Operation 

 
Stages and Banks 
The sequential controller can be configured as one bank of 24 stages, or 3 individual banks of 8 stages 
each.  Each bank has its own voltage output which is set manually, and a gate output.  The output voltage 
range is selectable: 0/+5 volts or -5/+5 volts. An LED indicates which stage is active.  
 
Master Output 
A master output is also provided that adds features including Glissando also known as Portamento or 
slew limiting, manual voltage adding, and external voltage adding, and an LED indicating the Gate output 
status.  When in 3x8 mode (3 banks of 8 stages) the master output adds together voltages from the three 
output banks.  
 
Gate Outputs 
Each Bank has its own gate output (normally only used when in 3x8 mode), and there is a master gate 
output (normally only used when in 1x24 mode).  The width of these gate signals are determined by a 
single front panel control.  The width can be controlled from approximately 10% to 90% of the stage's on 
time.  Individual gate outputs for each stage are not provided.  
 
Triggering 
The sequential controller can be triggered (started and stopped) manually or by external triggers from 
oscillators, envelope generators, keyboard gates, etc.  Several options exist including a level sensitive 
'Go' input that causes the sequencer to start on the rising edge of a signal and stop on the falling edge.  
The 'Start' and 'Stop' signals can be used to control the sequencer with individual signals for each, or in 
conjunction with the 'Go' signal.  This configuration gives you great control over how the sequencer be-
haves.  For example: if you would like the sequencer to only be on when a key is pressed from the key-
board, connect the keyboard's gate output into the 'Go' input.  If you would like the sequencer to start, 
simply press the 'Start' button.  To create 3 complex envelopes in response to a key press, select 3x8 
mode, and connect the keyboard's gate output into the 'Start' input, and set the 'Cycle' switch to 'Once'.  

The Q119 Sequential Controller (Sequencer) creates a series of signals at a rate determined by an inter-
nal oscillator or external source.  Normally used to create loops of sounds, effects, arpeggios, or complex 
envelopes.  

Summary of Contents for Q119

Page 1: ...me Individual gate outputs for each stage are not provided Triggering The sequential controller can be triggered started and stopped manually or by external triggers from oscillators envelope generators keyboard gates etc Several options exist including a level sensitive Go input that causes the sequencer to start on the rising edge of a signal and stop on the falling edge The Start and Stop signa...

Page 2: ...on Manual or from gates signals GO runs sequencer as long as button or signal remains high on Mode Control Section 8 stage or 24 stage Output range contrl Cycle Once or Continuous Up or Up Down motion SET END Sets the last stage in the sequence Oscillator Control Section Speed control and internal external selection Use square wave or gate Manual Stepping GATE WIDTH Controls duty cycle of All Gate...

Page 3: ...helpful when setting the stage controls A switch is provided to select an external oscillator source which can be driven by the Q106 Oscillator keyboard gate pulses etc It is possible to have each stage active for a variable amount of time by using an external Q106 Oscillator which is controlled by one of the bank outputs Length Selection The number of stages in a sequence is set by a front panel ...

Page 4: ...s Gate Width Control Adjusts the gate width from approximately 10 to 90 This affects all gate outputs Go Button Connector This is a level sensitive signal used to control the on off status of the sequencer Pressing and holding this button or applying a signal will cause the sequence to begin assuming other controls are set cor rectly and releasing it will stop the sequence For example to have the ...

Page 5: ...A gate output is provided when a stage is on Gate signals are 0 volts when off 5 volts when on Master Output Section The master output section is important when in 1x24 mode Master Output Connector The selected stage voltage is routed to the output connector When in 3x8 mode all 3 stage s voltages are added together mixed and presented at the master output connector The Add connector voltage and t...

Page 6: ...Turn each stage s knob and insure the voltage is changing accordingly During this test move the Output s switch to both positions and verify that the voltage range is obtainable 3 Attach a volt meter to the master output connector and verify that changing the Add control affects the voltage Also apply a voltage to the Add input and verify that it affects the master output 4 Select Internal oscilla...

Page 7: ...Q119 Sequential Controller Aug 2014 PC Board Layout ...

Reviews: