Set MTIE Parameters
Set MTIE Parameters
This command sets the input MTIE alarm thresholds (EL1 or EL2) and the clear
thresholds (CL1 or CL2) for the specified input. This command is valid for DS1, E1,
Sine, and GPS Input modules.
Syntax
SET-PRMTR-MTIE:[tid]:[aid]:ctag::[threshold],[t10],[t100],[t1k],
[t10k],[t100k];
Related Commands
Parameter
Format
Description
aid
S1Ay[-z]
Sets the parameters for the specfied Input module [or
port].
threshold
EL1 | EL2
Sets the input MTIE alarm threshold for the specified
module [or port].
CL1 | CL2
Sets the clear threshold for the specified module [or port].
t10,
t100,
t1k,
t10k,
t100,
Sets the error limits in ns for the measurement time
period.
Range = [0 – 60000]