installation manual 

2.    ATTACHED FITTINGS 

Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully.  

QUANTITY 

INSTALLATION FITTINGS 

SHAPE 

NAME 

1. Outdoor unit installation manual 

2. Outdoor unit owner’s manual 

3. Indoor unit owner’s manual 

4.Outflow connecting tube 

An insufficient power supply capacity or inappropriate installation  
may cause fire. 

Use the specified cables for wiring connect the terminals  
securely fix. To prevent external forces applied to the terminals 
from affecting the terminals.  
Be sure to provide grounding. 

Do not connect ground wires to gas pipes, water pipes, lightning rods  
or ground wires for telephone cables. 

Conform to the regulations of the local electric company when  
wiring the power supply. 

Inappropriate grounding may cause electric shock. 

Do not install the air conditioner in a location subject to a risk  
of exposure to a combustible gas. 

If a combustible gas leaks, and stays around the unit, a fire may occur. 

 

6)  Reamer
7)  Gas leak detector
8)  Tape measure
9)  Thermometer
10) Mega-tester
11) Electro circuit tester
12) Hexagonal wrench
13) Flare tool
14) Pipe bender
15) Level vial
16) Metal saw
17) Gauge manifold (Charge hose:R410A special requirement)
18) Vacuum pump (Charge hose:R410A special requirement)
19) Torque wrench 
                  1/4(17mm)16N•m (1.6kgf•m)
                  3/8(22mm)42N•m (4.2kgf•m)
                  1/2(26mm)55N•m (5.5kgf•m)
                  5/8(15.9mm)120N•m (12.0kgf•m)
20) Copper pipe gauge adjusting projection margin
21) Vacuum pump adapter

 Required tools for installation work 

1)  Philips screw driver                     
2)  Hole core drill(65mm) 
3)  Spanner 
4)  Pipe cutter 
5)  Knife  

   Refrigerant Piping 

Piping kit used for the conventional refrigerant cannot be used.
Use copper pipe with 0.8 mm or more thickness for φ9.5.
Use copper pipe with 1.0 mm or more thickness for φ15.9.
Use copper pipe with 1.0 mm or more thickness for φ19.0.
Flare nut and flare works are also different form those of the 
conventional refrigerant.take out the flare nut attached to the main
unit of the air conditioner, and use it.
   

Before installation

Be careful to the following items before installation.

   Air purge

For air purge, use a vacuum pump.
Do not use refrigerant charged in the outdoor unit for air  purge. 
(The refrigerant for air purge is not contained in the outdoor unit.)

   Electrical cabling 

Be sure to fix the power cables and indoor/outdoor  connecting  
cables with clamps so that they do not contact with the cabinet, etc. 

   Installation Place 

A place which provides a specified space around the outdoor unit.
A place were the operation noise and discharged air are not given
to your neighbors. 
A place that is not exposed to a strong wind.
A place that does not block a passage.
When the outdoor unit is installed in an elevated position, make
sure it's four feet securely installed.
There must be sufficient space for carrying in the unit.
A place where the drain water does not make any problem.

Strong
wind

Strong
wind

2000

Fig.2-2 

Fig.2-1 

      When  installing  the  outdoor  unit  in  a  place  that  is  constantly 
exposed to a strong wind such as the upper stairs or rooftop of a 
building,  apply  the  windproof  measures  referring  to  the  following 
examples.
      Install the unit so that its discharge port faces to the wall of the 
building.  Keep  a  distance  of  2000mm  or  more  between  the  unit 
and the wall surface.

CAUTION 

   Install the outdoor unit at a place where discharge air is not blocked. 
   When an outdoor unit is installed in a place that is always exposed  
   to a strong wind like a coast or on a high storey of a building, secure  
   a normal fan operation by using a duct or a wind shield. 

      Supposing the wind direction during the operation season of the 
 discharge port is set at right angle to the wind direction. 

Summary of Contents for SYSVRF AIR EVO HP Mini

Page 1: ...Outdoor unit Mini VRF Heat Pump INSTALLATION MANUAL GB SYSVRF AIR EVO HP Q R ...

Page 2: ...intain the air conditioner Inappropriate installation may result in water leakage electric shock or fire Turn off the main power supply switch or breaker before attempting any electrical work Make sure all power switches are off Failure to do so may cause electric shock Connect the connecting cable correctly If the connecting cable is connected in a wrong way electric parts may be damaged When mov...

Page 3: ...se copper pipe with 1 0 mm or more thickness for φ15 9 Use copper pipe with 1 0 mm or more thickness for φ19 0 Flare nut and flare works are also different form those of the conventional refrigerant take out the flare nut attached to the main unit of the air conditioner and use it Before installation Be careful to the following items before installation Air purge For air purge use a vacuum pump Do...

Page 4: ...ion place Near a private power station or high Frequency equipment The insulation of the metal parts of the building and the air conditioner should comply with the regulation of National Electric Standard Install indoor unit outdoor unit power cord and connecting wire at least 1m away from TV set or radio to prevent noise or picture interference 3 2 Installation space Unit mm 300 600 300 2000 Wall...

Page 5: ... the bends meet the following requirements 4 1 Refrigerant piping Fig 4 1 Large pipe Four condensed water outlets on the chassis for selection display as the follow figure Please pay attention to avoid the components while connect to the connecting pipes While installing the outdoor unit pay attention to the installation place and the drainage pattern if it s installed at the alpine zone the froze...

Page 6: ...units Main pipe size mm Iiquid pipe Branch Pipe 4 1 4 1 R410A Indoor unit connecting pipes diameters 1 R410A Indoor unit connecting pipes diameters 4 3DŽ 2 Example 1 In the Fig 4 5 The downstream inner units of the L2 and its total capacity is 28 2 56ˈrefers to the Table 4 4 the air liquid side of L2 is Φ15 9 Φ9 5DŽ 1 1 1 1 1 1 D E F H I G The straight distance between copper pipe turning and the co...

Page 7: ...door unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensure the effectiveness of machine and then try to open the indoor units at different time When the capacity of indoor unit is greater than or equal to 16 8kW the caliber of primary gas pipe should be augmented from Φ16 to Φ19 12 7 Flaring nut A 45 R410A A 56 6 4 Flaring nut 15 9 Flaring ...

Page 8: ...e capacity is decreasing it still can increase the gas side main pipe size ŏ Pδ N θ N ε ŏ Pδ N θ N ε Inner branch pipes are a f the size selection please refers to Table4 6 Note The max length of the branch pipe should not longer than 15m Indoor unit branch pipe The main pipes of indoor unit and the indoor unit branch pipe components The downstream inner units of the main pipe L2 are N1 N2 and its...

Page 9: ...frigerant Amount to be Added Using vacuum pump to do the vacuum never using refrigerant to expel the air Vacuuming should be done from both liquid side and gas side simultaneously Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit indoor unit connection NOTE Additional refrigerant volume of divergent pipe is 0 1kg per item Consider ...

Page 10: ...or unit Indoor unit Indoor unit Signal wire between indoor units 1 3 4 1 4 3 1 1 4 3 4 3 Branch Box Branch Box CCM Branch Box Please use 3 core shielded wire and connect the shielded layer to Grounding Power Supply Power Supply CCM For 8 18kW Fig 5 3 Outdoor Unit Indoor Unit Power wiring indoor Communication Bus Power 220 240V 50Hz 1 Phase 208 230V 60Hz 1 Phase Power 220 240V 50Hz 1 Phase 208 230V...

Page 11: ...on is indicated in broken line table users can select it when necessary CAUTION Indoor Outdoor Unit Signal Wire Connect the wire according to their numbers For 10 5 18kw Fig 5 4 Outdoor Unit Indoor Unit Power 220 240V 50Hz 1 Phase 220 240V 60Hz 1 Phase 208 230V 60Hz 1 Phase Power wiring indoor Communication Bus Indoor Unit Indoor Unit wire distribution box Switch Circuit breaker Switch Circuit bre...

Page 12: ...work address of indoor units NOTE Single phase indoor unit Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary In broken line table users can purchase the wire controller when necessary To wire controller Display board WHITE BLUE BLACK P Q X Y E YELLOW GRAY To Outdoor COMM BUS To Central Control Monitor CCM COMM...

Page 13: ...ition 2 Calculate the indoor cubage B m as the minimum cubage 3 3 Calculate the refrigerant amount İ critical amount Counter measure against high amount 1 Install mechanical ventilator to keep the refrigerant amount under critical level ventilate regularly 2 Install leak alarm facility related to mechanical ventilator if you can not regularly ventilate b Leak alarm related to mechanical ventilator...

Page 14: ...202000171943 MDV12I 013IW SYSVRF AIR EVO HP Q R_IM April 2014 ...

Reviews: