25
Integrator Series Room Combine 788
Select the firmware upgrade .cab file and click Open.
Click the Start button to begin the process and a status bar
will show progress of the upgrade.
When finished a confirmation window will appear. Click OK
to complete the Firmware Upgrade process.
Architects and Engineers Specifications
The device shall provide eight inputs that are selectable as line or mic
level with phantom power and four line level inputs. All signal processing,
mixing and routing functions (including input gains) shall be controllable
via software. Audio inputs and outputs shall be accessed via rear panel
Phoenix connectors.
The Graphical User Interface (GUI) software shall be installer
programmable using the Windows® XP or Vista operating system.
Computer connection and control shall be via the device’s rear panel
Ethernet connector. The GUI shall provide display and control of all signal
processing and configuration functions including, but not limited to: Input
and Output Gain • Highpass Filtering • Lowpass Filtering • Parametric
Equalization • Compression • Limiting • Automatic Gain Control •
Feedback Elimination • Automatic Mixing • Signal Routing • Delay •
Polarity. The Room Combining layout, relationship, and logic shall be
configured by a Wizard. This Wizard shall also configure all input routing
including paging signal as required.
The front panel shall include input and output signal level indicators as well
as indicators for POWER, NETWORK, and ARC. Additionally, a front panel
LCD shall display certain system parameters and may be programmed as
an ARC for custom user control via the front panel UP, DOWN and MENU
buttons.
External control shall include preset selection as well as I/O level control
and muting, and shall be via industry-standard CAT5 cable with RJ45
connectors using the optional ARC Wall Panel remote controls or the front
panel. All program memory shall be non-volatile and provide program
security should power fail. The device shall provide an on board real time
clock to facilitate automatic, timed changing of presets. A rear panel RS-
232 port is provided for additional 3rd party control options.
Audio conversion shall be 24-bit, 48 kHz. The dynamic range of the
processor shall not be lower than 110 dB A-weighted.
The device shall have an IEC power input socket. The device shall meet
UL/CSA and CE safety requirements and comply with CE and FCC Part
15 emissions limits. The device shall be RoHS compliant. The chassis
shall be constructed of cold rolled steel and moulded plastic, and mount
into a standard 19” 1U EIA rack. The device shall be a Symetrix model
Room Combine 788.
Upgrading Firmware • A&E Specs