RS-232C Host Types (LS 6004)
To select an RS-232C host interface, scan one of the bar codes
that begin on the next page. Refer to the table below for the
defaults set for the selected host type. These defaults take
precedence over the standard defaults.
Parameter
Standard
ICL
FUJITSU
NIXDORF
Mode A/
Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission
Format
Data as is Data/Suffix Data/Suffix Data/Suffix
Suffix
CR/LF
(7013)
CR (1013) CR (1013) CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
Even
Even
None
Odd
Hardware
Handshaking
None
RTS/CTS
Option 3
None
RTS/CTS
Option 3
Software Handshaking
None
None
None
None
Serial Response Time-
out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No
data to
send
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the