If the host does not support RS-485 and RS-485 is the desired communication interface,
an RS-232 to RS-485 conversion box is required. The conversion box must be sourced
locally and configured per manufacture’s instructions. The conversion box is not available
from Symbol Technologies.
To install the MK2000 with a host that does not support RS-485:
1.
Connect the conversion box to the host using an RS-232 cable.
2.
Attach the RS-485 serial cable.
•
Connect the RS-485 serial cable to the LAN port on the MK2000, see
Figure 1-3 on page 1-5 for port locations. Ensure the serial cable is terminated
according to the RS-485 Port Connections described in
Table 2-3.
•
Plug the other end of the RS-485 serial cable into the converter box.
3.
When the data communications installation is completed, return to Installation
Overview on page 2-2 and proceed with step 4 select accessories.
Wired RS-232 Setup
The MK2000 can communicate with a host using a serial cable connected to the Printer/
Scanner (RS-232) port.
1.
Connect the RS-232 serial cable to the Printer/Scanner (RS-232) port on the
MK2000, see Figure 1-3 on page 1-5 for port locations. Ensure the serial cable is
terminated according to the Printer/Scanner (RS-232) Port Connections pin-outs
described in Table 2-4.
2.
Plug the other end of the serial cable into the host.
Summary of Contents for MK2000 MicroKiosk
Page 1: ...Product Reference Guide MK2000 MicroKiosk ...
Page 2: ......
Page 3: ...MK2000 MicroKiosk Product Reference Guide 72 57772 01 Revision A June 2003 ...
Page 52: ...2 22 MK2000 MicroKiosk Product Reference Guide ...
Page 94: ...5 6 MK2000 MicroKiosk Product Reference Guide ...
Page 104: ...6 10 MK2000 MicroKiosk Product Reference Guide ...
Page 108: ...7 4 MK2000 MicroKiosk Product Reference Guide ...
Page 112: ...A 4 MK2000 MicroKiosk Product Reference Guide ...
Page 139: ...C 3 Demo Application Bar Codes Glue Stick Transparent Tape 0 71709 00166 7 0 51131 77138 3 ...
Page 141: ...C 5 Demo Application Bar Codes Standard Staples CD 3 12546 65021 3 0 75678 12772 4 ...
Page 144: ...C 8 MK2000 MicroKiosk Product Reference Guide ...
Page 154: ...D 10 MK2000 MicroKiosk Product Reference Guide ...
Page 170: ...E 16 MK2000 MicroKiosk Product Reference Guide ...
Page 192: ......
Page 193: ......