INSTALLATION TYPES
Example only – duct configuration may differ depending on the model.
1. Stale air is drawn from areas requiring
local exhaust (bathroom, kitchen, laundry
room).
2. Fresh air is distributed to habitable rooms
(bedrooms, living room)
3. The HRV’s airflow must be balanced after
installation using the procedure found in
the section “AIRFLOW BALANCING.”
Suggested for:
• Hydronic baseboard
• In floor heating
• Electric baseboard
• Mini split heat pump
Benefits:
Provides the best fresh air distribution in
the house; lowest operation cost since the
furnace/air handler unit is not needed.
1. The furnace blower is set to run
continuously or interconnected with HRV
for proper fresh air distribution. See
furnace electrical connection on page 12.
2. Stale air is drawn from areas requiring
local exhaust (bathroom, kitchen, laundry
room).
3. Fresh air is supplied to the return air
plenum of the furnace.
4. Due to the difference in pressure, HRV's
airflow must be balanced on site using the
procedure found in the section “AIRFLOW
BALANCING.”
* In the case of a multi-zone system, please
contact Fantech customer service prior to
installing any installation type requiring the use
of the furnace interlock
Suggested for:
• Central furnace
• When ducting fresh air to living area is
not possible or practical
Benefits:
Conditions the fresh air prior to distributing
it throughout the house
1. The furnace blower is set to run
continuously or interconnected with HRV
for proper fresh air distribution. See
furnace electrical connection on page 12.
2. A minimum separation of 1 m (39’’) is
recommended between the two direct
connections.
3. The HRV’s exhaust air connection should be
upstream of the HRV’s supply air
connection to prevent exhausting any fresh
air.
4. Due to the difference in pressure, HRV's
airflow must be balanced on site using the
procedure found in the section “AIRFLOW
BALANCING.”
* In the case of a multi-zone system, please
contact Fantech customer service prior to
installing any installation type requiring the use
of the furnace interlock"
Suggested for:
• Whe
n bathroom and kitchen already have
local exhaust system
• May be suita
ble for retrofitting
Benefits:
Least expensive installation type
HRV DUCTING FOR FULLY
DEDICATED SYSTEM
HRV/FURNACE DUCTING FOR
PARTIALLY DEDICATED SYSTEM
HRV/FURNACE FOR
SIMPLIFIED INSTALLATION
BEST
BETTER
GOOD
Make sure the HRV is
capable of meeting the
required airflow rate.
Summary of Contents for Fantech HERO 200H
Page 10: ...10 WIRING DIAGRAM HERO 120H 150H 200H LOW SPEEDS 90V 75V J4 J5 J6 ...
Page 11: ...11 WIRING DIAGRAM HERO 150H EC 250H EC CONT D ...
Page 16: ...16 NOTES ...
Page 26: ...26 SCHÉMA DE CÂBLAGE HERO 120H 150H 200H LOW SPEEDS 90V 75V J4 J5 J6 ...
Page 27: ...27 SCHÉMA DE CÂBLAGE HERO 150H EC 250H EC SUITE Model ON ON ON ON ON ONON ON ON ...