SystemAir SYSCONTROL RM 52 User Manual Download Page 4

5

5

6

6

Function buttons

1

2

 Each time the button is pressed, the operation 
 mode is selected in a sequence of  following:
   
  

3

MODE  Button    

 

4

5

ON/OFF Button

Operation starts when this button is pressed 
and stops when this button is pressed again.

NOTE:  

Heat mode is for Cooling & Heating  models only.

AUTO

COOL

DRY

HEAT

FAN 

SHORTCUT Button    

 

 TIMER ON Button    

 

 TIMER OFF Button    

 

Used to restore the current settings or resume previous settings.
On the first time connecting to the power, if push the SHORTCUT button, the unit 

O

will operate on AUTO mode, 26 C, and fan speed is Auto.
Push this button when remote controller is on, the system will automatically revert 
back to the previous settings including operating mode, setting temperature, fan 
speed level and sleep feature(if activated). And transmit the signals to the unit. 
If pushing more than 2 seconds, the system will automatically restore the current 
operation settings including operating mode, setting temperature, fan speed level 
and sleep feature(if activated ).

8

6

7

     SWING Button

 

     DIRECT Button

 

Used to change the louver movement and set the desired up/down air flow direction. 

O

The louver changes 6  in angle for each press. 
NOTE: On some models operate swing feature instead of this feature.

 

SELF CLEAN  Button    

 

UP Button(           )

 

o

Push this button to decrease the indoor temperature setting in 1 C increments 

o

to 17 C.

DOWN Button(            )

 

9

11

13

12

14

15

10

 

Used to select the fan speed in four steps: 

    AUTO     LOW     MED     HIGH

   
  

FAN Button    

 

Press this button to initiate the auto-on time sequence. Each press will increase 
the auto-timed setting in 30 minutes increments. When the setting time displays 
10.0, each press will increase the auto-timed setting 60 minutes increments. 
To cancel the auto-timed program, simply adjust the auto-on time to 0.0.

Press this button to initiate the auto-off time sequence. Each press will increase 
the auto-timed setting in 30 minutes increments. When the setting time displays 
10.0, each press will increase the auto-timed setting 60 minutes increments. 
To cancel the auto-timed program, simply adjust the auto-off time to 0.0

1

2

4
5

3

9

10

8

6

7

11

12

13
14

15

ON/OFF

MODE

FAN

TEMP

SHORT
   CUT

TIMER ON

TIMER OFF

SLEEP  FRESH

SWING  DIRECT

LED  FOLLOW ME

TURBO SELF CLEAN

Active/Disable Self Clean function

SLEEP Button    

 

FRESH Button    

 

NOTE: 

While the unit is running under SLEEP

mode, it would be cancelled if MODE, FAN 
SPEED or ON/OFF button is pressed.

Active/Disable sleep function. It can maintain 
the most comfortable temperature and save 
energy. This function is available on COOL, 
HEAT or AUTO mode only .

Active/Disable FRESH function. When the 
FRESH function is initiated, the Ionizer/Plasma 
Dust Collector(depending on models) is 
energized and will help to remove pollen and 
impurities from the air.

TURBO Button

Active/Disable Turbo function. Turbo function 
enables the unit to reach the preset temperature 
at cooling or heating operation in the shortest 
time(if the indoor unit does not support this 
function, there is no corresponding operation 
happened when pressing this button.)

LED Button

Disable/Active indoor screen Display. When 
pushing the button, the indoor screen display 
is cleared, press it again to light the display.
 

o

Push this button to increase the indoor temperature setting in 1 C increments 

o

to 30 C.

FOLLOW ME Button:

  Push this button to initiate the Follow Me feature, the 

remote display is actual temperature at its location. The remote control will send 
this signal to the air conditioner every 3 minutes interval until press the Follow Me 
button again. The air conditioner will cancel the Follow Me feature automatically 
if it does not  receive the signal during any 7 minutes interval. 

Used to stop or start horizontal louver auto swing feature.
NOTE; On some models used to stop or start vertical louver auto swing featrue. 

For the detail, see   sleep operation   in 
  USER S MANUAL.  

,

, ,

, ,

,,

,,

Summary of Contents for SYSCONTROL RM 52

Page 1: ...640 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Remote controller user manual SYSCONTROL RM 52 GB SYSPLIT Type ...

Page 2: ...acing the and ends correctly 3 Reattach the cover by sliding it back into position NOTE When the batteries are removed the remote controller erases all progra mming After inserting new batteries the remote controller must be reprogrammed Replacing batteries Handling the remote controller 2 2 Keep the remote controller where its signals can reach the receiver of the unit When you select the timer o...

Page 3: ...EF RG52B3 BG C E 5C 60C ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF MODE MODE MODE MODE MODE MODE FAN FAN FAN FAN SLEEP FAN FAN TEMP TEMP TEMP TEMP TEMP TEMP SHORT CUT SHORT CUT SHORT CUT SHORT CUT SHORT CUT SHORT CUT TIMER ON TIMER ON TIMER ON TIMER ON TIMER ON TIMER ON TIMER OFF TIMER OFF TIMER OFF TIMER OFF TIMER OFF TIMER OFF SLEEP SLEEP SLEEP FRESH SLEEP SLEEP FRESH SWING DIRECT SWING DIRECT SW...

Page 4: ...ce Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10 0 each press will increase the auto timed setting 60 minutes increments To cancel the auto timed program simply adjust the auto off time to 0 0 1 2 4 5 3 9 10 8 6 7 11 12 13 14 15 ON OFF MODE FAN TEMP SHORT CUT TIMER ON TIMER OFF SLEEP FRESH SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN Acti...

Page 5: ...E button to select COOL HEAT cooling heating models only or FAN mode 2 Press the UP DOWN buttons to set the desired temperature 3 Press the FAN button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner The temperature can O O O be set within a range of 17 C 30 C in 1 C increments In the FAN mode the setting temperature is not displayed...

Page 6: ...the auto on time of the unit Press the TIMER OFF button can set the auto off time of the unit 1 Press the TIMER ON button The remote controller shows TIMER ON the last Auto on setting time and the signal H will be shown on the LCD display area Now it is ready to reset the Auto on time to START the operation 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button...

Page 7: ...ater Auto off Operation The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed The air conditioner will stop automatically at the set time To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of stopping operation time and the signal H will show on the display area 2 Press the TIMER OFF button to display 10H on the TIME...

Page 8: ...urs after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button 4 Press the TIMER OFF button again to display 5 0H on the TIMER OFF display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated Off Stop Start 2 hours l...

Reviews: