System Sensor warrants its enclosed smoke detector base to be free from defects in ma-
terials and workmanship under normal use and service for a period of three years from 
date of manufacture. System Sensor makes no other express warranty for this smoke 
detector base. No agent, representative, dealer, or employee of the Company has the au-
thority to increase or alter the obligations or limitations of this Warranty. The Company’s 
obligation of this Warranty shall be limited to the repair or replacement of any part of 
the smoke detector base which is found to be defective in materials or workmanship 
under normal use and service during the three year period commencing with the date of 
manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) 
for a Return Authorization number, send defective units postage prepaid to: Honeywell, 

THREE-YEAR LIMITED WARRANTY

12220 Rojas Drive, Suite 700, El Paso TX 79936, USA. Please include a note describing the 
malfunction and suspected cause of failure. The Company shall not be obligated to repair 
or replace units which are found to be defective because of damage, unreasonable use, 
modifications, or alterations occurring after the date of manufacture. In no case shall the 
Company be liable for any consequential or incidental damages for breach of this or any 
other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by 
the Company’s negligence or fault. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply 
to you. This Warranty gives you specific legal rights, and you may also have other rights 
which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

PLASTIC LEVER

BREAK TAB AT

DOTTED LINE BY

TWISTING TOWARD

CENTER OF BASE.

USE SMALL-BLADED

SCREWDRIVER TO

PUSH PLASTIC LEVER

IN DIRECTION OF

ARROW.

SLOT

C0144-00

C1082-01

FIGURE 7A. ACTIVATING THE TAMPER-RESIST FEATURE

FIGURE 7B. REMOVING THE DETECTOR HEAD FROM THE BASE

FIGURE 6. SYNCHRONIZATION DIAGRAM (FOR MDL SERIES SYNC MODULES ONLY)

C1090-02

NOTE: Wiring shown for System Sensor MDL Series Sync Module. For additional wiring configurations, see your sync module manual.

FACP #1

+

+

+

+

+

+

+

EOL 

(1)

}
}
}
}

HORN 

CONTROL

ZONE 1 

IN

ZONE 2 

IN

SLAVE 

IN

+

+

+

+




}

ZONE 1 

OUT

ZONE 2 

OUT

NAC 

SLAVE IN

SLAVE 

OUT

TEMP JUMP OFF

NAC 1

}

B+

B–

NAC 2

}

B+

B–

NAC 3

}

B+

B–

TO NEXT DEVICE 

OR EOL (1)

TO NEXT DEVICE 

OR EOL (1)

2 CLASS B ZONES

MASTER

SOUNDER

BASE

SOUNDER

BASE

OPTIONAL

System Sensor® is a registered trademark of Honeywell International, Inc.

NOTE:

 B200S-LF-WH and B200S-LF-IV replace the previous model number 

B200S-LF; all are functionally the same.

  

I56-4151-005 

 

 

©2018 System Sensor. 02/01/2018

firealarmresources.com

Summary of Contents for B200S-LF-WH

Page 1: ...g External Supply Electrical Ratings External Supply Voltage 16 to 33 VDC VFWR Standby Current 550 μA maximum VDC Alarm Current High volume setting 70 mA maximum 33 0 VDC Low volume setting 15 mA maximum 33 0 VDC 90 mA maximum 24 0 VDC 20 mA maximum 24 0 VDC 140 mA maximum 16 0 VDC 25 mA maximum 16 0 VDC SLC Electrical Ratings SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 μA maximum b...

Page 2: ...ble smoke sensor as described in the installation manual for the sensor CAUTION Do not over tighten mounting plate screws this may cause mounting plate to flex TAMPER RESISTANT FEATURE NOTE Do not use the tamper resist feature if the removal tool is to be used This detector base includes a tamper resist feature that prevents its removal from the base without the use of a tool To activate this feat...

Page 3: ...NAL REMOTE ANNUNCIATOR MODEL RA400Z 100Z E O L A SEPARATE SYNCHRONIZATION MODULE MAY BE USED TO PROVIDE THE SYNCHRONIZATION PULSES HORN HORN STROBE UL LISTED COMPATIBLE CONTROL PANEL UL LISTED 24V POWER SUPPLY WHEN USING 24V CONSTANT POWER AUX POWER ADDITIONAL POWER SUPERVISION RELAYS AND MODULES WILL BE REQUIRED FOR PROVIDING SUPERVISION WHEN THE SOUNDER BASES ARE INACTIVE CLASS A OPTIONAL WIRING...

Page 4: ...tial or incidental damages for breach of this or any other Warranty expressed or implied whatsoever even if the loss or damage is caused by the Company s negligence or fault Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This Warranty gives you specific legal rights and you may also have other ri...

Reviews: