background image

2

Operation

Warning

• This product is not intended to be used by children or people with reduced physical or mental ability or

lack of experience and knowledge, if no instruction concerning the use has been given by the person
responsible for their safety or that this person is supervising the operation. Children should be supervised
so that they can not play with the product.

• Beware of sharp edges during mounting and maintenance. Use protective gloves.

Warning

• Although the mains supply to the unit has been disconnected there is still a risk of injury due to rotating

parts that have not come to a complete standstill.

3

Operation

The unit can be controlled by one or more control methods:

• SAVE LIGHT control panel, refer to 2.

• SAVE TOUCH control panel, refer to 3.

• SAVE CONNECT, refer to 3.

3.1

SAVE LIGHT control panel

Fig. 2 Explanation of symbols

SAVE LIGHT is a basic control panel for SAVE series resi-
dential air handling units. SAVE LIGHT allows to change
airflow levels and indicates when any alarm is present.

1. A button to increase airflow

2. A button to reduce airflow

3. Current airflow level/mode

4. Filter change LED

5. General alarm LED

3.1.1

Indicators

General alarm LED shows when any alarm has occurred. Alarm type is not specified.
It is not possible to acknowledge alarms from the SAVE LIGHT control panel. Please check SAVE TOUCH
control panel or contact your local technical service provider.

The filter change LED shows when filters have to be replaced.
Filters cannot be cleaned and must be changed as necessary. This is normally done 2–3 times per year
depending on the air pollution at the installation site.

3.1.2

To select airflow level

LEDs show current airflow level (figure 2, pos. 3).

• Press

button to increase the airflow.

• Press

button to decrease the airflow.

254538 | v1

Summary of Contents for 488819

Page 1: ...Document in original language 254538 v1 SAVE VTR 150 B User Manual GB...

Page 2: ...stemair UAB All rights reserved E OE Systemair UAB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...nge the temperature 7 3 2 7 To change the airflow 7 3 2 8 To set a week schedule 8 4 Maintenance of the unit 9 4 1 Maintenance Schedule 9 4 2 To access internal components 9 4 3 To change filters 10 4...

Page 4: ......

Page 5: ...t Systemair will require these in the case of a warranty claim 1 3 Type label Before calling your service representative make a note of the specification and production number from the type label whic...

Page 6: ...SAVE LIGHT control panel Fig 2 Explanation of symbols SAVE LIGHT is a basic control panel for SAVE series resi dential air handling units SAVE LIGHT allows to change airflow levels and indicates when...

Page 7: ...ensation when the unit has been stopped 3 1 3 To cancel sleep mode Press any button to cancel the sleep mode SAVE LIGHT returns to the sleep mode after 3 minutes of inactivity All control panel lights...

Page 8: ...ge number and the second number indicates a total number of pages available Many options show up in a form of the pop up window Select the option from the displayed list in the pop up window and press...

Page 9: ...uick information screen shows the following information 1 Time 2 Outdoor temperature 3 Current User mode Alarm 4 Fan speed off Minimum Low Normal High Maximum 5 Supply air temperature 6 Relative humid...

Page 10: ...irflow setting in Week Schedule Manual Manual selection of airflow levels The unit can be set run at one out of four available airflow speeds Off Low Normal High Note The fan can be set to OFF by acti...

Page 11: ...ettings of all modes can be modified in Service menu 3 2 6 To change the temperature Touch the thermometer symbol on the home screen to open the temperature settings window Use up and down arrows to i...

Page 12: ...Use arrow buttons and to increase or decrease value Confirm with OK button Note Scheduled time can start but never end at midnight 00 00 The latest END TIME period is 23 59 Scheduled time cannot go t...

Page 13: ...ied out correctly and written evidence thereof is provided 4 1 Maintenance Schedule Task 6 months 1 year 3 years When necessary General inspection X Filter change X X Fan cleaning X Heat exchanger cle...

Page 14: ...set the filter change time Once filter is changed it is necessary to reset filter time Go to Filter menu see 3 2 2 Home screen overview page 4 pos E or if filter alarm is present click on alarm status...

Page 15: ...not exposed to moisture 4 Remount the rotor Don t forget to reconnect the rotor power and sensor cables 4 5 To clean fans Danger Make sure that the Mains supply to the unit is disconnected before perf...

Page 16: ...ve the side cover 3 Remove the broken drive belt 4 Use tape to attach the drive belt to the rotating heat exchanger and rotate the exchanger by hand to get hold of the drive belt 5 Remove the tape and...

Page 17: ...of the installation The duct runs should therefore be cleaned changed when necessary Steel ducts can be cleaned by pulling a brush soaked in hot soapy water through the duct via diffuser louvre openi...

Page 18: ...panel or via a hardwired switch 6 Check the analogue inputs in the service menu to verify that the temperature sensors are functioning correctly 7 In case of installed electrical other re heater batte...

Page 19: ...254538 v1...

Page 20: ...SAVE VTR 150 B User Manual 254538 en_GB 2021 03 15 v1 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Reviews: