Q106
Oscillator
Jun 2014
Specifications
Panel Size: Dual width 4.25"w x 8.75"h.
Response: 1/V-per-Octave
Frequency Range: .05hz to 20khz
Power: +15V@30ma, -15V@30ma, +5@5ma.
Output Waveforms: Sine, Triangle, Saw, Ramp, Pulse.
Waveform Levels: 10V PP
Sine Waveform THD: 3%
Pulse Waveform Duty Cycle: 5% to 95%
Q141 Oscillator Aid
Use the Q141 aid module next to your Q106 oscillator for additional functionality including a soft sync input
with amount control, waveform selector, amplitude adjustment, and inverted outputs.
Tracking Accuracy
Tracking accuracy determines how closely your oscillators track the keyboard. Human hearing is very
sensitive to pitch and some people can discern differences as low as .2%. Tracking is most important on
frequencies from 32hz to 4096hz (7 octaves). We think this is the most important parameter of an oscilla-
tor.
Test Equipment Used (all have recent calibration):
HP 5335a 9 Digit Frequency Counter
Fluke 3330b Voltage Calibrator
Desired
Actual
% Error
32Hz
32.07hz
+0.22
64hz
64.16hz
+.25
128hz
128.2hz
+0.16
256hz
256.2hz
+0.08
512hz
511.9hz
-0.02
1,024hz
1023.2hz
-0.08
2,048hz
2046hz
-0.09
4,096hz
4094hz
-0.05
8,192hz
8236hz
+0.5
16,384hz
16778hz
+2.3
Please see the website for