Warnings

2

Warnings

The following admonitions will be presented in the different sections of the document:

Danger

• Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or

serious injury.

Warning

• Indicates a potentially hazardous situation that may result in minor or moderate injuries.

Caution

• Indicates a risk of damaging the product or prevent optimal operation.

Important

• This appliance can be used by children aged from 8 years and above and persons with reduced physical,

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.

• Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children

without supervision.

3

Product information

3.1

General

This installation manual concerns air handling unit type Topvex SF manufactured by Systemair Sverige AB. The units in-
clude the following model options:

Model:

Topvex SF02, Topvex SF03, Topvex SF04, Topvex SF06, Topvex SF08 and Topvex SF12.

Heating coil: EL

(Electric),

HWL

(Water coil, low power),

HWH

(Water coil, high power).

• Stepless voltage control. VAV available as accessory (VAV– Variable Air Volume = Constant duct pressure control).

This manual consists of basic information and recommendations concerning the design, installation, start-up and opera-
tion, to ensure a proper fail-free operation of the unit.

The key to proper and safe operating of the unit is to read this manual thoroughly, use the unit according to given
guidelines and follow all safety requirements.

130324 | A004

Summary of Contents for Topvex SF Series

Page 1: ...Document in original language 130324 A004 Topvex SF02 SF12 Air Handling Unit Installation instructions GB...

Page 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...l 6 4 3 Installing the unit 7 4 3 1 Mounting brackets 8 4 3 2 Installing procedure 8 4 4 Connection 9 4 4 1 Ducting 9 4 4 2 Electrical connection box components 10 4 4 3 External connections 11 4 4 4...

Page 4: ......

Page 5: ...12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower li...

Page 6: ...d Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 Product information 3 1 General This installation manual concerns air han...

Page 7: ...B 46 46 E C 63 D E J G I H 22 W Fig 1 Topvex SF02 Topvex SF03 Dimension mm Model A B C D E F Topvex SF02 1463 557 321 161 278 1366 Topvex SF03 1550 619 373 187 310 1454 Model G H I J W Weight kg Topve...

Page 8: ...3 200 400 89 Topvex SF06 1497 849 441 250 500 94 Topvex SF081 1497 903 545 300 600 125 Topvex SF121 1546 1011 545 400 700 74 1 size S08 and S12 only in HW Model G H I J K W Weight kg Topvex SF04 175 1...

Page 9: ...9 3x16 Topvex SF02 HWL HWH 168 10 Topvex SF03 EL 7 7 kW 169 7 7 3x16 Topvex SF03 EL 15 3 kW 169 15 3 3x25 Topvex SF03 HWL HWH 169 10 Topvex SF04 EL 10 5 kW 540 10 5 3x20 Topvex SF04 EL 20 9 kW 540 20...

Page 10: ...the ordered equip ment must be reported to the supplier of Systemair products 4 2 Where how to install Topvex SF02 SF12 can be installed outside if weather protected An outdoor air section ODS is ava...

Page 11: ...horizontally on a wall always make sure that the water pipe connections are above the battery so the HW battery can be properly de aired By unscrewing four screws the HW battery can easily be rotated...

Page 12: ...here the unit is to be mounted Make sure that the surface is flat levelled and that it carries the weight of the unit Perform the installation in accordance with local rules and regulations 2 Lift the...

Page 13: ...utdoor air 9 Duct connection supply air Note Duct connections duct ends should be covered during storage and installation Grilles for intake roof units must be installed according to building regulati...

Page 14: ...down if the unit is false ceiling mounted Topvex SF is equipped with a built in regulator and internal wiring Loosen the 4 screws to remove the hatch to the electrical connection box Fig 6 Connection...

Page 15: ...ransmitter extract air 422 UAI 2 UDI 2 Pressure transmitter supply air 44 UAI 3 UDI 3 Frost protection sensor water heating battery Use terminal 40 as reference 43 DI ref External function reference 2...

Page 16: ...rolled in two ways Use the pre configured digital output to activate the extract fan DO 5 The output is active when the supply fan in the unit is running Table 1 From External connection 10 DO ref DO...

Page 17: ...heater The heating coil is located after the fan and the material is stainless steel The electrical heating coil has both automatic and manual overheating protection The power demand of the electrica...

Page 18: ...ction on the controller 6 Control panel 6 1 General information The control panel is delivered connected to the Corrigo control unit situated in the electrical connection box Cable length is 10 m In c...

Page 19: ...Control panel 15 6 2 Dimensions Fig 9 Control panel dimensions Position Dimensions mm A 115 0 B 94 0 C 26 0 D c c 60 0 E 50 5 130324 A004...

Page 20: ...connections Position Description 1 Mounting holes 2 Connection block 3 Connection to brown cable 4 Connection to yellow cable 5 Connection to white cable 6 Connection to black cable 6 4 Additional equ...

Page 21: ...Control panel 17 130324 A004...

Page 22: ...18 Control panel 130324 A004...

Page 23: ...130324 A004...

Page 24: ...Topvex SF02 SF12 Installation instructions 130324 en_GB 02 10 2018 A004 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com...

Reviews: