![SystemAir PAW-200W5APAC Installation And Maintenance Manual Download Page 34](http://html.mh-extra.com/html/systemair/paw-200w5apac/paw-200w5apac_installation-and-maintenance-manual_1423363034.webp)
32
8.3 Physical data
WHE Units
8 - Technical Data
PAW-W5APAC
200
250
Power supply
V/ph/Hz
230V/1+N/50Hz
Number of refrigerant circuits
1
1
REFRIGERANT
Type
R32
CAPACITY
Nominal Cooling Capacity
kW
20
25
Nominal Heating Capacity
kW
23
28
EVAPORATOR
Type
Plate
Number
1
1
Water flow rate (cooling ΔT 5K)
m
3
/h
3,45
4,30
Water flow rate (heating ΔT 5K)
m
3
/h
4,15
4,85
Minimum flow rate
m
3
/h
2,00
2,50
Maximum flow rate
m
3
/h
6,80
8,00
Pressure drop
kPa
Refer to Hydraulic features
HYDRAULIC CONNECTIONS (EVAPORATOR)
Type
Threaded male
Inlet diameter
inch
1-1/4"
1-1/4"
Outlet diameter
inch
1-1/4"
1-1/4"
WEIGHT
Shipping weight
kg
35 (including flow switch kit and filter kit)
Operating weight
kg
27
DIMENSIONS
Length
mm
455
Width
mm
205
Height
mm
550
PAW
250
500
Rated voltage
V/ph/Hz
230V/1+N/50Hz
Max. absorbed power
kW
0,024
Max. current FLA
A
0,1
External fuses
A
1
Max. cable cross-section
mm
2
2,5
8.4 Electrical data