RS-485 Termination

Both the ARC and the Control I/O feature an RS-485 termination jumper. Jumper J17 inside the Control I/O by the RS-485 jack 

enables and disables termination. Jumping pins 1 and 2 = terminated, pins 2 and 3 = open. For maximum signal integrity, follow 

the termination guidelines below:

RS-485 TERMINATION GUIDELINES

Daisy chain length

Termination

0 - 200 ft.

No termination required

200 - 1000 ft. (if powering over CAT-5)

Terminate at Control I/O

> 1000 ft. (or if not powering over CAT-5) Terminate at Control I/O and at the last ARC in each chain

For star configurations, terminate at the Control I/O.

MIDI I/O

With the DB15 MIDI I/O “joystick” port, the Control I/O can function as a MIDI Continuous Controller (CC) to RS-485 Controller 

translator. The DB15 port uses a standard to (2) DIN 5 MIDI IN and MIDI OUT cable adapter. (Adapter not included). The 

adapter is the same that most all computer sound cards with a joystick port use and is available at many computer and music 

supply outlets. (Please see the SymNet Designer online help for information on how to map a MIDI Controller number to an RS-

485 Controller number in a SymNet DSP design.)

Device Address Quick Reference

Every RS-485 device (including all ARCs and Control I/Os) connected to the same SymNet Ring must be uniquely identified. 

You may use the pictorial diagrams below to quickly set up and understand the device address DIP switches on the Control I/O. 

Any time the DIP switches are changed, the unit must be power cycled for the changes to take effect.

Note:

 The Control I/O contains field-upgradable firmware. Upgrading is facilitated by DIP switch #2 labeled “UPGRADE / RUN”. 

Unless instructed by Symetrix Technical Support personnel or a Symetrix Technical Bulletin, this switch should remain in the 

“RUN” position.

RS-485 Termination, MIDI I/O, Device Address Quick Reference

Control I/O DIP Switch Settings

NOTE:

 For the sake of space, only switch settings for the first 8 addresses are pictured.

An address of up to 31 is possible (all DIP switches down). For systems containing

32 total Control I/O's, an address of zero (0) is available (all DIP switches UP).

Address 1

Address 2

Address 4

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

Address 3

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

Address 5

Address 6

Address 8

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

Address 7

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

ASCII / SYMNET

UPGRADE / RU

N

RESER

VED

RS-485

ADDR

1 2 4 8 16

Summary of Contents for SymNet Audio Matrix Control I/O

Page 1: ...g prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electri cian for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufactu...

Page 2: ...d DB15 joystick to 2 DIN 5 MIDI IN and MIDI OUT cables adapter Adapter not included REMOTE ARCs 4 x RJ 45 Distributes power and RS 485 data to one or more ARCs per port See ARC Network Design RELAY OUTPUTS Euroblocks 4 x SPDT relays rated at 3A 24VDC resistive 0 3A 60VDC resistive and can be wired normally open or normally closed OPEN COLLECTOR OUTPUTS Euroblocks 8 x open collector outputs with pa...

Page 3: ...third party products which are compatible with Symetrix products rests solely with the qualified contractor consultant or system designer Open Collector Output Wiring The following illustrations depict three typical open collector output hook ups The most common uses for the open collector outputs are to fire external LED indicators LED lit when OC inactive or drive external relays Please see the ...

Page 4: ...lp a system designer determine power requirements based upon cable length number of ARCs and the power supply to be used This spreadsheet can be downloaded from the SymNet Technical Support pages at http www symetrixaudio com SymNet_Web index htm Relay Outputs Remote ARCs ARC Network Design The following table gives some indication of cabling limitations based on DC power only the table is not rel...

Page 5: ...Net DSP design Device Address Quick Reference Every RS 485 device including all ARCs and Control I Os connected to the same SymNet Ring must be uniquely identified You may use the pictorial diagrams below to quickly set up and understand the device address DIP switches on the Control I O Any time the DIP switches are changed the unit must be power cycled for the changes to take effect Note The Con...

Page 6: ...mands but instead to a simple ASCII based protocol suitable for AMX Crestron type controllers or even a simple terminal program Command Set The address field must match the value of the address on the specific unit s DIP switch If the address field does not match then the command is ignored and no response is sent which allows multiple units to reside on the same RS 485 bus If the address is corre...

Page 7: ... open collectors to be set This is useful for initializing the open collector outputs to a given state on powerup Command SO address output state cr Where output is a decimal number 1 8 and state is 0 for off and 1 or greater for on When the open collector is off the voltage at the open collector is pulled high to 5 volts allowing an attached LED to light When the open collector driver is on there...

Page 8: ...mal number 1 4 and state is 0 for off and 1 or greater for on An off state of the relay corresponds to the NC of the relay connector being connected to the common C connection An on state corresponds to the NO of the relay connector being connected to the common C connection Response ACK NAK cr SE Set Internal Encoder Initial Value Allows the powerup value of the internal encoders to be set This i...

Page 9: ...ontroller number 1 127 that has changed will be returned Each poll will return the lowest numbered changed controller until all the changed parameters have been reported Only MIDI channel 1 is decoded where lower nibble 0 in the MIDI control change command byte A typical poll sequence would be If Ctrl MC addr 0 then Value RM addr Ctrl RM Read MIDI Input Value Allows an external MIDI input to be re...

Page 10: ......

Page 11: ...incidental or consequential damages including but not limited to damage for loss of revenue cost of capital claims of customers for service interruptions or failure to supply and costs and expenses incurred in connection with labor overhead transportation installation or removal of products substitute facilities or supply houses Servicing the Control I O If you have determined that your Control I ...

Reviews: