7
MOUNTING OPTIONS
LOCATION
• Must be located in a conditioned space
where it will be possible to conveniently
service the unit.
• Typically located close to the outside wall
where the hoods will be mounted.
• A utility room when basement is not
possible.
Attic installation must meet the following
conditions:
• Attic temperature must be above
freezing conditions at all times and
for best performance should be
12°C (54 °F).
• The attic is easily accessible for
equipment maintenance and inspection.
WALL MOUTING BRACKET INSTALLATION
CHAIN MOUNT INSTALLATION - OPTIONAL
* Hanging kit not included.
When wall mount bracket is not
convenient. Use a chain kit (which includes
hanging chains, 10-24 screws, spring, and
hooks)
Install a spring on each chain as shown
to support the unit's weight and absorb
vibrations.
Safety screws
(included)
16” (406
mm)
DO NOT
Connecting appliances to the HRV is not
recommended. These include:
• Clothes dryer
• Range top
• Stovetop fan
• Central vacuum system
• Bathroom exhaust fans unless they are
specifically designed for this purpose
• These appliances may cause lint, dust or
grease to collect in the HRV, damaging
the unit.
Connecting any of these
types of appliances to
the HRV will void your
warranty.
Summary of Contents for Fantech HERO 200H
Page 10: ...10 WIRING DIAGRAM HERO 120H 150H 200H LOW SPEEDS 90V 75V J4 J5 J6 ...
Page 11: ...11 WIRING DIAGRAM HERO 150H EC 250H EC CONT D ...
Page 16: ...16 NOTES ...
Page 26: ...26 SCHÉMA DE CÂBLAGE HERO 120H 150H 200H LOW SPEEDS 90V 75V J4 J5 J6 ...
Page 27: ...27 SCHÉMA DE CÂBLAGE HERO 150H EC 250H EC SUITE Model ON ON ON ON ON ONON ON ON ...