background image

ABOUT THE PRODUCT

Synetik ErgoCare’s patented Vertiflex 60 Standing Frame is designed to provide added positioning 
assistance to the user. Supports and pad dimensions are adjusted specifically to meet the 
anthropometric measurements provided by the therapist. This growth extension can be done at time 
of delivery of the standing frame to ensure a proper fit for the user.

The Synetik ErgoCare Vertiflex 60 Standing Frame enables the user to remain upright, facilitating 
blood circulation, digestion and muscle development. In addition, the abduction option further 
reinforces a user’s lower limb capacity by reducing the risk of aggravating any hip problems which 
can be brought on by prolonged periods of sitting or lying down. Being in an upright position also 
allows the user to socialize more easily with their peers and tends to promote their physical and 
psychological development.

The Vertiflex-60 is easy to use in a variety of contexts and environments such as at home, in childcare 
settings as well as at school. The Vertiflex 60 can be used in either a prone or supine position. This 
standing frame is also available in a hybrid model, which offers both a prone and supine positioning
capability within the same product.

 

 IMPORTANT

Read the User Guide carefully before using the device for the first time and keep the Guide for future 
reference.

 

 SAFETY INSTRUCTIONS

The use of the Vertiflex 60 Standing Frame must follow the recommendation and adjustment by a  
specialized therapist.
Ensure that all accessories used are approved by Synetik as recommended.
Ensure that all persons handling the standing frame are familiar with its operation and have read 
the User Guide.
Never leave the user unattended while in the device.
Make sure all straps are securely fastened before standing the user up in the device.
Never add any weight other than that of the user to prevent the equipment from tipping.
Always lock the wheels when the device is not moving.
Make sure the standing frame is on a smooth, level surface.
Never move the equipment when the user is in it.
Never attempt to modify the product. Use only parts approved by Synetik ErgoCare otherwise the  
safety of the user may be jeopardized, and the warranty will be voided.
If unsure about the safe use of the product, stop using it and contact Customer Service.
Some parts of the standing frame may be a choking hazard for children. Always make sure that 
parts are securely fastened to the product.







Summary of Contents for Vertiflex 60

Page 1: ...60 U S E R M A N U A L ...

Page 2: ......

Page 3: ...e in a hybrid model which offers both a prone and supine positioning capability within the same product IMPORTANT Read the User Guide carefully before using the device for the first time and keep the Guide for future reference SAFETY INSTRUCTIONS The use of the Vertiflex 60 Standing Frame must follow the recommendation and adjustment by a specialized therapist Ensure that all accessories used are ...

Page 4: ...ge Never use the standing frame for transport in a vehicle CLEANING AND MAINTENANCE An inspection of all moving parts adjustment knobs and levers must be done regularly to avoid a decrease in adjustment tension Please refer to Daily Inspection section for additional details on daily safety maters To clean use soapy water and a soft cloth DECLARATION OF CONFORMITY Synetik ErgoCare warrants and decl...

Page 5: ...n soft floor 2 Once all supports axilla thoracic hip and knee are properly freed install the user in the product laying down and then fix all supports to securely maintain the user a Transfer of user in and out of product must be performed by a trained professional or authorized caregiver b Transfer techniques might differ from one user to another based on their medical condition ABOUT THE PRODUCT...

Page 6: ...draulic cylinder fig 3e Loosen the set screw located under the block beneath the footrest fig 3b Slide sideways to the desired width and then retighten with the Allen key For angle adjustment of the footrest use the adjustable lever fig 3d To do this you will need to lift the lever slightly and then turn clockwise to tighten and counter clockwise by raising it to reposition the lever in the proper...

Page 7: ... wing knobs Slide to the required width then retighten fig 7b 8 THORACIC SUPPORT ADJUSTMENT To adjust the height of the thoracic supports loosen the two knobs located in the upper part of the core fig 8a Slide the top part of the support up or down to the desired height and retighten To adjust the width of the thoracic supports loosen the two knobs on each side of the core and slide sideways to th...

Page 8: ...he adjustable lever For depth adjustment of the tray loosen the two knobs on each side located under the tray on the inner section of the angle adjustments fig 11e Slide the tray on its glides to the desired location and retighten the four knobs 12 STRAP ADJUSTMENT Some supports are anchored using a Velcro strap to facilitate positioning of the user Insert the strap into the metal loop and fold th...

Page 9: ...al or replacement parts can be done through a Synetik ErgoCare s authorized representative or via our customer service DAILY INSPECTION OF VERTIFLEX 60 STANDING FRAME Synetik ErgoCare recommends that a daily visual inspection be performed by a therapist parent or caregiver to ensure the safe use of the product In order to perform the daily inspection of the Vertiflex 60 Standing Frame you will nee...

Page 10: ...mum Minimum Maximum Maximum Maximum Size 34 50 in Max weight 70 lb Size 45 72 in Max weight 150 lb 10 5 5 5 1 5 5 15 10 10 10 3 5 12 75 15 7 8 5 5 2 5 5 22 14 12 14 4 12 75 22 12 10 5 5 2 5 5 34 18 20 18 5 5 17 SELECTION CHART CHEST SHOULDER SUPPORT BASE FOOT SUPPORT KNEE SUPPORT HIP SUPPORT THORACIC SUPPORT HEADREST TRAY ABDUCTION SUPPORT ...

Page 11: ...x 8 3 x 5 3 x 5 3 x 5 5 x 6 5 x 10 6 x 8 6 x 12 7 x 10 7 x 14 8 x 12 8 x 16 10 x 16 2 X 5 3 X 6 3 X 6 3 X 8 4 X 9 4 X 10 4 X 12 5 X 13 10 x 20 13 x 18 13 x 22 3 x 6 3 x 6 3 x 6 3 x 7 3 x 7 3 x 7 4 x 8 4 x 8 4 x 8 4 x 3 4 x 3 4 x 3 4 x 4 4 x 4 4 x 4 4 x 4 4 x 4 4 x 5 4 x 5 4 x 5 4 x 5 4 x 5 4 x 6 4 x 6 4 x 6 4 x 6 4 x 6 4 x 7 4 x 7 4 x 7 4 x 7 4 x 7 5 x 5 5 x 5 5 x 5 5 x 5 5 x 5 5 x 6 5 x 6 5 x 6 5...

Page 12: ...1242 de Lanaudière Joliette Quebec Canada J6E 3P1 1 450 752 8818 Fax 450 752 1644 www synetikergocare com CONTACT US Rev 2 ...

Reviews: