4.2 Technical data

4.2.1 Dimensions and weights Topvex SoftCooler TR09-TR15

Fig. 1 Dimensions (mm) TR09-TR15 (Drawn as left hand unit)

Model

AA

B

C

D

E

F

G

I

J

K

L

TR09

2630

1630

1120

810

895

104

129

129

105

210

700

TR12

2770

1740

1230

930

965

76

104

104

105

215

800

TR15

2820

1980

1470

1180

965

76

104

104

105

236

1000

Model

M

N

O

P

Q

R

S

Weight,

kg

Total Weight, kg

1

TR09

300

190

1030

870

840

550

120

260

765

TR12

350

185

1140

940

840

500

135

290

870

TR15

350

185

1380

940

890

550

135

345

1055

1.

Incl. air handling parts

Topvex SoftCooler TR09-15

Installation instructions

208767

4

Systemair Sverige AB

Summary of Contents for Topvex SoftCooler TR Series

Page 1: ...Topvex SoftCooler TR09 15 Installation instructions Document in original language 208767 EN_GB 15 03 2016 A004...

Page 2: ...here how to install 7 6 3 Installing the unit 8 6 3 1 Installation 8 6 3 2 Installation procedure 10 6 4 Dividing the Topvex TR air handling unit 11 6 4 1 Assembly the Topvex SoftCooler 12 6 4 2 Elect...

Page 3: ...inery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements EN 60335 1 Household an...

Page 4: ...arm water and wash for 20 minutes visit a doctor The units electrical connection to the mains supply must be preceded by an all pole circuit breaker with a minimum 3 mm gap Caution If the unit is inst...

Page 5: ...ic information and recommendations concerning the design installation start up and operation to ensure a proper fail free operation of the unit The key to proper and safe operating of the unit is to r...

Page 6: ...105 210 700 TR12 2770 1740 1230 930 965 76 104 104 105 215 800 TR15 2820 1980 1470 1180 965 76 104 104 105 236 1000 Model M N O P Q R S Weight kg Total Weight kg1 TR09 300 190 1030 870 840 550 120 26...

Page 7: ...hand connected units Position Description 1 Compressor 2 Condenser coil 3 Evaporator coil 4 Filter drier with sight glass 5 Expansion valve 6 Drip tray with drain 7 Water seal 8 Cable grommet for exte...

Page 8: ...rminal block mains supply 2 Circuit breaker MCB oil heaters 3 Relays 4 Terminal block internal external connections 5 Frequency converter with display 6 DC Choke 7 Transformer 24 V 8 Display Topvex So...

Page 9: ...or indoor installation Place the unit on a horizontal flat surface It s important that the unit is completely levelled before it is put into operation The electronic components should not be exposed t...

Page 10: ...t Position Description Supply air Exhaust air Outdoor air Extract air 1 VAV Pressure transmitters accessory 2 Damper and motor outdoor air accessory 3 Damper and motor exhaust air accessory 4 Locked c...

Page 11: ...door air Extract air 1 Exhaust air By pass 2 VAV Pressure transmitters accessory 3 Damper and motor outdoor air accessory 4 Damper and motor exhaust air accessory 5 Damper and motor exhaust air by pas...

Page 12: ...aker safety switch which is enclosed inside the unit on delivery The wiring between the safety switch and the unit is led through the top of the unit casing directly to the electrical connection box S...

Page 13: ...plit the unit Remove the heat exchanger extract fan and the extract air filter A Remove the plate B Loose the cable connectors C Remove the 7 M10 screws that join the two halves of the appliance Fig 6...

Page 14: ...ex SoftCooler have been joined together with the two air handling unit parts it is in total 5 duct connections on top of the unit Outdoor air Supply air Extract air and 2 Exhaust air Duct connections...

Page 15: ...ing The unit is not to be taken into operation before the included condensation drain and water seal are connected from the Topvex SoftCooler to the floor drain The drain is to be connected to the dra...

Page 16: ...ee also the chapter Internal electrical connections 3 Move the Exhaust air temp sensor EHS located at the extract air filter from its place to the new place by the label EHS in the SoftCooler Fig 10 E...

Page 17: ...tion Remark G G 24V AC 4 DI ref Referens 10 DO ref Referens 12 DO Exhaust air damper A signal from control unit E28 is lead via the relay R2 to terminal 28 for controlling of the by pass damper access...

Page 18: ...Description EF Extract air fan SF Supply air fan SS Temp sensor supply air OS Temp sensor outdoor air ETS Temp sensor extract air EHS Temp sensor exhaust air UC Controller E28 RC Rotor control RM Rot...

Page 19: ...3 Power control The compressor CPR are step less controlled between in the frequency converter FC set minimum and maximum frequency 7 4 Power limitation The frequency converter FC is continuously sens...

Page 20: ...nected via the Safety switch see chapter 6 4 2 Electrical connection By pass damper connected when such is to be used accessory see chapter 6 4 2 1 External Internal connections Internal operating cab...

Page 21: ...on the compressor the oil in the compressor crankcase must be heated before the first start Moment Done Note Stop the Supply and extract fan via the Topvex air handling units safety switch Turn on the...

Page 22: ...or running Read the below values via the display of the frequency converter see section Frequency converter quick guide in Operating and Maintenance Instructions First set the parameter for reading th...

Page 23: ...Topvex SoftCooler TR09 15 Installation instructions 208767 21 Systemair Sverige AB...

Page 24: ...erves the right to make changes and improvements to the contents of this manual without prior notice Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 22...

Reviews: