background image

LS 6000i Series Product Reference Guide

A-12

ALT Keys

Keystroke

ALT Keys

Keystroke

ALT Keys  Keystroke

2064

ALT 2

2075

ALT K

2086

ALT V

2065

ALT A

2076

ALT L

2087

ALT W

2066

ALT B

2077

ALT M

2088

ALT X

2067

ALT C

2078

ALT N

2089

ALT Y

2068

ALT D

2079

ALT O

2090

ALT Z

2069

ALT E

2080

ALT P

2091

ALT [

2070

ALT F

2081

ALT Q

2092

ALT \

2071

ALT G

2082

ALT R

2093

ALT ]

2072

ALT H

2083

ALT S

2094

ALT 6

2073

ALT I

2084

ALT T

2095

ALT -

2074

ALT J

2085

ALT U

Misc. Key

Keystroke

Misc. Key Keystroke Misc. Key Keystroke

3001

PA 1

3009

CMD 7

3017

°

3002

PA 2

3010

CMD 8

3018

1/2

3003

CMD 1

3011

CMD 9

3019

3004

CMD 2

3012

CMD 10

3020

§

3005

CMD 3

3013

¥

3021

|

3006

CMD 4

3014

£

3022

0/00

3007

CMD 5

3015

¤

3008

CMD 6

3016

¬

Table A-4. ASCII Character Set (Continued)

Summary of Contents for LS 6000i

Page 1: ...Product Reference Guide LS 6000i Series...

Page 2: ...LS 6000i Series Product Reference Guide 72 51596 01 Revision A July 2001...

Page 3: ...k from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereund...

Page 4: ...ervice Information xi Symbol Support Center xii Warranty xvi Warranty Coverage and Procedure xvii General xviii Chapter 1 Introduction Overview 1 1 Using Your Scanner 1 3 Chapter 2 Setup Unpacking 2 1...

Page 5: ...Your Scanner 4 1 Scan Zone 4 2 Technical Specifications 4 3 Troubleshooting 4 5 Chapter 5 Programming Operational Parameters 5 1 Defaults 5 2 Set Default Parameter 5 10 Host Type 5 11 IBM 46XX Host Ty...

Page 6: ...nd EAN 5 75 Decode UPC EAN Supplementals 5 76 Decode UPC EAN Supplemental Redundancy 5 78 Transmit UPC A Check Digit 5 79 Transmit UPC E Check Digit 5 80 Random Weight Check Digit 5 81 UPC A Preamble...

Page 7: ...s for Interleaved 2 of 5 5 113 I 2 of 5 Check Digit Verification 5 116 Transmit I 2 of 5 Check Digit 5 118 Convert I 2 of 5 to EAN 13 5 119 Codabar Options 5 120 Enable Disable Codabar 5 120 Set Lengt...

Page 8: ...vii Contents Modifier Characters A 5 ASCII Character Set A 9 Tell Us What You Think...

Page 9: ...viii LS 6000i Series Product Reference Guide...

Page 10: ...e brief descriptions of each chapter in this guide Chapter 1 Introduction provides a product overview and a brief description on using the scanner Chapter 2 Setup provides information on connecting th...

Page 11: ...nventions The following conventions are used in this document The term LS 6000i applies to the LS 6000i LS 6004i LS 6005i and LS 6007i except where specifically noted Bullets indicate action items lis...

Page 12: ...and Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem If the equipment is found to be working properly and the proble...

Page 13: ...in United States Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 1 800 653 5350 Canada Symbol Technologies Canada Inc 2540 Matheson Boulevard East Mississauga Ontario Canada L4...

Page 14: ...ustria Denmark Symbol Technologies AS Gydevang 2 DK 3450 Allerod Denmark 7020 1718 Inside Denmark 45 7020 1718 Outside Denmark Europe Mid East Distributor Operations Contact your local distributor or...

Page 15: ...0 Boca Raton Florida 33434 USA 1 800 347 0178 Inside United States 1 561 483 1275 Outside United States Mexico Symbol Technologies Mexico Ltd Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas d...

Page 16: ...1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11 4405668 Inside South Africa 27 11 4405668 Outside South Africa Spain Symbol Technologies S A Edificioi la Piovera Azul C Peonias No...

Page 17: ...as been repaired or altered unless done or approved by Symbol ii which has not been maintained in accordance with any operating or handling instructions supplied by Symbol iii which has been subjected...

Page 18: ...e F O B Symbol s manufacturing plant Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products Customer will pay for the replacement product in c...

Page 19: ...ties on part of Symbol for damages including without limitation special indirect or consequential damages arising out of or in connection with the use or performance of the product Seller s liability...

Page 20: ...with an optional presentation stand The LS 6000i successfully reads most code symbologies densities and colors produced by a wide range of printing techniques The LS 6000i scanner supports the follow...

Page 21: ...ntire line of IBM 468X 469X terminals It also accommodates the full line of Synapse Smart Cables LS 6005i I090 IBM 468X 469X with EAS The LS 6005i I090 also provides additional signal lines for EAS de...

Page 22: ...cted to the scanner the scanner powers up The green LED on top of the scanner illuminates and 3 power up beeps sound indicating the scanner is operational The LS 6000i s LED and beeper indicate scanni...

Page 23: ...LS 6000i Series Product Reference Guide 1 4...

Page 24: ...he Symbol Support Center at one of the telephone numbers listed on page xii KEEP THE PACKING It is the approved shipping container and should be used if you ever need to return your equipment for serv...

Page 25: ...2 1 Plugging Connector into Scanner 3 Gently tug the cable to ensure the connector is properly secured Switching Cables Different cables are required for different hosts To change the scanner cable 1...

Page 26: ...e U S call 609 848 1800 ext 4900 If you are using an EAS cable refer to the Universal Cable EAS Installation Sheet Symbol p n 70 32824 XX Connecting to a Host Following are detailed instructions for c...

Page 27: ...rminal by scanning the appropriate bar code s Depending on your terminal these are located either in Chapter 5 Programming or the Synapse Interface Guide 7 Power up the host terminal Ensure that the s...

Page 28: ...rogrammable by the bar codes in Trigger Mode on page 5 54 Combination Mode Default The omnidirectional scan pattern is always on and ready to decode When the trigger is pulled the scanner emits a sing...

Page 29: ...To scan in hand held mode pick up the scanner and hold it within the scanning range for the bar code If the scanner is in the constant on mode it decodes the bar code automatically If the scanner is...

Page 30: ...seated The scanner emits a constant on omnidirectional pattern To scan a bar code bring the bar code anywhere within 10 in 25 4 cm of the scanner window for a successful decode Bar codes can either be...

Page 31: ...es Product Reference Guide 3 4 When the LS 6000i is removed from the Presentation Stand the scanner operates in the programmed trigger mode see Scanning In Hand Held Mode on page 3 1 for trigger mode...

Page 32: ...eep when it successfully reads a bar code There are three volume settings for this decode beep To change the setting scan the programming bar codes for Beeper Volume on page 5 57 To adjust the frequen...

Page 33: ...status as follows Table 3 1 Beeper Indications Beeper Indication 3 Beeps Power up or reset has occurred 1 Beep A bar code has been successfully decoded 4 Beeps A transmission error has occurred Bar co...

Page 34: ...ons LED Indication Off No power is applied to the scanner On steady The scanner is on and ready to scan or a flash download cable is attached Momentary flash off A bar code has been successfully decod...

Page 35: ...LS 6000i Series Product Reference Guide 3 8...

Page 36: ...leaning of the scan window to remove fingerprints or other debris Since the LS 6000i scan window is a high performance optical element care should be given during cleaning Use only a mild soap and wat...

Page 37: ...ry long and narrow ones easily from almost any angle The scan pattern is projected directly out of the scan window creating the three dimensional scan zone shown below To read a bar code present the b...

Page 38: ...ine Scan Pattern 60 scans per second Decode Depth of Field Maximum working distance is 10 in 25 4 cm on 100 UPC EAN symbol Decode Capability UPC EAN JAN with and without supplementals Code 128 Code 39...

Page 39: ...and natural outdoor direct sunlight lighting conditions Flourescent incandescent mercury vapor sodium vapor 450 ft candles Sunlight 9000 ft candles Weight 7 4 oz 210 gm Height 7 64 in 194 mm Width 2 7...

Page 40: ...r is properly connected The scanner is not decoding and the green LED is lit Check the bar code to make sure it is not defaced Verify that the code type you are scanning is enabled Verify that the sym...

Page 41: ...is connected to the terminal Make sure the host terminal is properly configured Be sure that you ve scanned the proper host type If you re using RS 232 be sure all RS 232 parameters e g baud rate dat...

Page 42: ...ge these default values by scanning the appropriate bar codes included in this manual These new values replace the standard default values in memory The default parameter values can be recalled by sca...

Page 43: ...4683 after you hear the power up beeps select the proper port from the choices in IBM 46XX Host Types LS 6005i on page 5 11 Defaults The following table lists the defaults for all parameters If you wi...

Page 44: ...Low 5 36 Stop Bit Select 1 5 37 ASCII Format 8 Bit 5 38 Beep on BEL Disable 5 39 Intercharacter Delay 0 5 40 USB LS 6007i 5 41 Set USB Defaults 5 41 USB Device Type IBM Hand Held USB 5 41 Country Sele...

Page 45: ...inuous Omnidirectional 0 5 seconds 5 56 Beeper Volume High 5 57 Beeper Frequency High Frequency 5 59 Time out Between Decodes Same Symbol Triggered 200 msec Constant On 600 msec 5 61 Time out Between...

Page 46: ...71 EAN 8 Enable 5 73 EAN 13 Enable 5 73 Bookland EAN Disable 5 75 Decode UPC EAN Supplementals Ignore 5 76 Decode UPC EAN Supplemental Redundancy 20 5 78 Transmit UPC A Check Digit Enable 5 79 Transm...

Page 47: ...84 Convert UPC E to A Disable 5 86 EAN 8 Zero Extend Disable 5 87 UPC EAN Predecode Block Reject 5 88 UPC EAN Security Levels 0 5 90 Linear UPC EAN Decode Disable 5 93 Linear Supplemental Decode Disa...

Page 48: ...01 Code 39 Code 39 Enable 5 102 Set Length s for Code 39 1 to 55 5 103 Code 39 Check Digit Verification Disable 5 106 Transmit Code 39 Check Digit Disable 5 107 Code 39 Decode Performance Enable Level...

Page 49: ...Verification Disable 5 116 Transmit I 2 of 5 Check Digit Disable 5 118 Convert I 2 of 5 to EAN 13 Disable 5 119 Codabar Codabar Disable 5 120 Set Lengths for Codabar 5 55 5 121 CLSI Editing Disable 5...

Page 50: ...tions Transmit Code ID Character None 5 129 Pause Duration 0 5 132 Prefix Suffix Values 7013 CR LF for serial 5 133 Scan Data Transmission Format Data as is 5 134 Numeric Bar Codes 5 138 Table 5 1 Def...

Page 51: ...LS 6000i Series Product Reference Guide 5 10 Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 5 1 beginning on page 5 2 SET ALL DEFAULTS...

Page 52: ...the following bar code menus IBM 46XX Host Types LS 6005i To select one of the following as a POS Interface scan the appropriate bar code below Note To properly communicate with 468X 9X terminals the...

Page 53: ...LS 6000i Series Product Reference Guide 5 12 Host Type Cont d Port 9B Port 17 9E...

Page 54: ...ts take precedence over standard defaults So if you select Fujitsu RS 232C then select the standard defaults the Fujitsu defaults still take precedence Table 5 2 Terminal Specific RS 232C Parameter St...

Page 55: ...Sec 2 Sec 9 9 Sec Stop Bit Select One One One One ASCII Format 8 Bit 8 Bit 8 Bit 8 Bit Beep On BEL Disabled Disabled Disabled Disabled RTS Line State Low High Low Low No data to send In the Nixdorf M...

Page 56: ...rs are not programmable and are separate from the Transmit Code ID feature The Transmit Code ID feature should not be enabled for these terminals Table 5 3 Terminal Specific Code ID Characters ICL FUJ...

Page 57: ...LS 6000i Series Product Reference Guide 5 16 RS 232C Host Types Cont d To select an RS 232C Host Interface scan one of the following bar codes STANDARD RS 232C ICL RS 232C...

Page 58: ...Programming 5 17 RS 232C Host Types Cont d NIXDORF RS 232C Mode A NIXDORF RS 232C Mode B...

Page 59: ...LS 6000i Series Product Reference Guide 5 18 RS 232C Host Types Cont d FUJITSU RS 232C...

Page 60: ...ate is the number of bits of data transmitted per second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it...

Page 61: ...LS 6000i Series Product Reference Guide 5 20 Baud Rate Cont d BAUD RATE 600 BAUD RATE 1200...

Page 62: ...Programming 5 21 Baud Rate Cont d BAUD RATE 2400 BAUD RATE 4800...

Page 63: ...LS 6000i Series Product Reference Guide 5 22 Baud Rate Cont d BAUD RATE 9600 BAUD RATE 19 200...

Page 64: ...ificant bit of each ASCII coded character Select the parity type according to host device requirements Odd If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure than an od...

Page 65: ...5 24 Parity Cont d Even If you select EVEN parity the parity bit has a value 0 or 1 based on data to ensure than an even number of 1 bits are contained in the coded character EVEN Mark Select MARK par...

Page 66: ...Programming 5 25 Parity Cont d Space Select SPACE parity and the parity bit is always 0 SPACE None Select None if no parity is desired NONE...

Page 67: ...5 26 Check Receive Errors Select whether or not the parity framing and overrun of received characters are checked The type of parity used is selectable through the PARITY parameter CHECK FOR RECEIVED...

Page 68: ...o negate the CTS line If after 2 seconds default the CTS line is still asserted the scanner sounds a transmit error and any scanned data is lost When the CTS line is negated the controller asserts the...

Page 69: ...canner sounds a transmission error and the data is discarded If the above communications sequence fails the scanner issues an error indication In this case the data is lost and must be rescanned If Ha...

Page 70: ...ard RTS CTS Hardware Handshaking STANDARD RTS CTS RTS CTS Option 1 When RTS CTS Option 1 is selected the scanner asserts RTS before transmitting and ignores the state of CTS The scanner deasserts RTS...

Page 71: ...thin 2 seconds default the scanner issues an error indication and discards the data RTS CTS OPTION 2 RTS CTS Option 3 When Option 3 is selected the scanner asserts RTS prior to any data transmission r...

Page 72: ...r instead of that offered by hardware handshaking There are five options If Software Handshaking and Hardware Handshaking are both enabled Hardware Handshaking takes precedence Scan the appropriate ba...

Page 73: ...mits the same data again and waits for either an ACK or NAK After three unsuccessful attempts to send data when NAKs are received the scanner issues an error indication and discards the data The scann...

Page 74: ...from the host before transmitting data If an ENQ is not received within 2 seconds the scanner issues an error indication and discards the data The host must transmit an ENQ character at least every 2...

Page 75: ...the scanner has data to send it then waits for an XON character before transmission The scanner waits up to 2 seconds to receive the XON If the XON is not received within this time the scanner issues...

Page 76: ...nly applies when in one of the ACK NAK Software Handshaking modes or RTS CTS Hardware Handshaking option The delay period can range from 0 0 to 9 9 seconds in 0 1 second increments After scanning the...

Page 77: ...roduct Reference Guide 5 36 RTS Line State This parameter is used to set the idle state of the Serial Host RTS line Scan a bar code below to select LOW RTS line state or HIGH RTS line state HOST LOW R...

Page 78: ...mission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is...

Page 79: ...LS 6000i Series Product Reference Guide 5 38 ASCII Format This parameter allows the scanner to interface with devices requiring a 7 bit or 8 bit ASCII protocol 7 BIT 8 BIT...

Page 80: ...nabled the scanner issues a beep when a BEL character is detected on the RS 232C serial line BEL is issued to gain a user s attention to indicate an illegal entry or other important event BEEP ON BEL...

Page 81: ...st system time to service its receiver and perform other tasks between characters The delay period can range from no delay to 99 msec in 1 msec increments After scanning the bar code below scan two ba...

Page 82: ...device options below depending on the host type and desired mode of operation The mode of operation can be dynamically changed However the scanner resets and re enumerates each time a new mode is sele...

Page 83: ...This mode is supported by a Symbol bar code reader driver and provides maximal flexibility and control over the scanner The software will prompt you to select or install the driver Follow the instruc...

Page 84: ...Programming 5 43 Note When changing USB Device Types the LS 6007i turns off briefly and re enumerates to properly communicate with the host...

Page 85: ...LS 6000i Series Product Reference Guide 5 44 Default USB Type IBM Table Top USB IBM Hand Held USB Default...

Page 86: ...mulation device The MacOS and Windows implement international keyboards differently Select the desired country according to the USB host device If your host platform does not appear here select the Wi...

Page 87: ...ies Product Reference Guide 5 46 Note When changing the Country Selection the LS 6007i turns off briefly and re enumerates to properly communicate with the host North American Standard USB Keyboard Fr...

Page 88: ...Programming 5 47 German Windows German MacOS French Canadian Windows French Canadian MacOS...

Page 89: ...LS 6000i Series Product Reference Guide 5 48 Italian Windows Italian MacOS Spanish ISO MacOS Spanish Traditional Windows...

Page 90: ...Programming 5 49 Swedish MacOS UK English Windows Swedish Windows...

Page 91: ...LS 6000i Series Product Reference Guide 5 50 Japanese Windows Japanese MacOS French MacOS UK English MacOS...

Page 92: ...tion applies only to the HID Keyboard Emulation device Select the desired delay between transmitted keystrokes Only change this setting for slower host PCs that cannot accommodate the speed of data tr...

Page 93: ...sabled and the case of the bar code data is not preserved For example if the CAPS LOCK is off and an uppercase character is transmitted the host reads this as a lowercase character By selecting Enable...

Page 94: ...recognize When Send Bar Codes With Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters i...

Page 95: ...In Triggered Single Scan Line Mode a single scan line appears upon trigger pull If Combination Mode is selected the omnidirectional scan pattern is always on and ready to decode When the trigger is p...

Page 96: ...Programming 5 55 Trigger Mode Cont d TRIGGERED SINGLE SCAN LINE MODE TRIGGERED OMNIDIRECTIONAL MODE...

Page 97: ...9 9 seconds If this value is set to 0 the trigger mode will not return to constant on omnidirectional automatically In this case pull the trigger twice quickly to return to the constant on omnidirect...

Page 98: ...Programming 5 57 Beeper Volume To select a decode beep volume scan the LOW VOLUME MEDIUM VOLUME or HIGH VOLUME bar code LOW VOLUME...

Page 99: ...LS 6000i Series Product Reference Guide 5 58 Beeper Volume Cont d MEDIUM VOLUME HIGH VOLUME...

Page 100: ...Programming 5 59 Beeper Frequency To select a decode beep frequency tone scan the LOW FREQUENCY MEDIUM FREQUENCY or HIGH FREQUENCY bar code LOW FREQUENCY...

Page 101: ...LS 6000i Series Product Reference Guide 5 60 Beeper Frequency Cont d MEDIUM FREQUENCY HIGH FREQUENCY...

Page 102: ...crements from 0 0 to 9 9 seconds Setting this above 0 4 seconds is recommended Scan the bar code below to select a new time out Next scan two numeric bar codes beginning on page 5 138 the first repres...

Page 103: ...ferent symbols It is programmable in 0 1 second increments from 0 0 to 9 9 seconds Scan the bar code below then scan two numeric bar codes beginning on page 5 138 the first representing seconds the se...

Page 104: ...set a Laser On Time scan the bar code below Next scan two numeric bar codes beginning on page 5 138 that correspond to the desired time on Single digit numbers must have a leading zero For example to...

Page 105: ...scanning activity Scan one of the four options Depending on the selection the scanner enters a low power rest mode 15 30 60 or 90 minutes after the last attempted decode The laser blinks during this...

Page 106: ...Programming 5 65 Rest Mode Timeout Cont d 60 MINUTES 90 MINUTES...

Page 107: ...fter Good Decode Scan a bar code below to select whether or not the unit beeps after a good decode If disabled the beeper still operates during parameter menu scanning and indicates error conditions B...

Page 108: ...eaved 2 of 5 Higher security levels are selected for decreasing levels of bar code quality As security levels increase the scanner s aggressiveness decreases Select the security level appropriate for...

Page 109: ...eries Product Reference Guide 5 68 Linear Security Level 2 The following code types must be successfully read twice before being decoded Code Type Length All All LINEAR SECURITY LEVEL 1 LINEAR SECURIT...

Page 110: ...ully read twice before being decoded The following codes must be read three times Linear Security Level 4 The following code types must be successfully read three times before being decoded Code Type...

Page 111: ...LS 6000i Series Product Reference Guide 5 70 LINEAR SECURITY LEVEL 4...

Page 112: ...Programming 5 71 UPC EAN Options Enable Disable UPC E To enable or disable UPC E scan the appropriate bar code ENABLE UPC E DISABLE UPC E...

Page 113: ...LS 6000i Series Product Reference Guide 5 72 Enable Disable UPC A To enable or disable UPC A scan the appropriate bar code ENABLE UPC A DISABLE UPC A...

Page 114: ...Programming 5 73 Enable Disable EAN 8 To enable or disable EAN 8 scan the appropriate bar code below ENABLE EAN 8 DISABLE EAN 8...

Page 115: ...LS 6000i Series Product Reference Guide 5 74 Enable Disable EAN 13 To enable or disable EAN 13 scan the appropriate bar code below ENABLE EAN 13 DISABLE EAN 13...

Page 116: ...Programming 5 75 Enable Disable Bookland EAN To enable or disable EAN Bookland scan the appropriate bar code below ENABLE BOOKLAND EAN DISABLE BOOKLAND EAN...

Page 117: ...not decoded If UPC EAN without supplemental characters is selected and the LS 6000i is presented with a UPC EAN plus supplemental symbol the UPC EAN is decoded and the supplemental characters ignored...

Page 118: ...Programming 5 77 Decode UPC EAN Supplementals Cont d DECODE UPC EAN WITH SUPPLEMENTALS IGNORE UPC EAN WITH SUP PLEMENTALS AUTODISCRIMINATE UPC EAN SUPPLEMENTALS...

Page 119: ...m two to twenty times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected Scan the bar code below to select a...

Page 120: ...rogramming 5 79 Transmit UPC A Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC A check digit TRANSMIT UPC A CHECK DIGIT DO NOT TRANSMIT UPC A CHECK DIGIT...

Page 121: ...Product Reference Guide 5 80 Transmit UPC E Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC E check digit TRANSMIT UPC E CHECK DIGIT DO NOT TRANSMIT UPC...

Page 122: ...be embedded in a UPC A or EAN 13 bar code for additional price verification To enable either of these options or disable the option completely scan the appropriate bar code below DISABLE RANDOM WEIGHT...

Page 123: ...ns are given for lead in characters for UPC A symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The...

Page 124: ...Programming 5 83 UPC A Preamble Cont d SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA...

Page 125: ...ns are given for lead in characters for UPC E symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The...

Page 126: ...Programming 5 85 UPC E Preamble Cont d SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA...

Page 127: ...data to UPC A format before transmission After conversion data follows UPC A format and be affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E TO UPC A allo...

Page 128: ...arameter is enabled five leading zeros are added to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Disabling this parameter returns EAN 8 symbols to their normal format ENAB...

Page 129: ...Reject Predecode Block This option provides additional protection beyond the embedded check digit against mis splicing a UPC EAN block from a symbol that has just been decoded but has not completely...

Page 130: ...Programming 5 89 Accept Predecode Block This option allows immediate decode of a new UPC EAN bar code regardless of the previously decoded UPC EAN bar code s block content ACCEPT PREDECODE BLOCK...

Page 131: ...veness so be sure to choose only that level of security necessary for any given application UPC EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggress...

Page 132: ...UPC EAN Security Level 2 If you are experiencing misdecodes of poorly printed bar codes and the misdecodes are not limited to characters 1 2 7 and 8 select this security level UPC EAN SECURITY LEVEL...

Page 133: ...extreme measure against misdecoding severely out of spec bar codes Selection of this level of security significantly impairs the decoding ability of the scanner If this level of security is necessary...

Page 134: ...nt blocks e g UPC A EAN 8 EAN 13 When enabled a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan This option should be enabled when bar c...

Page 135: ...r five character supplementals When enabled a bar code is transmitted only when both the supplemental block and its adjacent block are successfully decoded within one laser scan This option should be...

Page 136: ...mentals Increasing the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode sec...

Page 137: ...duct Reference Guide 5 96 UPC EAN Decode Performance Cont d If Decode Performance is enabled select a level below UPC EAN DECODE PERFORMANCE LEVEL 1 UPC EAN DECODE PERFORMANCE LEVEL 2 UPC EAN DECODE P...

Page 138: ...s parameter decodes UPC A UPC A with 2 supplemental characters UPC A with 5 supplemental characters and UPC A EAN 128 bar codes Autodiscriminate UPC EAN With Supplemental Characters must be enabled EN...

Page 139: ...LS 6000i Series Product Reference Guide 5 98 Code 128 Options Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below ENABLE CODE 128 DISABLE CODE 128...

Page 140: ...the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enabl...

Page 141: ...ct Reference Guide 5 100 Code 128 Decode Performance Cont d If Decode Performance is enabled select a level below CODE 128 DECODE PERFORMANCE LEVEL 1 CODE 128 DECODE PERFORMANCE LEVEL 2 CODE 128 DECOD...

Page 142: ...Programming 5 101 Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below See Appendix A for details on UCC EAN 128 ENABLE UCC EAN 128 DISABLE UCC EAN 128...

Page 143: ...LS 6000i Series Product Reference Guide 5 102 Code 39 Options Enable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below ENABLE CODE 39 DISABLE CODE 39...

Page 144: ...ny Length are the preferred options One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Code 39 One Discrete Length then scan 1...

Page 145: ...e 5 143 CODE 39 TWO DISCRETE LENGTHS Length Within Range This option allows you to decode a code type within a specified range For example to decode Code 39 symbols containing between 4 and 12 charact...

Page 146: ...Programming 5 105 Any Length Scanning this option allows you to decode Code 39 symbols containing any number of characters CODE 39 ANY LENGTH...

Page 147: ...When enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those code 39 symbols which include a modulo 43 check digit are decoded when t...

Page 148: ...rogramming 5 107 Transmit Code 39 Check Digit Scan a bar code below to transmit the data with or without the check digit TRANSMIT CODE 39 CHECK DIGIT ENABLE DO NOT TRANSMIT CODE 39 CHECK DIGIT DISABLE...

Page 149: ...level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enable this option yo...

Page 150: ...amming 5 109 Code 39 Decode Performance Cont d If Decode Performance is enabled select a level below CODE 39 DECODE PERFORMANCE LEVEL 1 CODE 39 DECODE PERFORMANCE LEVEL 2 CODE 39 DECODE PERFORMANCE LE...

Page 151: ...such as BACKSPACE and RETURN The other 96 are called printable codes because all but SPACE and DELETE produce visible characters Code 39 Full ASCII interprets the bar code special character preceding...

Page 152: ...Programming 5 111 Enable Disable Code 39 Full ASCII Cont d ENABLE CODE 39 FULL ASCII DISABLE CODE 39 FULL ASCII...

Page 153: ...oduct Reference Guide 5 112 Interleaved 2 of 5 Options Enable Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below ENABLE INTERLEAVED 2 OF 5 DISABLE I...

Page 154: ...Discrete Length This option allows you to decode only those codes containing a selected length For example if you select I 2 of 5 One Discrete Length then scan 1 4 the only I 2 of 5 symbols decoded a...

Page 155: ...ange This option allows you to decode a code type within a specified range For example to decode I 2 of 5 symbols containing between 4 and 12 characters first scan I 2 of 5 Length Within Range Then sc...

Page 156: ...5 115 Any Length Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters Note Selecting the Any Length option may lead to misdecodes for I 2 of 5 codes I 2 of 5...

Page 157: ...116 I 2 of 5 Check Digit Verification When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm either Uniform Symbology Specification USS or...

Page 158: ...Programming 5 117 I 2 of 5 Check Digit Verification Cont d USS CHECK DIGIT OPCC CHECK DIGIT...

Page 159: ...Product Reference Guide 5 118 Transmit I 2 of 5 Check Digit Scan a bar code below to transmit the data with or without the check digit TRANSMIT I 2 of 5 CHECK DIGIT ENABLE DO NOT TRANSMIT I 2 of 5 CHE...

Page 160: ...5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN...

Page 161: ...LS 6000i Series Product Reference Guide 5 120 Codabar Options Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below ENABLE CODABAR DISABLE CODABAR...

Page 162: ...ons One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Codabar One Discrete Length then scan 1 4 the only Codabar symbols deco...

Page 163: ...n Range This option allows you to decode a code type within a specified range For example to decode Codabar symbols containing between 4 and 12 characters first scan Codabar Length Within Range Then s...

Page 164: ...Programming 5 123 Any Length Scanning this option allows you to decode Codabar symbols containing any number of characters CODABAR ANY LENGTH...

Page 165: ...en enabled this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note Symbol length does not include start...

Page 166: ...Programming 5 125 NOTIS Editing When enabled this parameter strips the start and stop characters from decoded Codabar symbol ENABLE NOTIS EDITING DISABLE NOTIS EDITING...

Page 167: ...LS 6000i Series Product Reference Guide 5 126 RSS Codes RSS 14 Enable RSS 14 Disable RSS 14...

Page 168: ...Programming 5 127 RSS Limited Enable RSS Limited Disable RSS Limited...

Page 169: ...LS 6000i Series Product Reference Guide 5 128 RSS Expanded Enable RSS Expanded Disable RSS Expanded...

Page 170: ...decoding more than one code type In addition to any single character prefix already selected the code ID character is inserted between the prefix and the decoded symbol The user may select no code ID...

Page 171: ...pe Symbol Identifier UPC A UPC E UPC E1 EAN 13 EAN 8 A Code 39 Code 32 B Codabar C Code 128 ISBT 128 D Code 93 E Interleaved 2 of 5 F Discrete 2 of 5 D 2 of 5 IATA G MSI Plessey J UCC EAN 128 K Bookla...

Page 172: ...Programming 5 131 Transmit Code ID Character Cont d AIM CODE ID CHARACTER NONE...

Page 173: ...set by scanning a two digit number i e two bar codes and are measured in 1 10 second intervals For example scanning bar codes 0 and 1 inserts a 1 10 second pause 0 and 5 gives you a 1 2 second delay...

Page 174: ...s are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 4 in Appendix A for conversion information Numeric bar codes begin on page...

Page 175: ...at To change the Scan Data Transmission Format scan the SCAN OPTIONS bar code below Then select one of four options When you have made your selection scan the ENTER bar code on page 5 137 If you make...

Page 176: ...Programming 5 135 Scan Data Transmission Format Cont d DATA AS IS DATA SUFFIX...

Page 177: ...LS 6000i Series Product Reference Guide 5 136 Scan Data Transmission Format Cont d PREFIX DATA PREFIX DATA SUFFIX...

Page 178: ...Programming 5 137 Scan Data Transmission Format Cont d ENTER DATA FORMAT CANCEL...

Page 179: ...LS 6000i Series Product Reference Guide 5 138 Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1...

Page 180: ...Programming 5 139 Numeric Bar Codes Cont d 2 3...

Page 181: ...LS 6000i Series Product Reference Guide 5 140 Numeric Bar Codes Cont d 4 5...

Page 182: ...Programming 5 141 Numeric Bar Codes Cont d 6 7...

Page 183: ...LS 6000i Series Product Reference Guide 5 142 Numeric Bar Codes Cont d 8 9...

Page 184: ...Programming 5 143 Cancel If you make an error or wish to change your selection scan the bar code below CANCEL...

Page 185: ...LS 6000i Series Product Reference Guide 5 144...

Page 186: ...NC 1 characters are used to delineate fields When EAN 128 symbols are read they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with...

Page 187: ...le or disable one or both code types via bar code menus Table A 1 indicates the behavior of the LS 6000i in each of the four possible parameter settings Table A 1 Reading Standard Code128 UCC EAN 128...

Page 188: ...be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE Enable Enable Read both types of symbols Examples FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1ABCDFNC1E are...

Page 189: ...93 c Code Character see Table A 2 m Modifier Character see Table A 3 Table A 2 AIM Code Identifiers Code Character Code Type A Code 39 C Code 128 ISBT 128 EAN128 E UPC EAN e RSS Family EAN UCC Composi...

Page 190: ...cessing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character co...

Page 191: ...FNC1 Aim Id is transmitted as C1AimId I 2 of 5 0 No check digit processing 1 Reader has validated check digit 3 Reader has validated and stripped check digit Example An I 2 of 5 bar code without check...

Page 192: ...78905 Bookland EAN 0 No options specified at this time Always transmit 0 Example A Bookland EAN bar code 123456789X is transmitted as X0123456789X RSS Family Note In UCC EAN 128 emulation mode RSS is...

Page 193: ...is transmitted in the following format E0 UPC chars terminator E2 supplemental terminator In the LS 6000i however the format is changed to E0 UPC chars E2 supplemental Therefore a UPC with two supplem...

Page 194: ...L B 1026 Z CTRL Z 1003 C CTRL C 1027 A CTRL 1004 D CTRL D 1028 B CTRL 1005 E CTRL E 1029 C CTRL 1006 F CTRL F 1030 D CTRL 6 1007 G CTRL G 1031 E CTRL 1008 H CTRL H 1032 Space Space 1009 I CTRL I 1033...

Page 195: ...1 3 3 1076 L L 1052 4 4 1077 M M 1053 5 5 1078 N N 1054 6 6 1079 O O 1055 7 7 1080 P P 1056 8 8 1081 Q Q 1057 9 9 1082 R R 1058 Z 1083 S S 1059 F 1084 T T 1060 G 1085 U U 1061 H 1086 V V 1062 I 1087 W...

Page 196: ...ar Keystroke 1098 B b 1113 Q q 1099 C c 1114 R r 1100 D d 1115 S s 1101 E e 1116 T t 1102 F f 1117 U u 1103 G g 1118 V v 1104 H h 1119 W w 1105 I i 1120 X x 1106 J j 1121 Y y 1107 K k 1122 Z z 1108 L...

Page 197: ...2069 ALT E 2080 ALT P 2091 ALT 2070 ALT F 2081 ALT Q 2092 ALT 2071 ALT G 2082 ALT R 2093 ALT 2072 ALT H 2083 ALT S 2094 ALT 6 2073 ALT I 2084 ALT T 2095 ALT 2074 ALT J 2085 ALT U Misc Key Keystroke M...

Page 198: ...4008 PF 8 4016 PF 16 4024 PF 24 F Keys Keystroke F Keys Keystroke F Keys Keystroke 5001 F 1 5014 F 14 5027 F 27 5002 F 2 5015 F 15 5028 F 28 5003 F 3 5016 F 16 5029 F 29 5004 F 4 5017 F 17 5030 F 30 5...

Page 199: ...Lock 6046 6063 5 6060 00 6047 6064 6 6048 0 6065 7 Extended Keypad Keystroke Extended Keypad Keystroke Extended Keypad Keystroke 7001 Break 7008 Backspace 7015 Up Arrow 7002 Delete 7009 Tab 7016 Dn Ar...

Page 200: ...2 3 modular connector 2 2 scanner cable 2 1 switching 2 2 cancel bar code 5 143 cleaning 4 1 CLSI editing 5 124 code ID characters AIM A 4 Symbol 5 129 connecting to host 2 3 D default table 5 2 defa...

Page 201: ...amming parameters 5 1 ASCII format 5 38 baud rate 5 19 beep after good decode 5 66 beep on bel 5 39 beeper frequency 5 59 beeper volume 5 57 bookland EAN 5 75 cancel 5 143 check receive errors 5 26 CL...

Page 202: ...l 5 61 transmit code 39 check digit 5 107 transmit code ID character 5 129 transmit I 2 of 5 check digit 5 118 trigger modes 5 54 UCC EAN 128 5 101 UPC A 5 72 UPC A check digit 5 79 UPC A preamble 5 8...

Page 203: ...gered single scan line 3 2 service information xi setup 2 1 connecting interface cable 2 3 connecting power supply 2 3 connecting to host 2 3 installing scanner cable 2 1 programming the scanner 2 4 s...

Page 204: ...How familiar were you with this product before using this manual Did this manual meet your needs If not please explain ________________________________________________________ What topics need to be a...

Page 205: ...72 51596 01 Revision A July 2001 Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300...

Reviews: