Maintenance

Cleaning of cooler by draining the water

To drain the left over water from the tank pull to remove the drain plug given at 
the lower back side of the tank. After draining, push to fix the drain plug properly.

It is advisable to drain water on regular basis for better performance & longer life 
of pads

1. Disconnect the power cord before servicing or maintenance.

2. Do not make loose wiring or inferior material in servicing or maintenance to avoid fire hazard.

3) Please stop the device and contact to the authorized service provider in case of electric shock found on cooler.

4) Please disconnect the power supply before opening any cover to avoid injury due to rotating part / electric shock

5) To clean the tank remove drain plug from bottom side. Drain out all the residual water. Draining out of stagnant water  

from tank is necessary to keep your environment hygienic. 

6) To clean the cooling pad, please unplug the cooler; apply  water on cooling pad from outside. Do it at least once in a 

year , depending on the surrounding environment.

7) Under no circumstances, customer should open the cooler.

8) In case of any difficulties, please contact symphony authorized service provider.

Trouble

Less Cooling

Water Leakage

Fan not Working

Shock on Cooler

Cause

Pump is switched OFF

Humidity control OFF 

(Selected models)

Drain plug is displaced

Grill lock is disengaged

Cooling pad is sagged

Airflow switch is turned OFF

Loose contact at socket

Switch or Motor Malfunction

Device malfunction

Remedy

Switch ON the pump

Ensure that the humidity control knob is ON.

Ensure that the drain plug is positioned properly

Relock the grill

Change the cooling pads

Switch ON the fan by selecting the required speed

Rectify faulty wiring / Socket in the house

Call the nearest service provider

Call the nearest service provider

Trouble Shooting

Note :  The blower/fan motor comes equipped with thermal overload protection.

6

Summary of Contents for DiET 12

Page 1: ...phonylimited com CUSTOMER CARE Owner s Manual Warranty Card World Leader in Air Cooling 1 For selected models only Intertek Conforms to UL Std 507 3159290 US CM For service support contact Symphony Ltd at 602 281 7816 For sales inquiries contact Sylvane at 1 800 934 9194 or at Sylvane com ...

Page 2: ...y lifting the lid on top or through front or through spout at the back You may also add ice cubes for faster cooling Water may be poured up to the highest point or F of the water level indicator You may keep a small container below over flow hole to avoid spillage of water on your floor carpet For longer life of pump always operate it with sufficient water in the tank 2 FLOAT VALVE You may pull to...

Page 3: ...o Jr Storm 70i Storm 100i models Sit back and enjoy Set controls as desired Adjust horizontal louver manually as desired 3 Plug in to power source and switch on Switch on the pump of the cooler by putting the control knob in cool position but keeping the airflow control in OFF position Wait for 5 minutes for the pad to get wet properly ...

Page 4: ...dicated by water symbol displayed on LCD Pump will not start if the water level is low and this will be indicated by a buzzer for 5 seconds and water symbol on LCD will blink 4 FAN Fan will increase the speed by pressing button each time from any speed between 1 to 8 level similarly Fan will decrease the Fan speed 5 SWING Press button to switch on off the swing function 6 AUTO Auto function The sp...

Page 5: ...ated by water icon glowing in WHITE Low water level will be indicated by a buzzer for 5 seconds and water icon will start blinking in red colour 3 FAN When started the fan icon will glow Press the button for High Medium and Low speeds The selected speed will be indicated by glowing LED 4 SWING Press button to switch on off the swing function Swing icon will glow when switched ON 5 TIMER Press the ...

Page 6: ... your environment hygienic 6 To clean the cooling pad please unplug the cooler apply water on cooling pad from outside Do it at least once in a year depending on the surrounding environment 7 Under no circumstances customer should open the cooler 8 In case of any difficulties please contact symphony authorized service provider Trouble Less Cooling Water Leakage Fan not Working Shock on Cooler Caus...

Page 7: ...5 Sumojr 185 175 150 0 85 1 6 Jumbo 70 Jumbo 50 Jumbo 41 Jumbo 21 110 120 110 0 5 1 0 110 105 105 0 5 1 1 Ninja 180 195 160 0 9 1 6 Sumo Siesta 180 195 160 0 9 1 6 Remote Models 205 195 1 0 1 9 Winter i 190 220 V 60Hz Rated 110 V 60Hz 230 V 50Hz 220 V 60Hz 110 V 60Hz Power watts max Rated Current A Rated Voltage Frequency 220V 60Hz 110V 60Hz 230 50Hz single Phase Model Tech Specs Class MADE IN IND...

Page 8: ... DIET12T DIET22T DIET33T DIET50T SUMO MODELS STORM 100 I STORM 70 I CLASS I MODELS KAIZEN KAIZEN JR SUMO JR MODELS DIET 8I DIET 12I DIET 22I DIET 33I DIET 50I HICOOL SMART I DIET 8E DIET 22E DIET 50E DIET 8T CR DIET 22T CR DIET 50T CR HICOOL SMART WINTER I Note WATER LEVEL SENSOR IS APPLICABLE IN SELECT MODELS VARIANTS 8 ...

Page 9: ...e facility for examination and or repair 3 To avoid electric shock connect only to an outlet provided with a ground fault circuit interrupting device ELCB Earth leakage current breaker 4 Cooler is not to be used by children or person with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given proper supervision or instruction 5 Children must...

Page 10: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly If you wish to discard this product please contact your local authorities or dealer from where it was purchased and ask for correct method of disposal Symphony cooler works on inverter The inverter should be of sine wave type of appropriaterating 10 ...

Page 11: ...inate on the expiry of the warranty period of 12 months from the date of purchase even if the product may not be used for any time during the warranty period for any reason whatsoever 6 Cooling pads and outer plastic parts are not covered under warranty 7 The company shall not be liable in any case for any loss or damage caused to any property death or disability caused to any human life arising o...

Page 12: ... Bakeri Circle Navarangpura Ahmedabad Gujarat India 380 014 E mail services symphonylimited com Revision 00 Date 25 04 2013 For service support contact Symphony Ltd at 602 281 7816 For sales inquiries contact Sylvane at 1 800 934 9194 or at Sylvane com ...