SystemAir SysLoop 15 Installation And Maintenance Manual Download Page 44

XII SysLoop

APPENDIX / ANNEXE / ANLAGE / ALLEGATO / ANEXO

LEGEND

English

Fr

ançais

Deutsch

Italiano

Español

DESCRIP

TION

DESIGNA

TION

BEZEICHNUNG

DENO

MINAZIONE

DESCRIPCIÓN

FFG

Fuse  t

e F

uses (

no

t supplied 

or

 op

tion

)

Port

e-fu fusibles (

non f

ourni 

ou op

tion

)

Sicherungshalt

er

 + 

Schmelzsicherungen (

nich

t gelie

fert 

oder

 Op

tion

)

port

afu F

usibili (

non f

orniti o 

op

zione

)

port

afu F

usibles (

no incluidos 

u opción

)

QG

Cir

cuit br

eak

er

 (no

t supplied or

 

op

tion

)

Disjonct

eur

 (non-f

ourni ou op

tion

)

Of

enschalt

er

 (nich

t gelie

fert oder

 

Op

tion

)

In

terrutt

or

e f

orno (

non f

orniti o 

op

zione

)

Dis

yun

tor

 (no incluidos u opción

)

H1 

Seeing "under

 tension"

Vo

yan

t sous t

ension

sieh

t "un

ter

 Spannung"

Vedendo "so

tt

o t

ensione"

Viendo "bajo t

ensión"

HD 

Seeing "f

ault r

eporting"

Vo

yan

t de dé

faut

sieh

t "F

ehler

-Berich

t"

Vedendo "r

apport

o di c

olpa"

Viendo "r

eport

aje de de

fect

o"

K1

Re

friger

ation c

ompr

es

sor

 rela

y

Relais c

ompr

es

seur

 frigorifique

Relais der

 K

ält

emitt

el

kompr

es

sor

Relè del c

ompr

es

sor

e frigorif

er

o

Relé de los c

ompr

esor

 frigorífic

o

C1

Re

friger

ation c

ompr

es

sor

Compr

es

seur

 frigorifique

Kält

emitt

el

kompr

es

sor

Compr

es

sor

e frigorif

er

o

Compr

esor

 frigorífic

o

R1

Re

friger

ation c

ompr

es

sor

 cr

ank

case 

heat

er

Résis

tanc

e cart

er

 du c

ompr

es

seur

Ölsump

fheizungen der

 

Kält

emitt

el

kompr

es

sor

Resis

tenz

e del cart

er

 del 

compr

es

sor

e frigorif

er

o

Resis

tencias de cárt

er

 de los 

compr

esor

 frigorífic

o

FT

Ext

ernal s

af

ety

 compr

es

sor

Sécurit

é e

xt

erne c

ompr

es

seur

Ext

ern 

Sicherheits

vorrich

tungen v

on 

Kompr

es

sor

Sicur

ezza es

terna del c

ompr

es

sor

e

Seguridad e

xt

erna del c

ompr

esor

LP

Aut

oma

tic r

ese

t L

ow

 Pr

es

sur

pr

es

sos

ta

t

Pr

es

sos

ta

t bas

se pr

es

sion à 

armemen

t aut

oma

tique

Nieder

druckpr

es

sos

ta

t mit 

sel

bs

tt

ätiger

 Wieder

einschaltung

Pr

es

sos

ta

to bas

sa pr

es

sione c

on 

riarmo aut

oma

tic

o

Pr

esos

ta

to de baja pr

esión c

on 

re

arme aut

omá

tic

o

HP

Aut

oma

tic r

ese

t High Pr

es

sur

pr

es

sos

ta

t

Pr

es

sos

ta

t haut

e pr

es

sion à 

armemen

t aut

oma

tique

Hochdruckpr

es

sos

ta

t mit 

sel

bs

tt

ätiger

 Wieder

einschaltung

Pr

es

sos

ta

to alt

a pr

es

sione c

on riarmo 

aut

oma

tic

o

Pr

esos

ta

to de alt

a pr

esión c

on 

re

arme aut

omá

tic

o

CC

1

C1 c

ompr

es

sor

 condenser

 (single 

phase models

)

Condens

at

eur

 du c

ompr

es

seur

 C1 

(modèles monophasés

)

Kondens

at

or

 v

on K

ompr

es

sor

 C1 

(Einphasenmodel

le

)

Condens

at

or

e del c

ompr

es

sor

e C1 

(model

li mono

fase

)

Condens

ador

 del c

ompr

esor

 C1 

(modelos mono

fásic

os

)

RV

1

w

ay

 v

alv

e f

or

 c

ycle in

ver

sion

Vanne 4 

voies d’in

ver

sion de c

ycle

4-

W

ege

-Umk

ehrv

en

til für

 

thermodynamisches Heiz

en

Valv

ola 4 

vie di in

ver

sione di ciclo

Válvula de 4 

vías de in

ver

sión de 

ciclo

SW

De

tect

or

 o

f c

ondensed 

w

at

er

 le

vel

tect

eur

 de niv

eau d’

eau de 

condens

ation

De

tekt

or

 des 

W

as

ser

st

andes der

 

Ver

damp

fung

Riv

ela

tor

e di liv

el

lo d’

ac

qua di 

condens

azione

De

tect

or

 de niv

el de agua de 

condens

ación

IF

Tr

ea

ted air

 fan mo

tor

Mo

teur

 de 

ven

tila

tion air

 tr

ait

é

Lüft

ermo

tor

 Z

uluft

Mo

tor

e di 

ven

tila

zione aria tr

att

at

a

Mo

tor

 de 

ven

tilación air

e tr

at

ado

Y1

W

at

er

 cir

cuit b

y-pas

s v

alv

e (

no

supplied

)

Vanne b

y-pas

s cir

cuit d’

eau (

non 

fournie

)

Bypas

s-

Ven

til W

as

serkr

eislauf 

(nich

gelie

fert

)

Valv

ola b

y-pas

s cir

cuit

o del

l’ac

qua 

(non f

ornit

a)

Válvula b

y-pas

s del cir

cuit

o de agua 

(no incluida

)

FS

Flo

w

 s

wit

ch (

op

tion

)

Flo

w

 s

wit

ch (

op

tion

)

Str

ömungs

schalt

er

 (Op

tion

)

Flus

sos

ta

to (

op

zione

)

Conmut

ador

 de f

lujo (

opción

)

SM1

ON/

OFF s

wit

ch

In

terrup

teur

 mar

che

/arr

êt

Ein / 

Aus – Schalt

er

In

terrutt

or

e On/

Off

In

terrup

tor

 de mar

cha

/par

ada

SS

/W

Summer

/winer

 s

wit

ch (

closed in 

win

ter

) (

no

t supplied

)

In

terrup

teur

 é

/hiv

er

 (f

ermé en 

hiv

er

) (

non f

ourni

)

Win

ter

/Sommer

-Schalt

er

 (im Win

ter

 

geschlos

sen

) (

nich

t gelie

fert

)

In

terrutt

or

e es

ta

te

/in

verno (

chiuso in 

in

verno

) (

non f

ornit

a)

In

terrup

tor

 de in

vierno

/v

er

ano 

(c

err

ado en in

vierno

) (

no incluida

)

CW

Windo

w

 con

tact s

wit

ch

Con

tact de f

enê

tre

Fens

terk

on

takt

Con

ta

tt

o di fines

tr

a

Con

tact

de v

en

tana

T1

Tr

ans

former

 230V

/24V

Tr

ans

forma

teur

 230V

/24V

Tr

ans

forma

tor

 230V

/24V

Tr

as

forma

tor

e 230V

/24V

Tr

ans

formador

 230V

/24V

FFT

Fuse t

e fuse 1A

Port

e-f fusible 1A

Sicherungs Sicherung 1A

Port

afu fusibile 1A

Terminal de f fusible 1A

RC

POL822

Local c

on

trol module

Rappel de c

ommande local

Fernbedienung 

mit T

hermos

ta

t

Richiamo di c

omando locale

M

ando secundario local

ICT

An

ti-fr

ee

zing pr

ot

ection sensor

Sonde an

ti-

givr

e

Fr

os

tschutzt

emper

aturfühler

Sonda an

tibrina

Sonda an

tiescar

cha

RAT

Air

 temper

atur

e sensor

Sonde de t

empér

atur

e d’

air

Luftt

emper

aturfühler

Sonda di t

emper

atur

a del

l’aria

Sonda de t

emper

atur

a de air

e

LW

T

Outle

t w

at

er

 temper

atur

e sensor

Sonde de t

empér

atur

e de sortie 

d’

eau

W

as

ser

aus

tritts

temper

aturfühler

Sonda di t

emper

atur

a d’

uscit

d’

ac

qua

Sonda de t

emper

atur

a de s

alida de 

agua

Summary of Contents for SysLoop 15

Page 1: ...Water source heat pump Installation and maintenance manual 435 â 525 m3 h 1 51 â 2 90kW 1 93 â 3 68kW 15 30 SysLoop ...

Page 2: ......

Page 3: ...INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACIÓN English Français Español Deutsch Italiano ...

Page 4: ...TY 15 13 2 RECOMMENDATIONS FOR HYDRAULIC CONNECTIONS 16 13 3 RECOMMENDATIONS FOR CLEANING AND FLUSHING OUT THE SYSTEM 18 14 WIRING DIAGRAM AND LEGEND 19 14 1 WIRING DIAGRAM 19 14 2 LEGEND 19 14 2 1 POWER SUPPLY 19 14 2 2 PRESSOSTATS SETTING 19 15 ELECTRICAL CONNECTIONS 19 15 1 GENERALITIES 20 15 2 REMOTE CONTROL 20 15 2 1 WALL MOUNTING 20 15 2 2 ELECTRICAL CONNECTIONS 21 16 REGULATION 22 16 1 ORDE...

Page 5: ...n order to become fully familiar with the appliance we suggest to read also our Technical Instructions The information contained in these Instructions are subject to modification without advance notice 1 2 WARNING Follow the safety rules in forces when you are working on your appliance The installation commissioning use and maintenance of these units should be performed by qualified personnel havi...

Page 6: ...on in the atmosphere shall be kept at the minimum value and anyway below the occupational limits Since vapours are heavier than air and they tend to stagnate and to build up in closed areas any opening for ventilation shall be made at the lowest level Breathing protection In case of doubt about the actual concentration wear breathing apparatus It should be self contained and approved by the bodies...

Page 7: ...eck all the elements against the shipping documents in order to ensure that all the crates and boxes have been received Inspect all the units for any visible or hidden damage In the event of shipping damage write precise details of the damage on the shipper s delivery note and send immediately a registered letter to the shipper within 48 hours clearly stating the damage caused Forward a copy of th...

Page 8: ... greenhouse gas expressed in weight kg and CO2 equivalent Quantity of gas amount of gas contained in the machine in kg see ID plate GWP GlobalWarming Potential of the gas contained in the machine see ID plate GWP for the R410A 2088 GWP for the R407C 1774 7 3 1 CALCULATING GREENHOUSE GAS QUANTITIES 1 Installation servicing maintenance as well as checking the sealing must be carried out by qualified...

Page 9: ...ntion to the minimum water flow rate Caution 7 SysLoop 8 TECHNICAL SPECIFICATIONS 8 1 OPERATING LIMITS This equipment is designed EXCLUSIVELY for INDOOR installation In general sheltered locations such as garages roof space etc do not provide sufficient protection against extreme temperatures and or humidity and may be harmful to the unit s performance reliability and service life 8 1 1 ENVIRONMEN...

Page 10: ...having removed the packing box take out the suspension kit that is to be found inside the fan outlet frame 5 Before installing the unit check its height in relation to the available free ceiling height 6 Take particular care over the location and routing of the water pipes and the condensate drainage pipe as well as the electrical wiring The location and routing of these items must be clearly indi...

Page 11: ...a siphon on the condensates drainage pipe Do not install the unit on top of pipe work 4 Each unit is suspended from the ceiling on four threaded rods The rods are attached through the shock mounts to the corners of the unit by suspension angle brackets Warning Do not use rods of a diameter smaller than that stated below The rods must be solidly anchored to the ceiling and to the ceiling joists 5 E...

Page 12: ...he duct size to that of the unit s connection collar In the event of using metal ducts only the sides of the elbow section and all the spur duct sections should be covered with fibreglass sound insulation for reducing the noise level Fibreglass duct panels are more sound absorbent and may enable the flexible canvas connection to be eliminated The duct network must be laid out to avoid any rectilin...

Page 13: ... AIR FILTER 225X366X23 RETURN AIR INTAKE IN LINE RETURN AIR INTAKE REAR IN LINE BLOWING STANDARD CONFIGURATION AIR FILTER 366X225X23 REAR BLOWING FRESH AIR INTAKE Ø100 or Ø125 option 11 SysLoop 11 1 AIR BLOWING FRAME AND RETURN AIR INTAKE FRAME 11 2 AIR BLOWING PLENUM AND RETURN AIR INTAKE PLENUM ...

Page 14: ...xceeding the appliance s operating limits It is also common practice to shut down ventilation during periods of inoccupation night time setting of the set temperature Each appliance s ventilation system is generally a sub system within the building with its own distribution duct network The simple introduction of outdoor air into each return air plenum quite close to the unit s return air intake i...

Page 15: ...le pressure Pa LS MS HS Ductwork curve 0 100 200 300 400 500 600 700 800 0 20 40 60 80 100 120 140 2V 3V 4V 5V 6V 7V 8V 9V 10V Air flow m3 h Available pressure Pa LS MS HS Ductwork curve 0 100 200 300 400 500 600 700 800 0 20 40 60 80 100 120 140 2V 3V 4V 5V 6V 7V 8V 9V 10V Air flow m3 h Available pressure Pa LS MS HS Ductwork curve 13 SysLoop 11 6 AERAULIC ADJUSTEMENT 11 6 1 MODEL SL15 P1 Externa...

Page 16: ...ressure Pa LS MS HS HS MS LS Ductwork curve SL30 SL20 0 100 200 300 400 500 600 700 800 0 20 40 60 80 100 120 140 2V 3V 4V 5V 6V 7V 8V 9V 10V Air flow m3 h Available pressure Pa LS MS HS HS MS LS Ductwork curve SL30 SL20 0 100 200 300 400 500 600 700 800 0 20 40 60 80 100 120 140 2V 3V 4V 5V 6V 7V 8V 9V 10V Air flow m3 h Available pressure Pa LS MS HS HS MS LS Ductwork curve 14 SysLoop It is not n...

Page 17: ... not be held liable for damages caused when non treated or improperly treated water demineralized water salty water or sea water are used Apply the following guidelines No NH4 ammonium ions in the water highly detrimental to copper 10mg l Cl chloride ions are detrimental to copper with a risk of puncture by picking corrosion 10mg l SO4 2 sulphate ions may cause perforating corrosion 30mg l No fluo...

Page 18: ...aning and flushing out the hydraulic loop beforehand After performing these operations the units must be connected with all valves completely open ready for the system to be filled with water 3 Water exchanger clogging reduces efficient appliance operation We recommend the installation of a strainer filter Ø 0 8mm on the appliance s water inlet pipe The filter must be installed if the water circui...

Page 19: ...Each unit is supplied with a connector for condensates drainage 9 The condensates drainage line must comprise a siphon and run from the unit on a downward slope of at least 2 Generally the siphon is connected directly to the unit s condensates drainage outlet A length of plastic pipe can be used between the siphon and the condensates drainage line A complete condensates drainage system with copper...

Page 20: ...ntain the same pressure before and after the opening of the drain taps Flushing must be performed for at least two hours or longer if necessary until clear and clean water is obtained at the drain taps 3 Stop the additional heating and the water circulation pump Open all the bleed points and the drain taps to empty the system completely The short circuited water supplies and returns must now be co...

Page 21: ...fully qualified electrician and in accordance with local electrical standards and the wiring diagram corresponding to the unit model Any modification performed without our prior authorisation may result in the unit s warranty being declared null and void The power supply cable section must be sufficient to provide the appropriate voltage to the unit s power supply terminals both at start up and un...

Page 22: ...r s Plate for the voltages to be taken into consideration 2 Always shut down the power supply to the unit before connecting the thermostat wiring 15 2 REMOTE CONTROL 15 2 1 WALL MOUNTING 1 Separate the remote control from its rear plate Checking the support bracket Ensure that the wall surface is completely flat at the point where you wish to install the remote control as it is important that the ...

Page 23: ...B Lmax 700 M Master slaves operation requires the allocation of a specific address to each controller This addressing occurs by connecting a POL871 or POL895 display to the BSP BUS port of each controller Caution 21 SysLoop 15 2 2 ELECTRICAL CONNECTIONS SYSLOOP MODBUS The control return must be connected as per the following diagrams For the connection use a KNX TP1 type cable Twisted pair with in...

Page 24: ...itch the unit on or off Press and hold to activate scheduling To disable the time programming press briefly 2 Eco Comfort modes Briefly press to toggle from eco to comfort mode 3 Scheduling Time settings PROG Press and hold to set the unit s date and time When the minutes are set the unit displays the normal operating screen Briefly press to access time programming 4 Operating mode Briefly press t...

Page 25: ... the time on the room thermostat Icons Meanings SysLoop off AUTO Hourly programming active Operation in Eco mode Operation in Comfort mode COOL mode HEAT Mode Auto changeover mode The control displays the active heat or control mode Ventilation only C 23 5 When the unit is off the temperature displayed is that measured by the control s internal sensor When the unit is on the temperature displayed ...

Page 26: ...aved 24 SysLoop If the unit is in time programming mode the unit will switch to the mode shown in the current slot until the next slot begins Its state will then be the one of the future slot Once the time is confirmed the following slot is displayed Once the 6 slots confirmed the first slot of the day is displayed To disable a time slot replace the time with one day only 1 7 All the business days...

Page 27: ... to the ELECTRICAL POWER SUPPLY page 8 and in WIRING DIAGRAM page XI f 3 Before attempting any start up ensure that the air and water temperatures are within the appliance s operating limits in OPERATING LIMITS page 7 4 Rotate the fan by hand to ensure that it turns freely and that the fan turbine is properly attached to the motor shaft 5 Check that the condensates drainage pipe is properly attach...

Page 28: ...L mode and then set the minimum temperature with the UP and DOWN arrows The ambient temperature should be within the operating limits Refer to the OPERATING LIMITS page 7 In the same way during the pre commissioning checks the exchanger pump s water loop inlet temperature should be within the limits corresponding to each operating mode Refer to the OPERATING LIMITS page 7 Reminder if one of these ...

Page 29: ... replaced A more rigorous standard of cleanliness may be required 3 The condensates tray must be checked annually and cleaned and rinsed if necessary 4 Pressure checks are performed by means of the LP and HP pressures take offs on the fascia The gas contained in the pressure gauge hoses must be re injected as the gas charge is very low 5 On commissioning a record of voltages current draw and tempe...

Page 30: ...is insufficient Check for clogged filters Clean and replace as required 4 The cycle inversion valve may be defective and be creating a refrigerant by pass If the unit does not produce heat check the wiring of the inversion valve coil 5 Check the proper operation of the pressure relief valve 6 Measure the water flow on the water loop 7 Check the configuration of the appliance 19 1 4 INSUFFICIENT WA...

Page 31: ... unit serial number indicated on the name plate must be provided whenever service works or spare parts are ordered For any spare part order indicate the date of unit installation and date of failure Use the part number provided by our service spare parts if it not available provide full description of the part required 19 2 ALARM CODES Code Type Message 0 alarm HP pressure switch LP pressure switc...

Page 32: ...English 30 SysLoop ...

Page 33: ...APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO ...

Page 34: ...TION R1 AI RECT S4 AO 1Ø200 ODER R1 AI RECT S3 AO 1Ø200 VII KONFIGURATION R2 AI RECT S4 AO 1Ø200 ODER R2 AI RECT S3 AO 1Ø200 VIII KONFIGURATION R1 AI 1Ø200 S4 AO 1Ø200 ODER R1 AI 1Ø200 FAØ100 S4 AO 1Ø200 ODER R1 AI 1Ø200 FAØ125 S4 AO 1Ø200 ODER R1 AI 1Ø200 S3 AO 1Ø200 ODER R1 AI 1Ø200 FAØ100 S3 AO 1Ø200 ODER R1 AI 1Ø200 FAØ125 S3 AO 1Ø200 IX KONFIGURATION R2 AI 1Ø200 S4 AO 1Ø200 ODER R2 AI 1Ø200 F...

Page 35: ...45 457 45 18 917 5 953 547 5 583 54 89 130 31 4 65 212 12 432 24 227 12 83 356 249 Ø 1 2 Gas male S4 AO RECT R1 AI RECT III SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO DIMENSIONS DIMENSIONS ABMESSUNGEN DIMENSIONI DIMENSIONES CONFIGURATION R1 AI RECT S4 AO RECT ...

Page 36: ... 531 1030 18 45 827 45 18 18 45 457 45 18 917 5 953 547 5 583 54 227 12 83 356 130 31 4 65 212 12 432 24 249 89 Ø 1 2 Gas male S4 AO RECT R2 AI RECT IV SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R2 AI RECT S4 AO RECT ...

Page 37: ... 583 54 90 155 130 31 4 65 212 12 432 24 340 155 165 126 80 367 249 Ø 1 2 Gas male S4 AO RECT R1 AI 1Ø200 R1 AI 1Ø200 FAØ125 R1 AI 1Ø200 FAØ100 V SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R1 AI 1Ø200 S4 AO RECT OR R1 AI 1Ø200 FAØ100 S4 AO RECT OR R1 AI 1Ø200 FAØ125 S4 AO RECT ...

Page 38: ... 1031 165 126 54 181 367 130 31 4 65 212 12 432 24 90 155 249 Ø 1 2 Gas male S4 AO RECT R2 AI 1Ø200 R2 AI 1Ø200 FAØ100 R2 AI 1Ø200 FAØ125 VI SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R2 AI 1Ø200 S4 AO RECT OR R2 AI 1Ø200 FAØ100 S4 AO RECT OR R2 AI 1Ø200 FAØ125 S4 AO RECT ...

Page 39: ... 45 457 45 18 917 5 953 547 5 583 110 220 65 89 130 31 4 65 110 200 65 227 12 83 356 249 Ø 1 2 Gas male S4 AO 1Ø200 R1 AI RECT S3 AO 1Ø200 R1 AI RECT VII SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R1 AI RECT S4 AO 1Ø200 OR R1 AI RECT S3 AO 1Ø200 ...

Page 40: ...45 457 45 18 917 5 953 547 5 583 110 220 65 227 12 83 356 110 200 65 130 31 4 65 89 249 Ø 1 2 Gas male S4 AO 1Ø200 R2 AI RECT R2 AI RECT S3 AO 1Ø200 VIII SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R2 AI RECT S4 AO 1Ø200 OR R2 AI RECT S3 AO 1Ø200 ...

Page 41: ...le S4 AO 1Ø200 R1 AI 1Ø200 R1 AI 1Ø200 FAØ125 R1 AI 1Ø200 FAØ100 S3 AO 1Ø200 R1 AI 1Ø200 R1 AI 1Ø200 FAØ125 R1 AI 1Ø200 FAØ100 IX SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R1 AI 1Ø200 S4 AO 1Ø200 OR R1 AI 1Ø200 FAØ100 S4 AO 1Ø200 OR R1 AI 1Ø200 FAØ125 S4 AO 1Ø200 OR R1 AI 1Ø200 S3 AO 1Ø200 OR R1 AI 1Ø200 FAØ100 S3 AO 1Ø200 OR R1 AI 1Ø200 FAØ125 S3 AO 1Ø200 ...

Page 42: ...e S4 AO 1Ø200 R2 AI 1Ø200 R2 AI 1Ø200 FAØ100 R2 AI 1Ø200 FAØ125 S3 AO 1Ø200 R2 AI 1Ø200 R2 AI 1Ø200 FAØ100 R2 AI 1Ø200 FAØ125 X SysLoop APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO CONFIGURATION R2 AI 1Ø200 S4 AO 1Ø200 OR R2 AI 1Ø200 FAØ100 S4 AO 1Ø200 OR R2 AI 1Ø200 FAØ125 S4 AO 1Ø200 OR R2 AI 1Ø200 S3 AO 1Ø200 OR R2 AI 1Ø200 FAØ100 S3 AO 1Ø200 OR R2 AI 1Ø200 FAØ125 S3 AO 1Ø200 ...

Page 43: ...gelieferten Stromlaufplan hinzuziehen ATTENZIONE Questi schemi sono corretti al momento della pubblicazione Le varianti apportate nel corso della fabbricazione possono comportare modifiche Far sempre riferimento allo schema fornito con il prodotto ATENCIÓN Esto esquemas son correctos en el momento de la publicación Pero las variantes en la fabricación pueden ser motivo de modificaciones Remítase s...

Page 44: ...C1 Einphasenmodelle Condensatore del compressore C1 modelli monofase Condensador del compresor C1 modelos monofásicos RV1 4 way valve for cycle inversion Vanne 4 voies d inversion de cycle 4 Wege Umkehrventil für thermodynamisches Heizen Valvola 4 vie di inversione di ciclo Válvula de 4 vías de inversión de ciclo SW Detector of condensed water level Détecteur de niveau d eau de condensation Detekt...

Page 45: ...BATTERY OPTION OPTION BATTERIE ELECTRIQUE OPTION ELEKTRISCHE BATTERIE OPZIONE BATTERIA ELETTRICA OPCIÓN BATERÍA ELÉCTRICA KC1 Stage 1 heating relay Relais chauffage étage 1 Heizrelais Stufe 1 Relé riscaldanti stadio 1 Relé calefactores etapa 1 KC2 Stage 2 heating relay Relais chauffage étage 2 Heizrelais Stufe 2 Relé riscaldanti stadio 2 Relé calefactores etapa 2 EH1 Stage 1 heating elements Eléme...

Page 46: ...U 2 MP KC1 KC2 FA1 FA2 KC1 KC2 FM1 FM2 EH1 EH2 BU N1 N2 L L BU BU WH WH BK SS W SM1 2xRD 2xBK 2xBK RT ICT LWT SB2 5 6 7 FS N L NC C BK L2 L1 1 4 SB1 R1 3 BU BN L N 823 J581603 SYSLOOP 15 20 30 SE 4760 CW BU OG L L WH GY VT LP BU BU L C R S O 1 O 1 P Q64 DL1 SIEMENS 24 230V BSP BUS DN 115 230V C DO1 DO2 Q54 Q53 T HI T12 T6 T11 Q44 Q43 Q34 T9 Q33 T8 Q12 Q11 Q14 T7 24 230V 24 230V 24V 24V G0 B1 M B2 ...

Page 47: ...r cable section and wiring to the unit Ground cable is wired Main electrical protection suits the unit All electrical connections are correctly tightened YES NO Ground continuity on all pipes Water connection cleaning rinsing air bleed Anti frost protection of the water loop Mesh filter at the inlet of the unit Flowswitch cut out checked Condensate connection Presence of a regulating valve Presenc...

Page 48: ...ltage L N Nominal current L REMARKS DATE TECNICIAN Name Sign in DATE CLIENT Name Sign in COOLING MODE HEATING MODE Water loop system C C Water flow m3 h m3 h Water inlet temperature C C Water outlet temperature C C Air inlet temperature C C Air outlet temperature C C HP bar bar BP bar bar OPERATING READINGS YES NO Remote On Off dry contact ...

Page 49: ......

Page 50: ...M SL 01 S 1GB As part of our ongoing product improvement programme our products are subject to change without prior notice Non contractual photos Systemair AC SAS Route de Verneuil 27570 Tillières sur Avre FRANCE 33 0 2 32 60 61 00 6 33 0 2 32 32 55 13 ...

Reviews: