Summary of Contents for TS-202INOX

Page 1: ...VERSION 07 22 INSTALLATIONGUIDE SolarwaterheaterThermosiphonINOX TS INOXSTTFlatRoof SystemsTS 202INOX TS 304INOXS INOX Thermosiphon Solar Water Heater ...

Page 2: ...minum laser welded on Cu tubes with 8 harp tubes Ø12mm and two manifolds Ø22mm Absorber coating Highly selective coating absorptance 95 emittance 5 Dimensions 2033 x 1015 x 98 mm 2033 x 2076 x 98 mm Net weight 31 kg 62 kg Liquid content 2 13 l 4 26 l Cover Tempered structural glass 3 2mm transmission 91 Stagnation temperature 180 C Tank BHX200 BHX300 Tank type Stainless steel 316L Stainless steel ...

Page 3: ... 2 4 11 TS Cross brace 2 2 5 Basic support Screws 1 1 5 1 Hexagon head screw M8x16 39 45 5 2 M8 nut 29 29 5 3 Flat washer M8 39 45 5 4 Grower washer M8 29 29 5 5 Anchor bolt M8 4 4 6 Hydraulics 1 1 6 1 Hydraulic tube infeed 1 1 6 2 Hydraulic return pipe with insulation 1 1 6 3 Elbowed brass compression fitting 22x18 1 2 6 4 Elbowed compression brass fitting F3 4 x18 2 2 6 5 Straight brass compress...

Page 4: ...ons TS 202INOX STT TS 304INOX STT 1570 mm 2270 mm DHW Tank Collector Solar Solar outlet Solar inlet Safety group CW inlet DHW output Thermostatic mixer Valves Pressure reducing valve Filter DHW Power supply CW 1540 mm for 25 2300 mm 1200 mm for 15 2300 mm ...

Page 5: ...l Qd QL f sol Qd QL f sol MJ a MJ a MJ a MJ a MJ a MJ a litres day 170 200 250 Stockholm 9437 3925 41 6 11103 4130 37 2 13878 4302 31 0 Würzburg 9047 4116 45 5 10643 4374 41 1 13304 4563 34 3 Davos 10243 5695 55 6 12050 5940 49 3 15063 6145 40 8 Athens 7023 5197 74 0 8263 5701 69 0 10328 6289 60 9 TS 304INOX Qd QL f sol Qd QL f sol Qd QL f sol MJ a MJ a MJ a MJ a MJ a MJ a litres day 140 170 200 S...

Page 6: ...he northern hemisphere and north in the southern hemisphere To ensure the production of hot water all year round it is possible to install an electric back up To avoid burns and for greater comfort it is necessary to install a solar thermostatic mixer How does a thermosiphon work The water circulating inside the collectors heats up expands and becomes lighter than cold water It rises naturally in ...

Page 7: ...te maintenance of the system If the roof does not allow this please consult a structural engineer Roof waterproofing In order to avoid moisture and water infiltration problems on the roof pipes that penetrate the roof must be well sealed The fixing of the supports is carried out by means of anchor bolts with sealing gasket Additional comments The connecting pipes must be very well insulated to avo...

Page 8: ... three parts 1 Installation of collectors and storage tank 2 Hydraulics 3 Maintenance Before starting the installation please consider the following points The thermosiphon solar water heater must be installed with a minimum inclination of 15 corresponding to the limit of use Antifreeze corrosion protection The TS INOX thermosiphon water heater must not be installed in areas at risk of frost ...

Page 9: ...he load bearing structure of the collectors must be earthed If a lightning protection device is already provided for the building the metal piping of the solar system must be connected to this device with a green yellow conductor cable with a minimum cross section of 6 mm Cu H07 V U or R If this is not the case an earth spike can also be used for earthing Decommissioning and dismantling The system...

Page 10: ...Page 10 of 20 V07 22 Collectors and storage tank installation View of flat roof support STT 4 for TS 202INOX View of flat roof support STT 4 for TS 304INOX ...

Page 11: ...ocks with an 8mm drill bit Tighten the soles 4 7 and 4 8 with the M8 anchor bolts 5 5 Assemble the spars 4 1 and 4 2 the rear feet 4 9 and the braces 4 10 to the corresponding soles 4 7 and 4 8 Use the screws 5 1 5 2 5 3 5 4 to make the assembly STT TS INOX 202 STT TS INOX 304 Cement blocks Minimum dimensions 200 x 200 x 200 4 7 4 8 4 9 4 10 4 2 4 1 5 1 5 3 5 4 5 2 LAYING METHOD ...

Page 12: ...k installation Put together the cross braces 4 11 to the rear feet 4 9 Use the screws 5 1 5 2 5 3 5 4 to assemble them Put together the collector crossarm 4 3 or 4 4 to the spares 4 1 and 4 2 Use the screws 5 1 5 2 5 3 5 4 to assemble them 4 11 4 3 ...

Page 13: ...taller secures the collectors the other guides them Raise the tank on the roof For assembly attach two sturdy ropes as shown opposite We recommend using a crane for lifting Work in pairs one installer secures the tank the second one guides the thank Observe the safety instructions Don t walk under suspended loads Secure the collectors and the tank to prevent falls 202INOX Place the collector 3 on ...

Page 14: ...rs with 22x22 fittings 6 6 Be careful not to overtighten the connections The collectors tappings are fragile It is necessary to use 2 flat spanners one to hold the central nut to prevent rotation of the fitting and another to tighten the nut on each side Failure to follow this protocol will result in damage to the welds and the collector 3 6 6 ...

Page 15: ...with the M8 screws 5 1 and flat washers 5 3 The cold water inlet and hot water outlet must be on the left side of the tank when standing in front of the water heater Place the tank 1 on the spares 4 1 Screw the tank crossarms 4 5 or 4 6 to the spares with the screws 5 1 5 2 5 3 5 4 Tighten all screw assemblies 5 1 5 2 5 3 5 4 1 4 5 5 1 5 3 5 1 5 3 The tank must be positioned horizontally ...

Page 16: ...ar starter G3 4 Solar inlet G3 4 Tube Ø22 Solar return Solar inlet Tank DHW Arrival CW G3 4 Tube Ø22 Solar collector 6 7 6 2 6 10 6 7 6 1 6 9 6 3 6 4 6 4 6 5 6 2 6 9 Tube Ø22 Tube Ø22 6 7 Tube Ø22 Arrival CW G3 4 Ballon ECS Solar Inlet DHW output G3 4 6 9 6 3 6 3 6 7 6 6 6 1 6 10 6 9 Solar collector Solar starter G3 4 Tube Ø22 Tube Ø22 Solar collector Tank DHW Solar inlet G3 4 6 8 6 8 ...

Page 17: ...k and collector using the compression fittings 6 3 and the loose nut 6 8 with the high temperature fibre seal 6 9 Likewise connect the return pipe 6 2 using the compression fitting 6 3 and the loose nut 6 8 with the high temperature fibre seal 6 9 Place the compression caps on the 2 remaining collector inlet outlet tubes Assemble the safety group 6 10 to the flask using a high temperature fibre ga...

Page 18: ...ctions through the roof been properly sealed Are all screws and mechanical connections properly tightened and double checked Have the safety group the pressure reducer and the thermostatic mixer been installed and their use checked Are all hydraulic connections securely tightened and has the system been checked for leaks Has the cover on the collector been removed after installation Has the protec...

Page 19: ...all the screws tight Is the tank in good condition and free of leaks or other damage Is the collector in good condition and free of leaks or other damage Is the pipe insulation in good condition Has the functionality of the valves and safety components been checked Are all hydraulic connections securely tightened and has the system been checked for leaks Does the system produce domestic hot water ...

Page 20: ... 20 V07 22 TECHNICAL DATASHEETS products accessories available on www syrius solar com SYRIUS SOLAR INDUSTRY 15 rue du Perpignan ZAC Descartes 34880 Lavérune France Tél 33 0 4 67 82 00 18 contact syrius solar fr ...