If the PTP flow is not as expected, here are some considerations:
Although it would likely require special user configuration, make sure the
grandmaster clock does not have its PTP port disabled. A disabled port will not
support PTP flow. TimeProvider 500 provides a similar setting (see the
command), but the port is enabled by default.
Although perhaps unlikely, it is possible that the grandmaster does not have
sufficient resources to support the requested PTP flow. For example, a
grandmaster has a limit on how many clients can be supported.
A quick check for PTP flow can be seen by looking at the 1588 connector's LEDs.
However, for a more reliable and detailed confirmation of PTP flow, use the
query to observe the actual flow rate shown in the “Flow Direction” section of
the status response from the TimeProvider 500 as shown in
, on page 63 for more information about the results of the
query.
Configure Frequency Outputs
By factory default, the TimeProvider 500 produces 2.048 MHz output and 1PPS
output. If this is the desired output, no configuration is needed.
The
show output
command identifies the current output configuration. The
following example shows that the TimeProvider 500 is currently generating 2.048
MHz clock from OUT1, OUT3, and OUT4 and a 1 PPS signal from OUT2.
TP-500> show status
Current Time : 21:51:38 11/09/2009 (UTC)
FLL state : Normal FLL [2840 min] Temperature
Reference : GM2 Avg : 41.01 C
Correction Freq : -10.12 ppb Min : 40.88 C
Phase : 0.00 ppb Max : 41.06 C
Output MDEV Estimate : 0.0002 ppb 5min : 55.37 mC
Residual Phase Error : 2377.13 ns 60min : 166.04 mC
Minimal RTD : 12.57 usec
--------------------------------------------------------------------------
Flow Direction : (GM to client) (client to GM)
GM1 (pkts/s): 0 0
GM2 (pkts/s): 64 64
Weight (%): 1.00 99.00
Transient free (/900): 900 900
Transient free (/3600): 3600 3600
Percentile Clustering(%): 99.8 99.8
Operational Min TDEV(ns): 2.7 1.8
Operational MAFE (ppb): 0.01 0.01
Min Cluster Width (ns): 100.0 100.0
Mode Width (ns): 100.0 200.0
--------------------------------------------------------------------------
Flow State : (GM1)Signaling (GM2)Normal
Clock id : (GM1)00:00:00:00:00:00:00:00 (GM2)00:B0:AE:FF:FE:01:31:65
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...