Symmons Identity 6705 Operation & Maintenance Manual Download Page 1

Identity

Model Numbers

Shower/Hand Shower System

Operation & Maintenance Manual

6705

Modifications

Specification

6705

Identity Shower/Hand Shower System

Warranty

Limited Lifetime

 - to the original end purchaser in 

consumer/residential installations.

5 Years

 - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete 
warranty information.

Compliance

Certified by
CSA Group

Shower/hand shower system powered by the Temptrol

®

 

pressure-balancing valve. Features adjustable stop screw 
to limit handle turn, separate two function diverter, wall 
elbow, in-line vacuum breaker, 60" flexible metal hose, 
hand shower cradle, 1 mode hand shower, 1 mode 
showerhead with easy to clean rubber nozzles and 
standard 2.5 gpm (9.5 L/min) flow restrictors. Components 
made from metal and nonmetallic materials, plated in 
standard polished chrome finish.

Note: 

Append appropriate -suffix to model number.

For California Residents

WARNING:

 This product contains chemicals known to the 

State of California to cause cancer, birth defects, or other 
reproductive harm.

-1.5

1.5 gpm (5.7 L/min) flow restrictor

-2.0

2.0 gpm (7.6 L/min) flow restrictor

-72

6' metal hose in place of 5' standard 
metal hose

-143

3 mode showerhead

-145

5 mode showerhead

-231

2 mode showerhead

-B30

30" slide bar in place of wall cradle

-B48

48" slide bar in place of wall cradle

-CHKS

Integral check stops - for use in 
installations where a positive shut-off 
device is used downstream of mixing valve

-IPS 

1/2" female IPS connections

-L/HD

Less showerhead

-L/HS

Less hand shower

-LP

Loop handle

-LR

Lever handle

-OP

13" oval plate

-QD

Quick disconnect on hand shower units

-R

White vinyl hose in place of metal hose

-REB-TRM

Rebuild trim kit

-REV

Reverse coring, hot on right, cold on 
left, for back to back installations

-STN

Satin Nickel finish

-T724

24" slide / grab bar with ADA hand 
shower in place of standard hand 
shower unit

-T736

36" slide / grab bar with ADA hand 
shower in place of standard hand show-
er unit

-TRM

Trim only, valve not included

-X

Integral service stops - allows water 
shutoff at valve for service

CG

-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm (5.7 L/min)

2.0 gpm (7.6 L/min)

Summary of Contents for Identity 6705

Page 1: ...known to the State of California to cause cancer birth defects or other reproductive harm 1 5 1 5 gpm 5 7 L min flow restrictor 2 0 2 0 gpm 7 6 L min flow restrictor 72 6 metal hose in place of 5 sta...

Page 2: ...asurements A 5 7 8 149 mm B 4 5 8 117 mm C Male 1 2 NPT fitting must be recessed 1 4 6 mm from finished wall D Diverter Valve Hole Size Min 3 76 mm Max 3 1 4 83 mm E 3 5 8 92 mm F 2 7 8 73 mm G Ref 10...

Page 3: ...104 I Showerhead 672SH J K Shower Arm Flange 300S L M Handle Set Screw RTS 084 N Dome Cover T 19 O P Diverter Escutcheon Kit 67 DIV Q R S Shower Escutcheon Kit 6700 ESC Tools Required for Installation...

Page 4: ...covers N to valves Turn clockwise to secure Installation 1 1 2 3 K J 6 Attach shower arm J and flange K to vertical shower pipe Turn clockwise to tighten 5 Install handles L to valves Secure handles w...

Page 5: ...radle 9 Place mounting plate C in position mark and drill 3 16 holes for tile anchors T1 5 16 holes for drywall anchors T2 Install anchors 10 Remove cover of hand shower cradle E Install cradle and mo...

Page 6: ...dustries Inc symmons com gethelp symmons com ZV 3198 REV B 021617 Problem Cause Solution Finish is spotting Elements in water supply may cause water staining on finish Clean finished trim area with a...

Page 7: ...5 7 L min 2 0 Reductor de caudal de 2 0 gpm 7 6 L min 72 Manguera de metal de 6 pies en vez de la est ndar de 5 pies 143 Cabezal de ducha de 3 modos 145 Cabezal de ducha de 5 modos 231 Cabezal de duch...

Page 8: ...B 4 5 8 117 mm C La rosca macho NPT de 1 2 debe estar empotrada a 1 4 6 mm de la pared terminada D Tama o de los orificios de la v lvula de desv o M n 3 76 mm M x 3 1 4 83 mm E 3 5 8 92 mm F 2 7 8 73...

Page 9: ...de ducha 672SH J K Brida del brazo de la ducha 300S L M Manija Tornillo de presi n RTS 084 N Cubierta del domo T 19 O P Desviador Equipo de escudete 67 DIV Q R S Juego de escudete para la ducha 6700 E...

Page 10: ...ar Instalaci n 1 1 2 3 K J 6 Una el brazo de la ducha J y la brida K al tubo vertical de la ducha Gire en el sentido de las manecillas del reloj para apretar 5 Instale las manijas L en las v lvulas As...

Page 11: ...grosor o menos inserte la herramienta para anclas T3 en la ancla para yeso T2 para sujetarla detr s de la pared antes de instalar el soporte de pared 1 2 4 E F C 3 5 3 1 2 4 A H H G B 9 Coloque la pla...

Page 12: ...abado Limpie el rea del acabado utilizando un pa o suave jab n neutro y agua o con un limpiador no abrasivo y luego enjuague r pidamente con agua Tabla de resoluci n de problemas Funcionamiento Contro...

Page 13: ...gpm 5 7 L min 2 0 R ducteur de d bit de 2 0 gpm 7 6 L min 72 Boyau de 6 pieds au lieu du boyau en m tal standard de 5 pieds 143 Pomme de douche 3 modes 145 Pomme de douche 5 modes 231 Pomme de douche...

Page 14: ...m B 4 5 8 po 117 mm C Raccord NPT 1 2 po m le doit tre encastr 1 4 po 6 mm du mur fini D Taille du trou pour la vanne de d rivation Min 3 po 76 mm Max 3 1 4 po 83 mm E 3 5 8 po 92 mm F 2 7 8 po 73 mm...

Page 15: ...he 672SH J K Bras et bride de douche 300S L M Assemblage Vis de pression RTS 084 N Couvercle en d me T 19 O P Organe de d rivation Ensemble rosace 67 DIV Q R S Douche Ensemble rosace 6700 ESC Outils r...

Page 16: ...achez le bras de douche J et la bride K au tuyau de douche vertical Tournez dans le sens des aiguilles d une montre pour serrer 5 Installez les poign es L aux vannes Fixez les poign es avec la vis de...

Page 17: ...n s che de 1 2 po d paisseur ou moins ins rer l outil d ancrage T3 dans le dispositif d ancrage T2 de la cloison pour le fixer derri re le mur avant d installer le support mural 9 Placez la plaque de...

Page 18: ...zone avec un chiffon doux en employant de l eau et du d tergent doux ou un nettoyant non abrasif et rincer rapidement l eau Tableau de r solution des probl mes Fonctionnement Contr le de la d rivation...

Reviews: