a)  Hold the mounting bracket against the surface it is to be mounted.
b)  Mark the location of the two most useful key slots and remove the bracket. Using the provided ¾” long wood screws, attach screws 
into the structure leaving 1/8” space between the screw head and mounting surface.
c)  Using the provided self-tapping screws, attach the bracket to the fan as shown.
 

Figure. B

d)  Holding the new assembled fan and bracket, align the key slots with the mounting screws and lock them into place.

Duct Installation (STEP 4)

Leave adjoining dryer duct a minimum of 10-1/8” away from fan inlet and outlet.  Install the 10” long cleanout duct using the FC4 duct 
clamps.  See dimensional data below. 

Pressure Switch Connection (STEP 5)

Do not connect the tubing in such a manner as to allow condensation from the duct to collect in the tubing

Drill a 3/8 inch diameter hole in the duct wall 6 to 8-inches from the inlet of the fan. Carefully insert the grommet into the hole.

Drilling into a metal duct may produce sharp burrs. Needle nose pliers can be used to remove or flatten sharp edges.

a)  Attach one end of the clear pressure tubing to  
  the pressure sensor located on the electrical   
 box.
b)  Mark the opposite end of the pressure tubing ½  
  inch from the edge and insert into the grommet  
  until the marking is reached.

Indicator Panel (STEP 6)

The DEDPV-705 is equipped with a remote mount, low voltage, operation indicator panel.  This wall-mounted indicator panel contains a 
blue LED that is intended to visually alert the occupant of any detected faults.  The panel must be mounted in a 2 gang decora switch 
plate with a warning label (decora plate and label provided).  Refer to page 3, paragraph C for the required mounting location.

Connecting Indicator Panel (STEP 7)

Connect the end of the 50-foot cable that has a mating two-position connector to the receptacle located on the dryer booster fan control 
box.

Summary of Contents for Fantech DEDPV-705

Page 1: ...ng 2 pcs FC4 Clamps 4 pcs Grommet for Tubing 1 pc Mounting Bracket and Hardware 1 pc Indicator Panel 1 pc 4 x 4 Indicator Cover Plate 1 pc 50 ft 15 4 m Communication Cable 1 pc Warning Label for Indicator Cover Plate 1 pc registration fantech app REGISTER THIS PRODUCT TO INCREASE YOUR PRODUCT WARRANTY BY AN EXTRA YEAR in USA only IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPOTANTES POUR LA SÉCURI...

Page 2: ...INTENANCE 7 TROUBLESHOOTING 8 No Indicator Light 8 Single Flash 8 Double Flash 8 Triple Flash 8 WARRANTY 9 A Dryer Exhaust Duct Power Ventilator DEDPV is a term used for an appliance specifically designed to assist a single residential dryer gas or electric in overcoming dryer performance loss caused by long or restrictive duct configurations Dryer Exhaust Duct Ventilator differs from the term dry...

Page 3: ...to open any doors other than those necessary to access the dryer AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE DE CHOC ÉLECTRIQUE OU DE BLESSURE RESPECTER LES CONSIGNES QUI SUIVENT a Votre sécheuse est équipée d un ventilateur auxiliaire qui peut être installé loin de la sécheuse comme dans un grenier un vide sanitaire ou un sous sol b Le ventilateur auxiliaire est essential au fonctionnement sé...

Page 4: ...rities having jurisdiction ATTENTION NE PAS INSTALLER DANS LE CONDUIT D EVACUATION DE LA SECHEUSE SI LES INSTRUCTIONS INTERDISENT L INSTALLATION D UN VENTILATEUR AUXILIAIRE NE PAS INSTALLER DANS UN CONDUIT D EVACUATION MESURANT 7 62 MÉTRES 25 PI DE LONGUEUR OU MOINS Le DEDPV 705 est adapté pour surmonter une longueur équivalente de conduit de 125 pieds 38 mètres de conduit en acier galvanisé de 4 ...

Page 5: ...EXHAUST DUCT FITTING TYPE EQUIVALENT LENGTH 45 degree elbow 2 1 2 feet 90 degree elbow 5 feet Source IRC 2018 Table M1502 4 5 1 Elevation Max Eq Duct Length ft Sea Level 125 2000 114 4000 106 6000 98 8000 92 10 000 85 Fan Mounting Location STEP 2 The DEDPV 705 can be mounted a minimum of 5 linear feet maximum linear 40 ft down stream of the dryer outlet connection If the DEDPV is installed less th...

Page 6: ...iameter hole in the duct wall 6 to 8 inches from the inlet of the fan Carefully insert the grommet into the hole Drilling into a metal duct may produce sharp burrs Needle nose pliers can be used to remove or flatten sharp edges a Attach one end of the clear pressure tubing to the pressure sensor located on the electrical box b Mark the opposite end of the pressure tubing inch from the edge and ins...

Page 7: ...If after a complete 5 minute run cycle the DEDPV does not sense pressure from the dryer the DEDPV 705 will engage in a final 5 minute cool down cycle before turning OFF Since fan bearings are sealed and provided with an internal lubricating material no additional lubrication is necessary Fan impeller may accumulate lint Periodic inspection based upon dryer usage should be performed to ensure that ...

Page 8: ...tenance on all dryer exhaust systems are necessary to ensure lint is not accumulating and creating blockages A hall effect sensor integral to the motor is used to sense the rotation of the fan wheel A loose connection within the fan electrical box can cause the system to think there is no rotation Solution Call Technical Support for authorization to open the electrical box and check connection H1 ...

Page 9: ...n for any breach of warranty WARRANTY INVALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an applicable consumer protection legislation You may have additional rights which vary from state to state LIMITATION OF WARRANTY AND LIABILITY This warranty does not apply to any Fantech product or part which h...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...

Reviews: