V07.22
Page
13
of
20
Collectors and storage tank installation
Lift the collectors (3) on the roof. For lifting, attach two
sturdy ropes as shown opposite. During handling,
check that the rope doesn’t cover the copper inlet/
outlet tubes. It is recommended to use a crane for
lifting. If necessary, carefully use, a ladder to mount
the collectors on the roof. Work in pairs: one installer
secures the collectors, the other guides them.
Raise the tank on the roof. For assembly, attach two
sturdy ropes as shown opposite. We recommend
using a crane for lifting. Work in pairs: one installer
secures the tank, the second one guides the thank.
Observe the safety instructions! Don’t walk under
suspended loads.
Secure the collectors and the tank to prevent falls.
202INOX
Place the collector (3) on the mounting system.
202INOX
Screw the collector on the collector crossarm (4.3)
with M8 screws (5.1) and flat washers (5.3).
UP
Rear view of the
collector
3
5.3
5.1
5.3
5.1
5.3