HYDRAULIC SYSTEM
MAjOR COMPONENTS OF THE WATER INLET SYSTEM (CONT.)
Steam Inlet Check Valve:
See Brew tank check valve description. (Page 22).
Steam Inlet Water Control Valve:
When the
upper level probe (Page 25)
detects an absence of water, the control board will
send a signal to open this valve and allow water into the steam tank. 1st generation machines have a
manual fill switch to open this valve at the operator’s discretion in addition to the autofill system.
Steam Tank Inlet Fill Line:
(
Combined with Brew Inlet on single inlet machines)
)
This is the incoming 3/8” steel braided line which supplies the steam tank with water. May be
labelled with a pink tag on Hydras.
Vacuum Breaker
:
Prevents steam tank pressure from dropping below atmospheric pressure. As the tank heats,
the pressure from the steam pushes an internal rod and o-ring up, sealing the vacuum breaker. When
the tank cools below the boiling point, steam will condense and shrink in volume potentially pulling a
vacuum in the steam tank. At this point, the internal rod and seal will drop down and allow air into the
tank to replace the cooling steam, preventing a vacuum.
2014 3 Group Hydra Inlet (right) side
Summary of Contents for Cyncra
Page 1: ...Technical Manual ...
Page 9: ...9 INSTALLATION ...
Page 19: ...HYDRAULIC SCHEMATIC SINGLE INLET 19 ...
Page 20: ...HYDRAULIC SCHEMATIC HYDRA 20 ...
Page 31: ...31 ELECTRICAL SYSTEM ELECTRICAL SCHEMATIC ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...