background image

                        B01-NOT-DRIVER-03 

Generation II Driver Notifications

 

Notifications 

V1.2 

Dear  users,  please go  through  the  instructions  in detail  before  the  installation. Also, 

please hand the manual to the actual operator of the machine and preserve it properly. 

Drivers  are  precision  electronic  devices.  For  the  safety  of  both  operators  and  the 

machine, please ensure all installations, tests and adjustments are operated by professional 
personnel. For the description with “

DANGER

”, “

WARNING

” and “

CAUTION

” in the manual, 

please read them in detail. If there are any concerns, please contact our branches in your 
region.  Our  professionals  are  glad  to  be at  your  service.  The  following  are the guidelines 
you should comply with before finishing reading the complete manual: 

 

The  installing  environment  should  be  indoor  and  without  water  vapor,  corrosive  or 

flammable gas. 

 

Implement the wirings according to the wiring diagram. 

 

The grounding must be strictly implemented and follow the current National Electrical 
Code. (References: NFPA 70: National Electrical Code,2005 Ed.) 

 

Do not modify the wirings while the device is powered up. 

1.

 

Safety Precautions 

 

2.

 

Installation Notifications: 

 

The leakage current of an all-in-one driver is usually over 3.5 mA. In accordance with 
EN 61800-5-1, fixed installation is required. 

 

The  direction  of  the  installation  must  be  in  accordance  with  the  regulations, 
otherwise it will cause servo failures. 

 

When installing the driver, the air intake and vent holes should not be sealed, and the 

driver should not be tipped; otherwise it will cause malfunctions. 

 

Do not install the driver near flammable materials. 

 

Ensure every mounting hole is locked up when fixing the driver. 

 

Ensure the installation surface can support the weight of the driver. 

 

3.

 

Wiring and Other Notifications 

 

When using a solenoid valve or other inductive loads, please apply an arc extinguisher 
or  an  RC  voltage  dependent  resistor  to  ensure  the  life  of  the  contact  points. 
Advantages of the arc extinguisher: 

1) Extend the life of electrical contacts. 

2) Reduce the sparks from the contact points. 

3) Prevent the inductive loads from interferences caused by back EMF. 

4) Restrain the impulse voltage. 

 

Do not connect other cables to extend the original length. It might cause signal errors 

or malfunction. 

 

Please crimp or weld the wire connections while doing the wirings.   

 

If the  servo  line  in  use  is  not  a  standard  Syntec cable,  please  verify all the terminals 

are connected properly before power-on. Wrong wirings will lead to controller output 
command errors and malfunction.   

 

The +5V output capacity of the encoder is 500mA and is only for a single encoder. Do 

not connect it with other loads or it might cause error due to the lack of driving force.   

 

Do  not  use  counterfeit  terminal  strips.  Those  terminal  strips  cannot  provide  overall 
protection  for  the  system.  The  quality  is  also  not  guaranteed  and  tend  to  cause 
electrical control problems of the machine tools 

 

Do not stake on top. 

 

The six power lines, R, S, T and U, V, W, should not be close to other signal lines, and 
should be at least 30 cm apart. 

 

After cutting off the power, the capacitor of the driver still  contains large amount of 
charge. Do not touch the 6 power lines, R, S, T and U, V, W, until the power indicator 

goes out. 

 

If  the  encoder  line  should  be  longer,  please  use  twisted-pair  and  signal  cable  with 
isolated  ground.  Do  not  extend  it  over  20  meters.  In  case  of  extensions  over  20 
meters, please double the wire diameter of signal cables to reduce signal attenuation. 

 

The driver is fragile. Please handle it with care. 

 

Do not allow conductive foreign matter such as screws or metal chips, or combustible 

foreign matter such as oil enter the driver. 

 

Applicable motor types

Please refer to the catalogue. 

 

It  is  suggested  that  M3  communication  and  encoder  cables  be  hung  loosely  (Left 
Figure). If bundling is needed (Right Figure), please leave at least 100mm between the 

M3 wire connector and the bend to avoid poor contact of the connector.   

 

(Hang loosely)              (Tied up) 

 

 

 

 

 

 

 

 

 

 

 

 

Please follow  the  wire  diameter  regulations.  The  suggested  choice of  wire  diameter 

varies with the motor wattage. Please refer to the table below

 

Type 

Wattage 

Wire Diameter 

Axial 

100W~850W 

20AWG 

850W~7.5kW 

16AWG 

Spindle 

Below 7.5kW   

12AWG 

Above 11kW 

10AWG 

 

Please connect the ground wire to class-3 (under 100Ω). Poor grounding might cause 

signal error, electric shock, or fire. 

 

The grounding of the motor must be connected to one of the grounding terminals of 
the frequency converter.   

 

In accordance with EN 61800-5-1 (Section 4.3.5.5.2), since the normal contact current 

 

Please pay extra attention to the instructions below while operating the product.

 

 

 

Install  the  driver  according  to  the  instructions  in  the  manual  or  it  might 

cause damage to the equipment. 

 

Do not operate the product in places exposed to water vapor, corrosive or 

flammable  gases.  It  might  cause  damage  to  the  device,  electric  shocks, 
fire or explosion. 

 

Do not install the product at a temperature exceeding the specified range. 

It might cause device damage or malfunctioning. 

 

The  driver  series  are  designed  to  control  the  motors.  Do  not  touch  the 

internal circuits or parts while the driver is powered up. 

 

The  internal  circuit  board  of  the  driver  contains  CMOS  ICs,  which  are 

vulnerable  to  static  electricity.  Do  not  touch  the  circuit  board  with  your 
hands before taking any precautions. 

 

The product has been certified by EN 61800-5-1/EN 61800-3. It is for use in 

industrial environments. 

 

Do not apply the product to machines that might lead to casualties, device 

damage or system shut down. 

 

 

Please cut off all the external device loads when powering up the driver for 

the first time in case the built-in testing program starts running the motor 
immediately  after  power  input.  It  may  be  dangerous  for  the  operators 
around. 

 

The driver is a precision instrument. Please prevent non-maintenance staff 

or  non-professional  electronic  control  personnel  from  disassembling  the 
device. 

 

Please apply the correct ground loop to prevent signal errors. 

 

Please  separate  the communication cable of  the  driver  from  all  the  other 

motor  and  power  cables  with  individual  wiring  ducks  to  prevent  the 
controller from malfunction caused by large noise interference. 

 

 

The  driver  adopts  microcomputer  design.  Please  install  the  driver  in  a  safe 
area  and  keep  the  area  clean.  Please  keep  iron  shavings,  wires,  water, 
corrosive gas and liquid from the driver to avoid malfunctioning. 

 

Please reserve at least 50mm in width for ventilation and heat dissipation. 

 

The grounding of the driver and machine tool system is necessary for leakage 
protection  and  prevention  of  lightning  strikes.  Please  ensure  the  driver  and 
the machine tool system are grounded properly before installing. 

 

The  power  system  of  the  driver  should  meet  the  rated  voltage.  If  the 
operating  environment  provides  an  unstable  voltage  source,  please  apply  a 
voltage stabilizer so that the driver can function properly. 

 

Please  turn  off  the  power  before  plugging/unplugging  the  cables  or 
modifying the wirings to prevent electric shocks or damage to the driver. 

 

Please make sure all the terminals are in the correct positions while wiring to 
prevent the driver from damage caused by wiring mistakes. 

 

Do not touch the terminals within 10 minutes after cutting off the power in 
case that the residual voltage might cause electric shocks. 

 

Unload the driver after the driver is powered off after 30 minutes. 

 

To  ensure  communication  quality,  the  length  of  USB  extension  cords  in  use 
shall not exceed five meters. Besides, do not charge or supply power via the 
USB port; otherwise, it may cause controller malfunction. 