Chapter 6 Alarms and Events
DS1 Output Module Alarms and Events
290
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
DS1 Output Module Alarms and Events
lists the alarms and events for the DS1 Output module, and includes the
typical response for each alarm or event, it’s event number, and a description or a
suggested corrective action. The SNMP MIB trap is listed in the Alarm/Event/Trap
Description column.
lists the default parameters for the DS1 Output
module alarms.
Table 6-18. DS1 Output Module Alarm and Event Messages
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action
000
Redundant, Fault
Output alignment problem. Disable module, then re-enable.
001
Module Match, Invalid
A redundant pair has one DS1 module and one E1 module.
Replace module.
002
Clk-A, Lost
Module in slot A1 is in warm-up mode or has other problems.
003
Clk-B, Lost
Module in slot A12 is in warm-up mode or has other problems.
004
Clk-C, Lost
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
005
Clk Level, Below
Clock A or B is below output module setting.
006
Clk Selected, None
No clocks, no output.
007
PortFlt, Active, 40000
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
008
VCXO, Lost
VCXO problems, re-seat or replace module.
009
PLL, Unlocked
No clocks or VCXO. Re-seat and check clocks.
010
Configuration, Fault
Redundant configuration mismatch. Re-seat or replace module.
011
Hdw Config, Fault
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services.
012
Clk-D, Lost
Only in SDU. Loss of backup clock. Check cable.
129
Install, DS1 Output Module
Module Installed.
130
Remove, DS1 Output Module
Module Removed.
131
Enable, DS1 Output Module,
COML
Module Enabled.
132
Disable, DS1 Output
Module, COML
Module Disabled.
133
Restart, in 5 seconds, COML
User request for a module to reboot.
144
Cannot Enable, Output
Module, COML
Cannot enable module due to configuration error.
193
Frame Mode, ESF, COML
Output framing type change.