 Cooker
hood
3
Ensto special plug, type NAC32SH. (230V 1~)
4
Ensto special plug, type NAC42SH.W (control signal 10VDC)
5
Ensto special plug, type NAC31SH.W (230V 1~)
6
Ensto special plug, type NAC41SH.W (control signal 10VDC)
Fig.13
Summary of Contents for VR 300 ECV/B
Page 1: ...A001 VR 300 ECV B 1000W 500W Air Handling Unit Installation description GB GB...
Page 2: ......
Page 17: ...A001 VR 300 ECV B 1000W 500W Luftbehandlingsaggregat Installationsbeskrivning GB SE...
Page 31: ...A001 VR 300 ECV B 1000W 500W Ventilasjonsaggregat Montasjeanvisning GB NO...
Page 44: ...Rett til endringer forbeholdes Produsent www systemair no...
Page 45: ...A001 VR 300 ECV B 1000W 500W L ftungsger t Installationsanweisung GB DE...
Page 58: ...A001 RU VR 300 ECV B 1000 500 GB RU...
Page 59: ...RU...