12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference
59
Chapter 2 TL1 Reference
Retrieve Frequency Parameters
Retrieve Frequency Parameters
This command returns the MTIE threshold settings for the specified port on a DS1,
E1, Sine, or GPS Input module.
Syntax
RTRV-PRMTR-FREQ:[tid]:[aid]:ctag;
Response Format
^^^"aid:freq,fae,fac,fbe,fbc,fatau,fbtau" <cr lf>
where:
aid
= access identifier of the port
fae
= frequency error threshold for A
fac
= clear threshold for A
fbe
= error threshold for B
fbc
=
clear threshold for C
fatau
= frequency error for A
fbtau
= frequency error for B
Related Commands
Parameter
Value
Description
[aid]
ALL
Retrieves the MTIE threshold parameters from all Input
modules in the shelf.
S1Ay-z
Retrieves the MTIE threshold parameters from the
specified input port.