1-11-18
BE4200F01022
Power Supply CBA Top View
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
"Ce symbole reprèsente un fusible à fusion rapide."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de m
ê
me type.
Risk of fire
-replace fuse as marked.
"This symbol means fast operating fuse."
A V
F
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F2001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Summary of Contents for CSHP80G
Page 1: ...SERVICE MANUAL DVR HDD with DVD Player CSHP80G...
Page 33: ...1 11 4 AV 2 5 Schematic Diagram E41A1SCAV2...
Page 34: ...1 11 5 AV 3 5 Schematic Diagram E41A1SCAV3...
Page 35: ...1 11 6 AV 4 5 Schematic Diagram E41A1SCAV4...
Page 38: ...1 11 9 SW Schematic Diagram E41A1SCSW ATA Schematic Diagram E41A1SCAT...
Page 40: ...1 11 11 DVD Main 2 3 Schematic Diagram E41A1SCD2...
Page 41: ...1 11 12 DVD Main 3 3 Schematic Diagram E41A1SCD3...
Page 45: ...1 11 16 BE41A0F01011A AV CBA Top View...
Page 57: ...1 17 2 E41A1PEX Packing S3 S2 S1 X10 S10 S2 X20 X4 A7 X3 X1 X2 X5...
Page 65: ...CSHP80G E41A1CD 2006 4 14...