background image

D900-03-00

1

I56-380-04

V400R (Red), V400B (Beige) Speakers for

Fire Protective Signaling Systems and

Strobes SS12LO, SS24LO, SS24LOC,

SS24M, and SS24MC for these Speakers

INSTALLATION AND MAINTENANCE INSTRUCTIONS

A Division of Pittway

 3825 Ohio Avenue, St. Charles, Illinois 60174

1-800-SENSOR2, FAX: 630-377-6495

General Description

The National Fire Protection Association has published
standards and recommended practices for the installation
and use of the appliances described in these instructions.
System Sensor recommends that the installer become fa-
miliar with these standards and practices, local codes, and
any special requirements of the authority having jurisdic-
tion.

The speaker can operate at any one of four input power lev-
els (1/4, 1/2, 1, or 2 watts)  at either of two input voltages
(25V

rms

 or 70.7V

rms

 ). The rms voltage and power levels are

selected at the time of installation, but can be changed, if
necessary.

The speaker is equipped with a capacitive input to allow
for DC supervision.

Optional strobes are available for use with the speaker. Al-
though they are assembled into a unit at the time of instal-
lation, the strobe and speaker are electrically independent
and require separate power sources. Strobes must be pow-
ered by means of an uncoded full-wave rectified, filtered or
unfiltered supply. Model SS12LO is for use with 12 volt
panels and Models SS24LO and SS24M are for 24 volt pan-
els. The strobe CANNOT be supervised when it is attached
to the speaker and is considered a supplementary signaling
device.

Specifications

Voltage Input:

25 V

rms

 or 70.7 V

rms

Input Power Taps:

1/4 Watt, 1/2 Watt, 1 Watt, or 2 Watts

Frequency Range:

400 to 4000 Hz

Supervision:

Capacitive input for supervisory DC voltage

Grille Size:

4"  X 4"

Cone Material:

Weather resistant

Mounting:

Standard 4" X 4" electrical box
Surface mount directly to box
Semiflush mount, using model MP-SF or MP-SFB  (red or beige)
Flush mount, using Model MP-F or MP-FB.
Ceiling mount, using flush mount kit MP-F or  MP-FB. Use Models SS24LOC and
SS24MC Strobes (optional) for ceiling-mounted installations.

Input Terminals:

14 to 18 AWG

Operating Temperature Range:

32

°

 to 120

°

F

Installation

Electrical

Install the electrical wiring in compliance with all appli-
cable local codes as well as any special requirements of the
authority having jurisdiction, using the proper wire size.
1. Connect the speaker and strobe as shown in Figure 1.

Keep in mind that if an optional strobe has been at-
tached to the speaker, the speaker and strobe are electri-
cally independent. The speaker must be connected to a
25V

rms

 or 70.7 V

rms

 amplifier and the strobe to an

uncoded DC power supply.

Even though V400 series speakers can be used with 25
V

rms

 or 70.7 V

rms

 amplifiers, permanent damage can result

if the speaker is improperly connected. Therefore, be
sure to use the COM and 25 terminals when a 25 V

rms

amplifier is being used. Similarly, use the COM and 70
terminals if a 70.7 V

rms

 amplifier is in the system.

NOTE

: Do NOT loop electrical wiring under terminal

screws. Wires connecting the device to the control
panel must be broken at the device terminal con-
nection to ensure electrical supervision.

2. See Figure 1. The speaker is equipped with five posts

and an associated plug with red and black wires. The
center post is labeled COM (common) while the others
are labeled 2W, 1/4W, 1/2W, and 1W, respectively.

These posts enable the installer to select any one of four
power levels by installing the plug onto COM and the ap-

Technical Manuals Online! - http://www.tech-man.com

Summary of Contents for P1R24110ADA

Page 1: ...unfiltered supply Figure 1 Electrical connections Specifications Mechanical Input Terminals 12 to 18 AWG 3 31 to 0 82 mm2 Speaker Size 4 inches 101 mm Grille Size Round 7 3 8 187 mm Square 5 127 mm Electrical Voltage Input 25 volts or 70 7 volts nominal Frequency Range 400 4000 Hz Operating Temperature Range 32 to 120 F 0 to 49 C Installation All wiring must be installed in compliance with the Na ...

Page 2: ...ltage input power level combina tion being used NEVER connect the yellow jumper to the posts numbered 1 through 6 or the blue jumper to lettered posts A or B Mechanical Slotted head screws are included for attaching the speaker to the electrical junction box Insert the decorative filler plugs supplied into the remaining two holes in the grille Mounting See Figure 2 The speaker can be flush mounted...

Page 3: ...10 24M speaker w strobe speaker w strobe 24 24 25 mA 25 mA 45 mA rms 125 mA rms 1 5 cd 15 cd Strobe Light Ratings The signaling strobe is rated for 0 to 49 C and is not suit able for outdoor use See Figure 3 The light output of the SP10 24LO is 1 5 cd minimum when it is viewed from the front The light out put of the SP10 24M is 15 cd minimum when it is viewed from the front Under no circumstances ...

Page 4: ...s including this strobe are activated System Sensor recommends that the speaker and signal strobe always be used in combination so that the risks from any of the above limitations are minimized WARNING The Limitations of Speaker Strobes Three Year Limited Warranty System Sensor warrants its enclosed speaker strobe to be free from defects in materials and workmanship under normal use and service fo...

Page 5: ...ied unfiltered supply Installation For Strobe Replacement See NFPA 72 Chapter 6 All wiring must be installed in compliance with the Na tional Electrical Code and all applicable local codes as well as any special requirements of the authority having juris diction using the proper wire size This also includes all applicable NFPA Standards ANSI UL 1480 and NEC 760 Figure 1 Electrical connections Spec...

Page 6: ...ltage input power level combina tion being used NEVER connect the yellow jumper to the posts numbered 1 through 6 or the blue jumper to lettered posts A or B Mechanical Slotted head screws are included for attaching the speaker to the electrical junction box Insert the decorative filler plugs supplied into the remaining two holes in the grille Mounting See Figure 2 The speaker can be flush mounted...

Page 7: ...0 1 0 Note Inrush current lasts on the order of microseconds Table 3 SP100W24MC LO 1 5 cd UL 1638 Strobe M 15 cd UL 1638 Strobe 24 24 VDC Strobe SP100W Round Grille White Speaker SP101W Square Grille White Speaker SP101R Square Grille Red Speaker C Ceiling mount SP1R2415ADA 15 15 cd UL 1971 Strobe 1575 15 cd UL 1971 Strobe 75 75 cd UL 1971 Strobe 110 110 cd UL 1971 Strobe 24 24 VDC Strobe SP1R Squ...

Page 8: ...d System Sensor recommends that the speaker and signal strobe always be used in combination so that the risks from any of the above limitations are minimized WARNING The Limitations of Speaker Strobes Three Year Limited Warranty System Sensor warrants its enclosed speaker strobe to be free from defects in materials and workmanship under normal use and service for a period of three years from date ...

Page 9: ...0 Hz Supervision Capacitive input for supervisory DC voltage Grille Size 4 X 4 Cone Material Weather resistant Mounting Standard 4 X 4 electrical box Surface mount directly to box Semiflush mount using model MP SF or MP SFB red or beige Flush mount using Model MP F or MP FB Ceiling mount using flush mount kit MP F or MP FB Use Models SS24LOC and SS24MC Strobes optional for ceiling mounted installa...

Page 10: ...unting the speaker on the electrical box The other two holes will be used to attach the strobe and flush mount plate to the speaker c Position the strobe over the speaker and guide its two power lugs into the slots formed when the flash was removed in step 2 a Attach the strobe and flush mount plate to the speaker using 8 phillips head sheet metal screws through the pair of strobe mounting holes t...

Page 11: ...in the electrical box using two 8 32 X 2 3 4 screws 2 Speaker with Strobe Figure 7 a Use a small bladed screwdriver to remove the plastic flash from the two strobe blade slots on the speaker and flush mount plate b See Figure 3 Identify the two diagonally opposite speaker holes that will be needed for mounting the speaker on the electrical box The other two holes will be used to attach the strobe ...

Page 12: ...ng any of the methods described in this manual There fore follow the appropriate procedure to mount the speaker strobe on a ceiling 8 32x1 7 16 8 32x 1 7 16 8 S M 8 S M 6 32x5 8 6 32x5 8 8 NUTS V400 MP SF Plaster Ring Standard Backbox 8 32x5 8 A78 1799 02 Figure 8 Plaster Ring Mount 8 32x1 8 32x2 3 4 8 32x2 3 4 8 32x1 MP F V400 8 NUT 8 NUT BB D Signal Strobe Figure 7 Speaker Strobe Flush Mount A78...

Page 13: ...ing model MP SF or MP SFB Model Supply Voltage Range Operating Current from Regulated Supply Operating Current from Full Wave Rectified Unfiltered Supply Average Operating Current Average Operating Current mArms Peak Current mA 20Vrms 30Vrms Peak Current mA 20 30V Inrush Current mA in access of Peak Inrush Current Amps in excess of Peak V4R24110ADA V4R2475ADA V4R2415ADA V4R241575ADA 20 30V 210 470...

Page 14: ...vice to the control panel must be broken at the device terminal con nection to ensure electrical supervision Figure 1 Vertical and horizontal light distribution Degrees of Rating 0 100 5 25 90 30 45 75 50 55 55 45 60 40 65 35 70 35 75 30 80 30 85 25 90 25 LIGHT 0 45 45 90 90 2 See Figure 2 The speaker is equipped with five posts and an associated plug with red and black wires The center post is CO...

Page 15: ...holes in the speaker strobe D Plaster Ring Mount See Figure 5 Follow the Semiflush Wall Mount proce dure except attach the semiflush plate to the electrical box using the two 6 32 X 5 8 screws 6 32x5 8 V400 8 32x1 7 16 8 Sht Mtl Signal Strobe 8 32x1 7 16 8 Sht Mtl 6 32x5 8 8 32x5 8 Figure 5 Plaster ring mount A78 1799 01 8 32x1 7 16 8 Sht Mtl 8 Sht Mtl 8 32x1 7 16 Signal Strobe V400 Figure 3 Surfa...

Page 16: ...robe must have an un interrupted source of DC power in order to operate correctly System Sensor recommends that the speaker and signal strobe always be used in combination so that the risks from any of the above limitations are minimized WARNING The Limitations of Speakers and Speaker Strobes Three Year Limited Warranty System Sensor warrants its enclosed speaker strobe to be free from defects in ...

Reviews: