Software Handshaking
This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware
handshaking. There are five options.
If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes
precedence.
•
None
: When this option is selected, data is transmitted immediately. No response is expected from host.
•
ACK/NAK
: When this option is selected, after transmitting data, the digital scanner expects either an ACK or
NAK response from the host. When a NAK is received, the digital scanner transmits the same data again and
waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the
digital scanner issues an error indication and discards the data.
The digital scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK.
If the digital scanner does not get a response in this time, it issues an error indication and discards the data.
There are no retries when a time-out occurs.
•
ENQ
: hen this option is selected, the digital scanner waits for an ENQ character from the host before
transmitting data. If an ENQ is not received within the Host Serial Response Time-out, the digital scanner
issues an error indication and discards the data. The host must transmit an ENQ character at least every
Host Serial Response Time-out to prevent transmission errors.
•
ACK/NAK with ENQ
: This combines the two previous options. For re-transmissions of data, due to a NAK
from the host, an additional ENQ is not required.
•
XON/XOFF
: An XOFF character turns the digital scanner transmission off until the digital scanner receives
an XON character. There are two situations for XON/XOFF:
•
XOFF is received before the digital scanner has data to send. When the digital scanner has data to send,
it waits up to Host Serial Response Time-out for an XON character before transmission. If the XON is not
received within this time, the digital scanner issues an error indication and discards the data.
•
XOFF is received during a transmission. Data transmission then stops after sending the current byte.
When the digital scanner receives an XON character, it sends the rest of the data message. The digital
scanner waits up to 30 seconds for the XON.
Summary of Contents for DS 3408
Page 1: ...Symbol DS3408 Product Reference Guide...
Page 2: ......
Page 3: ...Symbol DS3408 Product Reference Guide 72E 68456 04 Revision A June 2007...
Page 6: ...iv DS3408 Product Reference Guide...
Page 18: ...xvi Symbol DS3408 Product Reference Guide...
Page 44: ...3 8 Symbol DS3408 Product Reference Guide...
Page 51: ...User Preferences 4 7 Time Delay to Low Power Mode continued 15 Minutes 2Bh 1 Hour 31h...
Page 56: ...4 12 Symbol DS3408 Product Reference Guide...
Page 62: ...5 6 Symbol DS3408 Product Reference Guide...
Page 86: ...6 24 Symbol DS3408 Product Reference Guide...
Page 132: ...8 22 Symbol DS3408 Product Reference Guide...
Page 138: ...9 6 Symbol DS3408 Product Reference Guide...
Page 160: ...11 14 Symbol DS3408 Product Reference Guide...
Page 162: ...12 2 Symbol DS3408 Product Reference Guide...
Page 240: ...13 78 Symbol DS3408 Product Reference Guide...
Page 272: ...15 24 Symbol DS3408 Product Reference Guide Numeric Keypad continued 7 8 9 Cancel...
Page 337: ...Advanced Data Formatting 15 89 Alphanumeric Keyboard Space Dash...
Page 338: ...15 90 Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued...
Page 339: ...Advanced Data Formatting 15 91 Alphanumeric Keyboard continued...
Page 340: ...15 92 Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued _ Underscore...
Page 342: ...15 94 Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued 6 7 8 9 A B C...
Page 343: ...Advanced Data Formatting 15 95 Alphanumeric Keyboard continued D E F G H I J...
Page 344: ...15 96 Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued K L M N O P Q...
Page 345: ...Advanced Data Formatting 15 97 Alphanumeric Keyboard continued R S T U V W X...
Page 347: ...Advanced Data Formatting 15 99 Alphanumeric Keyboard continued d e f g h i j...
Page 348: ...15 100Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued k l m n o p q...
Page 349: ...Advanced Data Formatting15 101 Alphanumeric Keyboard continued r s t u v w x...
Page 350: ...15 102Symbol DS3408 Product Reference Guide Alphanumeric Keyboard continued y z...
Page 366: ...B 8 Symbol DS3408 Product Reference Guide...
Page 367: ...Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 123ABC 0 12345 67890 5...
Page 369: ...Sample Bar Codes C 3 PDF417 DataMatrix Maxicode...
Page 370: ...C 4 Symbol DS3408 Product Reference Guide QR Code US Postnet UK Postal...
Page 374: ...D 4 Symbol DS3408 Product Reference Guide...
Page 404: ......
Page 405: ......