background image

 

 

  

  

                                                                                                                                   Corrigo ver. no. 1.2-1-00 

 

 

 

 

Topvex SX03, SX04, SX06 

Compact Air Handling Unit 

 
 
 

 
 
 

 

 
 

 
 

 

 

 
 
 
 
 

 

Installation description

  

GB  

  

GB 

Summary of Contents for Topvex SX03 EL

Page 1: ...Corrigo ver no 1 2 1 00 Topvex SX03 SX04 SX06 Compact Air Handling Unit Installation description GB GB...

Page 2: ...f machinery Basic concepts general principles for design Part 1 Basic terminology methodology EN ISO 12100 2 Safety of machinery Basic concepts general principles for design Part 2 Technical principle...

Page 3: ...ments Table of contents Declaration of Conformity 2 Introduction 3 Table of contents 3 Dimensions and weight 4 Topvex SX03 4 Topvex SX04 SX06 5 Component description Topvex SX 6 Transport and storage...

Page 4: ..._______________________________________________________________ Topvex SX03 SX04 SX06 Installation description Original 205871 4 Systemair AB Dimensions and weight 62 375 470 106 1320 750 1600 43 43 1...

Page 5: ...4 mm Topvex SX06 mm A 800 800 B 500 600 C 250 300 D 187 180 E 167 167 F 150 100 G 1041 1127 H 171 164 I 183 183 J 30 30 K 1747 2000 L 520 520 X 355 410 Y 212 204 Z 106 106 Topvex SX04 SX06 Topvex SX04...

Page 6: ...9 10 11 12 3 4 5 6 11 10 8 13 Fig 3 Model M N mm Topvex SX03 500 630 Topvex SX04 500 698 Topvex SX06 550 824 Description 1 Connection supply air 2 Connection extract air 3 Connection outdoor air 4 Con...

Page 7: ...into operation Fig 4 Place the unit preferably in a separate room e g storage room laundry room attic or similar The electronic components should not be exposed to lower temperature than 0 C or highe...

Page 8: ...stalled in a non heated place the drain pipe and trap needs to be insulated well to prevent the water from freezing L 32 mm Fig 5 Fig 6 H mm Max negative pressure Pa 85 500 110 750 135 1000 Table 1 No...

Page 9: ...t must not be put into operation before all the electrical safety precautions have been read and understood See fig 3 where to find the electrical connection box See page 10 and 11 and the enclosed wi...

Page 10: ...reference 10 DO5 Alarm output for all alarms 24V AC Max 2 0 A continuous load 11 AI Ref Sensor supply air reference 12 AI 1 Sensor supply air These inputs may only be wired to voltage free contacts To...

Page 11: ...he unit from factory The supply air sensor is enclosed in the package upon delivery Timer extended forced running When the unit is in shut down mode or running on low or medium speed it can be forced...

Page 12: ...or B alarm Function sketch Accessories dashed components Designation Component description DO Damper outdoor air DEH Damper exhaust air WCB Water cooling battery WVA Water valve actuator Fig 7 The im...

Page 13: ...et in the control panel The electric heating coil has both automatic and manual overheating protection The manual overheating protection which is controlled by the emergency thermostat is reset by pre...

Page 14: ...mary circuit Fig 9 Control panel The SCP control panel is delivered with a 10m cable that is pre connected to the panel and with a fast coupling ISDN contact pre connected to the Topvex unit The ISDN...

Page 15: ...n is at the root of the menu tree Pressing DOWN will move you through the menu choices at this the lowest level UP will move you back through the choices To enter a higher menu level use UP or DOWN to...

Page 16: ...he right to make changes and improvements to the contents of this manual without prior notice Systemair AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www sy...

Reviews: