FIGURE 4:  WIRING DIAGRAM  

(CONNECTED TO 24V POWER USING COMPATIBLE FACP WITH “SOUNDER BASE STANDBY POWER MONITORING” ENABLED)

FIGURE 5: WIRING DIAGRAM (CONNECTED TO NAC OR 24V POWER; OPTIONAL EOL DEVICES FOR CONSTANT SUPERVISION)

(+) SLC

(–) SLC

(–) CONSTANT POWER

(–) NAC

(+) CONSTANT POWER

(+) NAC

U.L. LISTED COM

PA

TIBLE

CONTRO

PA

NE

L

OPTIONAL REMOTE

ANNUNCIATOR MODEL

RA400Z/100Z

CLASS A OPTIONAL WIRING

FIRST

SOUNDER

BASE

SECOND

SOUNDER

BASE

NTH

SOUNDER

BASE

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

R

(+)

(+)

(+)

(–)

(–)

(–)

E

O

L

A SEPERATE SYNCHRONIZATION MODULE MAY BE USED TO PROVIDE
THE SYNCHRONIZATION PULSES  (SEE FIGURE 6)

/

/

HORN

HORN

HORN/STROBE

(+) SLC

(–) SLC

(–) NAC OR CONSTANT POWER*

(+) NAC OR CONSTANT POWER*

(+) NAC

(–) NAC

OPTIONAL REMOTE

ANNUNCIATOR MODEL

RA400Z/100Z

CLASS A OPTIONAL WIRING

FIRST

SOUNDER

BASE

SECOND

SOUNDER

BASE

NTH

SOUNDER

BASE

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

NO
T

USED

SL

+

EXT 

EXT 
+

RA

SL

T PO

(+)

(+)

(+)

(–)

(–)

(–)

E

O

L

A SEPERATE SYNCHRONIZATION MODULE MAY BE 
USED TO PROVIDE THE SYNCHRONIZATION PULSES

/

/

E

O

L

/

/

HORN

HORN

HORN/STROBE

U.L. LISTED COM

PA

TIBLE

CONTRO

PA

NE

L

UL

 LISTED 24V

 

POWER  SUPPL

*WHEN USING 24V CONSTANT POWER 
(AUX POWER), ADDITIONAL POWER 
SUPERVISION RELAYS AND MODULES WILL
BE REQUIRED FOR PROVIDING SUPERVISION 
WHEN THE SOUNDER BASES ARE INACTIVE.

C0474-12

C0474-11

NOTE: Only use this wiring diagram when connecting to 24VDC power using a FACP listed in the table on page 1. Please consult your FACP manufacturer for 
panel-specific wiring configurations and special cases.

Additional Audible Visible devices may be connected to the same power supply or the the NAC output of the Fire Alarm Control Panel (FACP) to provide a syn-
chronized communication of the alarm signal.

(SEE FIGURE 6)

NOTE: Only use this wiring diagram when connecting to a NAC or a 24V power supply that does not support “sounder base standby power monitoring”  
(see page 1). 

  

I56-4151-003R 

 

 06-10

Summary of Contents for B200S-LF

Page 1: ...rt at systemsensor com Operating Humidity Range 10 to 93 relative humidity non condensing External Supply Electrical Ratings External Supply Voltage 16 to 33 VDC VFWR Standby Current 550 μA maximum VDC Alarm Current High volume setting 70 mA maximum 33 0 VDC Low volume setting 15 mA maximum 33 0 VDC 90 mA maximum 24 0 VDC 20 mA maximum 24 0 VDC 140 mA maximum 16 0 VDC 25 mA maximum 16 0 VDC SLC El...

Page 2: ...m the base once the tamper resist feature has been activated insert a small bladed screwdriver into the slot from the top and press down on the lever see Figure 7B This allows the detector to be rotated counterclockwise for removal The tamper resist feature can be defeated by breaking and removing the plastic lever from the base However this prevents the feature from being used again TESTING AND M...

Page 3: ... SLC EXT EXT RA SLC NOT USED SLC EXT EXT RA SLC NOT USED SLC EXT EXT RA SLC T PO E O L A SEPERATE SYNCHRONIZATION MODULE MAY BE USED TO PROVIDE THE SYNCHRONIZATION PULSES E O L HORN HORN HORN STROBE U L LISTED COMPATIBLE CONTROL PANEL UL LISTED 24V POWER SUPPLY WHEN USING 24V CONSTANT POWER AUX POWER ADDITIONAL POWER SUPERVISION RELAYS AND MODULES WILL BE REQUIRED FOR PROVIDING SUPERVISION WHEN TH...

Page 4: ...sonable use modifications or alterations occurring after the date of manufacture In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty expressed or implied whatsoever even if the loss or damage is caused by the Company s negligence or fault Some states do not allow the exclusion or limitation of incidental or consequential damag...

Reviews: