Section 1: Introduction to SY210NT V5   

1.1 Product 

Overview 

Networking Multi-Doors Controller can control 4 doors, link 8 card readers (4 IN, 4 

OUT), use 63,000 cards and 210,000 I/O data record at most.

 

(Reference 

appendix 4)

 

SY210NT V5 Network Multi-Doors Controller provides perfect functions and stable 

& reliable quality. 

* The controller can supply 63,000 people to use at most. 

* Single controller can manage 4 doors In/Out at the same time. 

* Regional Anti-Pass Back (APB) function will be activated without PC on-line. 

* The local APB will be activated in LAN. 

* The motherboard produced by the SMD technology. The quality is stable and 

reliable. 

Easy Setting 

All setting can be set by using controller keypad and LCD monitor(16x2 Char).   

You can make choice of purchase of expansion module that divides into two types: 

internal and external. 

Internal module of controller include: 

1. MDNET-2

 Ethernet Converter

 

Ethernet Communication Converter used to convert RS485 series signal 

into TCP/IP package. According to different network application types, the 

module provides two types

Server mode & Client mode. 

The module will wait for the signal from network and it will send decode 

signal to HOST CPU through series communication port under Server 

mode. The module will re-package the signal and resend on network while 

received reply from the CPU HOST. And then the command cycle will be 

done.  

User can add MDNET-2 network module to expand network function 

interface. 

2.  MDPOE-1 Ethernet Power supplier module (Power over 

Ethernet)

   

Power over Ethernet is called PoE that is the technology about power 

supply. PoE can transmit electrical power over standard twisted-pair cable in 

an Ethernet network. We can supply power from HUB by using this 

technology without connect other power source.   

3. 

MDWIE-2    (Wiegand Signal Input Module) 

After installing 4 CH Wigand signal input module (MDWIE-2

, user can 

connect four readers that include reader

fingerprint 

etc. All devices as 

mention have Wiegand interface. 

4. SD 

Card 

User can choose the SD CARD module to increase IO records or backup 

the controller data. The slot of SD CARD(MDSD-2) can compatible with the 

capacity of SD CARD include 256MB

512MB and 1GB. 

External Device of Controller: 

1. Reader

 

The Reader includes SYRDS1 Proximity Card Reader

SYRDS5 Proximity 

Card Reader

SYRDL5 Mini Proximity Reader

 SYRDT5 LCD Proximity 

Card Reader and SYRDF5/F6 Fingerprint Reader. 

System extendibility

Link 8 readers at most. The types of Reader divide into 

125K (EM)

13.56M (Mifare).

 

2. MDDIDO

 Module

 

MDDIDO Module divides MDDIDO-16 channel (16 voltage free input, 16 

relay output) and MDDIDO-1S 2 channel (4 voltage free input,

 

2 relay 

output). 

System extendibility

User can use MIDDO module expansion of system 

when first program insufficient for user need; MDDIDO Module is easy to 

expansion; e.g.    Add controller, Readers or DIDO Modules…etc. 

 

3. MDWIE-1 

(Wigand 

Module install inside of the 

Controller) 

 

MDWIE-1 Wigand Module has 2 S/N. Each number represents a channel, is 

similar to RS485 Reader; First W26Reader use first Serial NO. Reader ID 

setting( ID=1, Firs door; ID=2

Second door…..).

 

When expand the 

MDWIE-1 Module to transform the RS485 interface into the Wiegand 

interface, user can connect with each kind of devices of Wiegand interface. 

MDNET-1 

Module 

The functions are same as MDNET-2. 

4. Printer

 Module

 

Controller can connect to the following printers directly or reports printing via 

printer module. 

1. Impact Printers 2. Ink Jet Printer 3. Laser Printers 

1.2  About this Manual 

This Installation Manual provides installation and setting instructions for SY210NT 

V5. Please read this manual carefully before installing or setting the SY210NT.   

1.2.1  New in this Version   

The subject matters of the manual are focus on update of SY210NT V5: 

1.Increase the number of user

The number of user can up to 63,000. I/O records 

can up to 21,000

. (Reference appendix 4) 

 

2.The time of door open by hand is longer

The time can be set as 9999 seconds or 

above. 

3.Backup SD Car

d:

The types of backup are Manual /Automatic. The backup / 

restore set can up to 10 sets. 

4. Invalid password entering event handl

e:

User can set times or lock time while 

error password input (1~999 sec). 

1.2.2  Fast Setting Index Sheet and Card Record Sheet 

User can find out a setting location by referring the “Quick Reference Programming 

Table”, 

appendix 1

User can print and record Card Information by using 

appendix 3.

.  

1.3 Features 

1.  Internal extension Module optional

 

(a)  

10/100M

 

Ethernet Converter

MDNET-2

(b)  

4CH

 

Wigand Signal Input Module

MDWIE-2

(c)  

SD Card module (MDSD-2 applies SD Card whose memory size of 

256MB

512MB

1GB). 

(d)  

POE

 

Power over Ethernet Module (MDPOE-1,Client). 

2.  The controller can be run with the software: SYW95A-V832.11

V2

V3

SYW95A 

-V2-NET and SY-SOFT-95A. 

3.  User can adjust the number of cards and record capacity of I/O data according to 

need. 

4.  Promote number of User/Card and I/O data record

If using the new version of 

SY-SOFT-95A, the card/user capacity can increase to 21,000; High-capacity 

Device can promote number of User/Card to 63,000 and promote I/O data records 

to 210,000 at most. The whole speed of CPU promotes to 100 MIPS. (Reference 

appendix 4

). 

5.  After installing SD Card Module and SD Card, user can

 

backup all data from the 

controller.  

6. Fast update firmwar

e:

Support to update the firmware on-line through RS485 or 

Ethernet. 

7.  While Ethernet network module is added, the communication styles to HOST-PC 

are polling and auto-transmission. Both of the polling and auto-transmission can 

run at the same time. The system provides not only efficient transmission but also 

response event immediately. While more and more doors in system, the excellent 

functions will be presented. 

8.  The system will send commands to related controller and modules to active fire 

control and fire alarm automatically through Ethernet converter. The functions also 

can be handled through client PC. 

1.4 Specifications

 

Number of Cards—

3,500 ~ 63,000; 

Number of Readers—

 8 (4 IN, 4 OUT); 

I/O Records—

21,000~3500

 (Reference appendix 4)

Control Doors—

 4 Door; 

Output— 

4 relay; 

Input—

 8 points; 

LCD Display—

 16 

×

 2 LCD; 

Indicator—

 8 LED; 

Reader Technology—

 SYRIS RS485 format; 

User PIN— 

4 digital codes; 

Communication ports—

 RS485 

×

  2

Optional 10M/100M Ethernet; / 802.11b 

WiFi 

Baud Rate—

 Default 19,200bps, 4,800

9,600

19,200

38,400

57,600

115,200

Summary of Contents for SY210NT V5

Page 1: ...rmation on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read SYRIS Technology Corp 21F 2 NO 12 Sec1 Taijunggang Rd Taichung Taiwan 403 Tel 886 4 2207 8888 Fax 886 4 2207 9999 Email info syris net ...

Page 2: ...d 7 4 2 3 Delete Card 7 4 2 4 Show Card 7 4 2 5 All Card APB Setting 7 4 3 FINGERPRINT MANAGEMENT 7 4 3 1 Add Fingerprint 7 4 3 2 Delete Fingerprint 7 4 3 3 Delete All Fingerprint 7 SECTION 5 SET UP SY210NT V5 STEP BY STEP 7 5 1 CONTROLLER FUNCTION 7 5 1 1 Set Controller ID 7 5 1 2 Same Card Time 7 5 1 3 Invalid Password Lock 7 5 1 4 Baud Rate Setting 7 5 1 5 DI Setting 7 5 1 6 Elevator Mode 7 5 1...

Page 3: ...MING TABLE 11 APPENDIX 2 PROGRAMMING WORKSHEET 12 APPENDIX 3 CARD INFORMATION RECORD SHEET13 APPENDIX 4 SY210NT V5 CARD CAPACITY AND I O DATA LIST 14 APPENDIX 5 USING THE SY210NT SYSTEM 15 Q1 How to setting reader ID What Reader ID and are Door relate 15 Q2 How to add the card 16 Q3 How to setting the push button from controller 16 Q4 How to Connect HID Readers of Wiegand interface with Controller...

Page 4: ...er ID setting ID 1 Firs door ID 2 Second door When expand the MDWIE 1 Module to transform the RS485 interface into the Wiegand interface user can connect with each kind of devices of Wiegand interface MDNET 1 Module The functions are same as MDNET 2 4 Printer Module Controller can connect to the following printers directly or reports printing via printer module 1 Impact Printers 2 Ink Jet Printer ...

Page 5: ... or RS232 Relay connection Relay connects with electromagnetic lock 2 2 Selecting a Mounting Location Select a mounting location for the unit using the following guidelines z Next to the door that is being supervised z To avoid setting controller in huge noise areas z It is recommended that setting up location should be visible for flashing card to access easily The height of setting location shou...

Page 6: ... Setting Same Card Time The period means flashing one card twice or continuous Setting Invalid Password Lock While user input invalid password over setting times the system will lock down User can t input when system lucked Setting Comm Baud rate Communication Baud rate 4A 4R Default is 19200 e 8 1 Setting DI Setting The NO NC settings of DI are in control and module Setting Elevator Mode Enable e...

Page 7: ...e System Controller Keypad LCD display Annotation or MENU Controller Same card time EN Same card time 000 sec Using numeric keypad input setting value 5 1 3 Invalid Password Lock System Controller Keypad LCD display Annotation or MENU Controller PIN lock EN Error number 3 Using numeric keypad input setting value EN Lock time 060 sec Using numeric keypad input setting value 5 1 4 Baud Rate Setting ...

Page 8: ...etting System Door Door 1 4 Keypad LCD display Annotation or MENU Door APB setting EN APB setting Level 0 Using numeric keypad setting level 0 3 5 4 Master Card Function Setting Keypad LCD display Annotation MENU Login EN Password _ _ _ _ _ _ _ Using numeric keypad input password EN Master Ok Login success or MENU Master 5 4 1 Master PIN Setting System Master 按鍵 顯示畫面 備註 or MENU Master PIN setting ...

Page 9: ...d or MENU Add Card By No Using choice By serial or By No EN Add Card No 01000 Using numeric keypad input number EN Punch card Please punch the card can punch card continuously NOTE The manual serial number increases the card commonly used in to increase some specific serial number the card If punch card continuously the number will from input number starts to increase EX Input number 1000 when pun...

Page 10: ...N Fingerprint Add After the bi bi voice press the fingerprint to press on the fingerprint sensor The bright OK green light expresses successfully EN Fingerprint No 0002 Add fingerprint or use CLR exit 5 7 2 Delete Fingerprint Login Fingerprint Fingerprint ID X Keypad LCD display Annotation or MENU Fingerprint Delete EN Fingerprint No 0001 Using numeric keypad input fingerprint number EN Fingerprin...

Page 11: ...tect 2 ID setting 3 Door 1 Relay 2 Push button 3 APB setting 4 Master 1 PIN setting 2 Add card 3 Delete card 5 System Utility 1 Date setting 2 Time setting 3 Reboot 4 Backup Restore 5 System Initial 2 Card 1 Add card 1 By serial 2 By no 2 Edit card 1 Status 2 PIN 3 APB 3 Delete card 1 By no 2 All 4 Show card ID 5 All card APB setting 3 Fingerprint 1 Fingerprint Add 2 Fingerprint Delete 3 Fingerpri...

Page 12: ... ____ PIN Lock Error Number 3 ____ PIN Lock Time 60 sec ____sec Baud Rate 4A 19200 e 8 1 ________ __ __ __ Reader Baud Rate 4R 19200 e 8 1 ________ __ __ __ Elevator Mode No ____ Max Card 10500 ________ Door Relay ID 0 0 0 0 CH 01 02 03 04 ID _ _ _ _ CH __ __ __ __ Relay Time 005 sec __ __ __ __ sec Push Button ID 0 0 0 0 CH 00 00 00 00 ID _ _ _ _ CH __ __ __ __ APB Setting Level 0 0 0 0 Level __ ...

Page 13: ... I______I______I______I______I______I______I______I______I I______I______I______I______I______I______I______I______I I______I _____I______I______I I I I______I______I______I______I______I______I______I______I I______I______I______I______I______I______I______I______I I______I _____I______I______I I I I______I______I______I______I______I______I______I______I I______I______I______I______I______I_____...

Page 14: ...0 17500 7000 101500 7000 213500 10500 14000 10500 98000 10500 210000 14000 10500 14000 94500 14000 206500 17500 7000 17500 91000 17500 203000 21000 3500 21000 87500 21000 199500 24500 84000 24500 196000 28000 80500 28000 192500 31500 77000 31500 189000 35000 73500 35000 185500 38500 70000 38500 182000 42000 66500 42000 178500 45500 63000 45500 175000 49000 59500 49000 171500 52500 56000 52500 1680...

Page 15: ...The module can differentiate as follows READER Proximity Card Reader Have SYRDS1 SYRDS5 SYRDL5 and MDWIE DIDO Extend Module Have MDDIDO 1S and MDDIDO 16 PRINT Printer Module SYRDK5 Keypad Proximity Reader SYRDF5 F6 Fingerprint Reader SYRDT5 LCD Proximity Card Reader Note 2 User can find the serial number on the packing box or serial number label at the back of device Note 3 Readers ID alignment ru...

Page 16: ... Punch Card Card Use If the card has already used system would appear a message Card Use CLR Add Card By Serial Q3 How to setting the push button from controller A3 Controller DI1 is push button of Door 1 Keypad LCD display Annotation MENU Login EN Password 1234_ _ _ _ Using numeric keypad input password EN Master OK The Setup lamp signal is bright Setup Login success 2 System EN Controller 2 Door...

Page 17: ...k Wir e Re d Wir e GND BLACK D1 GREEN D0 WHITE GND BLACK D1 GREEN D0 WHITE 12V GND 4R 4R Yellow Wire Green Wire Bla ck Wire Re d Wir e GND BLACK D1 GREEN D0 WHITE GND BLACK D1 GREEN D0 WHITE H I D H I D H I D H I D ID 1 ID 5 ID 2 ID 3 M4 M2 M3 M5 Blue Wire Violet Wire Gray Wire White Wire Black Wire 4A 4A 4R 4R GND Magnetic sensors Door sensors Note 4A and 4A are used to connect to other controlle...

Page 18: ...rter DI3 DI4 GND Yellow Wire Green Wire Black Wire Break glass switches GND 4R 4R Yellow Wire Green Wire Black Wire 12V Red Wire DI1 Brown Wire DI2 Orange Wire DI1 DI2 DI3 DI4 GND Brown Wire Orange Wire Yellow Wire Green Wire Black Wire Exit Buttons COM1 NO1 COM2 NO2 Brown Wire Orange Wire Yellow Wire Green Wire Blue Wire Violet Wire 12V Red Wire GND 4R 4R Yellow Wire Green Wire Black Wire M5 M3 M...

Page 19: ...Setup Login success 2 System EN Controller 2 Door EN Door No 1 1 Expresses the Door1 1 Door Push button Door Push button setting EN Push button ID 1 CH 01 DI setting ID 0 Indicate to be in use expansion module1 CH 01 Indicate to be in use channel 01 EN Door Push button Presses the EN key to confirmation CLR 3 2007 12 30 Sun 17 52 53 Setting success ...

Page 20: ...ire 藍色 Green Wire 綠色 Yellow Wire 黃色 Orange Wire 橙色 Brown Wire 棕色 Can be Door sensor Push button or other NC NO output sensor Digital Input 輸入接點 Connect to SYLINK and other Controllers Reader Reade r DIDO Printer Modul e 連結 SYLINK 與 其它控制器 Green Wire 綠 色 Yellow Wire 黃色 Orange Wire 橙色 Brown Wire 棕色 Black W ire 黑 色 Blue Wire 藍色 4A Violet Wire 紫色 4A Gray Wire 灰色 4R White Wire 白色 4R Black Wire 黑色 GND DI...

Reviews: