PROGRAMMING
Menu Level 2: Power Save Mode Setup
Line 1 indicates that you are on the Power Save Mode screen.
Line 2 of the Power Save Mode in this example is indicating the timers are [ENABLED], making
adjustments to lines 3 and 4 available. If line 2 reads [DISABLED], no further programs will be
available on this screen.
Line 3 indicates the settable time at which your power save mode will start.
Line 4 indicates the settable time at which your power save mode will end.
Enabling the power save mode will drop the temperature in the brew group(s) to 180F (82.2C) and
the steam tank to 220F (104.4C) for the time span set. This will help conserve energy while
preventing maintenance issues that occur due to depressurizing and re-pressurizing, when machines
are turned off and on. This will also allow the machine a shorter amount of time to reach full
temperature and stabilize, after the power save mode has ended. We suggest using this feature only
if the machine can be in power save mode for more than
3 hours
at a time.
To cycle to the next display screen press the button to the left of line 1.