background image

152020

Warranty    |         5

2.1     

  Personnel

The fan may only be used by qualified, instructed and trained personnel. The persons must know the relevant safety directives in order 
to recognize and to avoid risks. The individual activities and qualifications can be found in Table 1 

Qualifications

, below.

Table 1 Qualifications

Activities

Electrical expert or

matching qualification

Fitter or matching

qualification

Trained personnel (see

following note)

Storage, operation, 

transport, cleaning, disposal

X

Electrical connection, commissioning, 

electrical disconnection 

X

Installation, disassembly

X

Maintenance

X

X

Repair

Smoke extraction fans and EX fans only by agreement with Systemair.

Note:

The operator is responsible for ensuring that personnel are instructed and have understood the contents of the operating 

instructions. If something is unclear, please contact Systemair or its representative.

i

2.2  

  Personal protective equipment

Wear protective equipment during all work in the vicinity of the fan.

 

 

•  protective working clothes 

•  protective working gloves 

•  goggles

 

•  protective working shoes 

•  helmet 

 

 

•  hearing protection

2.3  

  5 rules of electrical safety

•  Disconnect (disconnection of the electrical system from live components at all terminals)

•  Prevent reactivation

•  Test absence of voltage

•  Ground and short-circuit

•  Cover or restrict adjacent live parts

3  

  Warranty

The warranty for our products is determined by the contractual stipulations, our offers and our Terms and Conditions. Warranty claims 

presuppose that the product is properly connected, operated according to data sheets and serviced as needed. A correct commissioning

report must also be presented upon request. Please find the commissioning report attached to this document.

4  

  Delivery, transport, storage

4.1  

  Safety information

Warning: Risk from rotating fan blades

◊ Prevent access by unauthorized persons by safety personnel or access protection.

Warning: Suspended loads

◊ Wear protective equipment during all work in the vicinity of the fan, details see 2.2 

Personal protective equipment

, page 6.

◊ Do not walk under suspended loads.

◊ Make sure that there is nobody under a suspended load.

Summary of Contents for IV Smart AC

Page 1: ...Jet fan IV Smart AC IV Smart EC Installation and Operating Instructions EN...

Page 2: ...ht Systemair All rights reserved Systemair reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed...

Page 3: ...nditions 9 7 2 Installation on the ceiling 9 8 Electrical connection 10 8 1 Safety information Preconditions 10 8 2 Preconditions 10 8 3 Connection 10 8 3 1 Wiring diagram IV Smart AC 10 8 3 2 Wiring...

Page 4: ...d use Read the operating instructions completely and carefully Keep the operating instructions and other valid documents such as the circuit diagram or motor instructions with the fan They must always...

Page 5: ...in the vicinity of the fan protective working clothes protective working gloves goggles protective working shoes helmet hearing protection 2 3 5 rules of electrical safety Disconnect disconnection of...

Page 6: ...uit or malfunction Never transport the fan by the connecting wire terminal box rotor protection grille inlet cone or silencer In open transport please make sure that no water can penetrate into the mo...

Page 7: ...tors are suitable for 60Hz The input voltage for single phase units can vary between 208 and 230 V 5 3 Dimensions 5 4 Technical data of the fan IV Smart AC Temperature range F of transported air 13 to...

Page 8: ...an air density of 0 07 lb ft3 sea level and a maximum air humidity of 80 The fan is suitable for conveying clean air with a density of 0 08 lb ft3 and a max air humidity of 95 5 7 Incorrect use Incorr...

Page 9: ...nting options A If you are mounting to concrete you may mount directly with appropriate concrete fasteners B If you are mounting to steel or wood frames you must use vibration isolators Ensure that th...

Page 10: ...or deactivated Install a circuit breaker in the permanent electrical installation with a contact opening of at least 1 8 at each pole 8 3 Connection Check if the data on the nameplate matches the con...

Page 11: ...ar protective equipment during all work in the vicinity of the fan details see 2 2 Personal protective equipment page 5 9 2 Preconditions Installation and electrical connection have been correctly per...

Page 12: ...irection of rotation conveyance The direction of rotation always applies looking at the rotor The direction of rotation is best observed just before the fan stops Smooth running any vibrations and noi...

Page 13: ...rature Ensure that the temperature does not exceed the certified value Install new rotor Vibrations oscillations Check the installation of the fan Air output of fan too low Rotor rotates in wrong dire...

Page 14: ...sure that the intake of the fan is free from dirt X Check that fan and components are being used as intended X Check the current consumption X Check that the vibration dampers function correctly if us...

Page 15: ...weights that have been positioned Keep the airways of the fan clear and clean them if necessary with a brush 13 Deinstallation dismantling Deinstall and dismantle the fan in reverse order of installat...

Page 16: ...ins 0 10 V signal EC motor via contractor control Transformer Frequency converter Sinus filter Shielded cables Motor protection Motor protection switch or motor protection relay PTC resistor Resistanc...

Page 17: ...1 A Pressure between suction side and discharge of the fan If an airflow measurement is not possible this value can be calculated using the following formula Duct cross section sq ft Flow speed ft min...

Page 18: ...Ventilador de impulso IV Smart CA IV Smart EC Instrucciones de instalaci n y funcionamiento ES...

Page 19: ...ir Todos los derechos reservados Systemair se reserva el derecho de modificar sus productos sin previo aviso Esto tambi n se aplica a los productos ya pedidos siempre que no afecte las especificacione...

Page 20: ...n el techo 26 8 Conexi n el ctrica 27 8 1 Informaci n de seguridad Condiciones previas 27 8 2 Condiciones previas 27 8 3 Conexi n 27 8 3 1 Diagrama de cableado AC para IV Smart 27 8 3 2 Diagrama de ca...

Page 21: ...rma completa y con atenci n Mantenga las instrucciones de funcionamiento y otros documentos v lidos como el diagrama de circuitos o las instrucciones del motor junto al ventilador Deben estar siempre...

Page 22: ...gafas de seguridad calzado de trabajo protector casco protecci n auditiva 2 3 5 reglas de seguridad el ctrica Desconectar desconexi n del sistema el ctrico de los componentes activos en todos los ter...

Page 23: ...funcionamiento Nunca transporte el ventilador mediante el cable de conexi n la caja de terminales el rotor la parrilla protectora el cono de entrada o el silenciador Durante el transporte abierto aseg...

Page 24: ...on compatibles con 60 Hz El voltaje de entrada para las unidades monof sicas puede variar entre 208 y 230 V 5 3 Dimensiones 5 4 Datos t cnicos del ventilador IV Smart AC Rango de temperatura F del air...

Page 25: ...ican a una densidad del aire de 0 07 lb pie3 nivel del mar y una humedad del aire m xima del 80 El ventilador es ideal para suministrar aire limpio con una densidad de 0 08 lb pie3 y una humedad del a...

Page 26: ...de objetos extra os 7 1 Condiciones previas Montaje A Si est montando en concreto puede montar directamente con sujetadores de concreto apropiados B Si est montando en marcos de madera o acero debe u...

Page 27: ...e seguridad Instale un disyuntor en la instalaci n el ctrica permanente con una apertura de contacto de al menos 1 8 en cada polo 8 3 Conexi n Compruebe que los datos de la placa de identificaci n coi...

Page 28: ...l trabajo en las cercan as del ventilador consulte los detalles en 2 2 Equipo de protecci n personal en la p gina 22 9 2 Condiciones previas La instalaci n y la conexi n el ctrica se realizaron correc...

Page 29: ...rte La direcci n de rotaci n siempre se aplica de frente al rotor La direcci n de rotaci n puede observarse de mejor manera antes que se detenga el ventilador Funcionamiento suave sin vibraciones ni r...

Page 30: ...e de que la temperatura no exceda el valor certificado Instale un rotor nuevo Vibraciones oscilaciones Compruebe la instalaci n del ventilador Salida de aire o ventilador demasiado bajo El rotor gira...

Page 31: ...Verifique que el ventilador y los componentes se utilicen en forma adecuada X Verifique el consumo de corriente X Verifique que los amortiguadores de vibraci n funcionen correctamente si se utilizan X...

Page 32: ...Mantenga las ventilaciones de aire del ventilador limpias y de ser necesario l mpielas con un cepillo 13 Desintalaci n desmantelamiento Desinstale y desmantele el ventilador en el orden inverso de la...

Page 33: ...y to mains 0 10 V signal EC motor via contractor control Transformer Frequency converter Sinus filter Shielded cables Motor protection Motor protection switch or motor protection relay PTC resistor Re...

Page 34: ...A Pressure between suction side and discharge of the fan If an airflow measurement is not possible this value can be calculated using the following formula Duct cross section sq ft Flow speed ft min A...

Page 35: ...152020 Notas 35...

Page 36: ...Systemair All rights reserved Systemair reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed spe...

Reviews: