Synapse DAD08 Manual Download Page 13

11 

6  Status Menu 

Introduction 

The status menu indicates the current status of each item listed 
below. 

 

 

Error 

The 

Error

  status item indicates the current condition of the 

audio being processed. The errors have a priority associated with 
their error code, with validity having the lowest priority and no 
lock having the highest priority. Since only one code can be 
displayed, the error with the highest priority that occurred since 
the last clearing will be visible. 

This item can have the following status; 

No Error

: The digital audio signal has no errors. 

Validity Bit High

:  Indicates that the validity bit for a 

previous sample was high since the last clearing of the error 
codes. 

CRC Error

: This error is indicated when the CRC value does 

not match the CRC byte of the channel status block or when a 
block boundary changes (as in removing samples while editing). 

Parity Error

: The parity error occurs when the incoming 

sub-frame does not have even parity as specified by the standards. 

Bi-phase Error

: The bi-phase coding error indicates a bi-

phase coding violation occurred. 

No Lock

: This error message indicates that the PLL is not 

locked onto the incoming data stream. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DAD08

Page 1: ...___________________________________________ DAD08 09 Digital Audio Distribution Amplifier...

Page 2: ...Lange Wagenstraat 55 NL 5126 BB Gilze The Netherlands Phone 31 161 850 450 Fax 31 161 850 499 E mail Info axon tv Web www axon tv TECHNICAL MANUAL DAD08 DAD09 Digital Audio Distribution Amplifier...

Page 3: ...o extremely high or low temperatures NEVER operate this product in an explosive atmosphere Warranty Axon warrants their products according to the warranty policy as described in the general terms That...

Page 4: ...Quick Start When powering up Default settings Changing parameters and settings Front Panel Control Example of changing parameter using Front Panel control Synapse Setup Software Menu Structure Example...

Page 5: ...ocal control panel is also used to back up and restore card settings Please refer to the rack controller manuals RRCxx RRSxx ERCxxx and ERSxxx for a detailed description of the local control panel the...

Page 6: ...ature failure from components mounted on the board Placing the card The Synapse card can be placed vertically in an SFR18 frame or horizontally in an SFR04 and SFR08 frame Locate the two guide slots t...

Page 7: ...ers The front panel controls or the Cortex Software can be used to change settings An overview of the settings can be found in chapter 5 6 and 7 of this manual Front Panel Control Front Panel Display...

Page 8: ...to indicate that the SFS10 Settings menu item SDI Format has been selected and shows that it current setting is Auto Pressing the selects the settings item shown in this example SDI Format Pressing or...

Page 9: ...address giving access to each module its menus and adjustment items Cortex has access to data contained within the Synapse module and displays it on a GUI The software has an intuitive structure foll...

Page 10: ...96 kHz are indicated Signal Status Indication Signal status and error messages included in the audio data format are decoded and displayed I O Flexibily The DAD08 and DAD09 offer a wide range of inpu...

Page 11: ...tor panel similar to the BPL01 with a back up facility to connect J1 with J4 in a card or power failure situation Also an all D Sub version can be used The BPL05D Fiber backplane with unbalanced In Ou...

Page 12: ...control and Cortex software Validity bit This setting sets the validity bit in the AES audio stream The validity bit is 0 if the audio sample word is suitable for conversion to an analog audio signal...

Page 13: ...the following status No Error The digital audio signal has no errors Validity Bit High Indicates that the validity bit for a previous sample was high since the last clearing of the error codes CRC Er...

Page 14: ...the announcement of status changes on off 0 off other on Input Input can be selected between 0 255 0 no event 1 255 is the priority setting What information is available in an event The message consis...

Page 15: ...ined for the DAD08 09 are Event Menu Item Tag Description Announcements 0 or NA 0 or NA Announcing of report and control values Input 01hex INP_LOSS 81hex INP_RETURN primary input lost or returned The...

Page 16: ...cards the Error LED is not used Input LED This LED indicated the presence of a valid AES EBU digital audio signal on the input Connection LED This LED illuminates after the card has initialised The L...

Page 17: ...8 09 INTERNAL SYNAPSE BUS Rack controller P AES EBU OUT 1 DAD08 only AES EBU IN AES EBU DECODER AES EBU OUT 2 AES EBU OUT 3 AES EBU OUT 4 AES EBU OUT 5 AES EBU OUT 6 AES EBU OUT 7 AES EBU OUT 8 STATUS...

Page 18: ...1 BPL05 and BPL05D BPL01 BPL05 BPX01 BPL05D Fiber BPL01T_FC PC BPL01T_SC BPL01R_FC PC and BPL01R_SC DAD 08 AES EBU I N A E S E B U O U T 8 7 6 5 3 4 2 1 4 7 DAD 08 8 6 5 A E S E B U O U T 1 3 2 A E S...

Page 19: ...17 BPL05D...

Reviews: