Installing the Rackmount Command Module
Connect the Interface Cables
Revision A, March 1998
Installation Instructions
25
Caution
The air vents above the power supplies and fans must be free of
obstructions. This includes interface cabling that exits the back of
the command module. Once you connect the cables to the command
module, secure them to the inside of the Data Center cabinet
framework with tie wraps. Be careful not to route the cables across
any sharp edges. On deskside units, loosely bundle the cables with
tie wraps so the cables can exit the cabinet below the back panel.
9
If applicable, attach secondary interface cables (
There is one RS-232 and one Ethernet cable connection for each
controller on the back of the command module.
10
Organize and secure interface cables.
Arrange the interface cables so they clear the vents on the back of the
command module. Secure the cables with tie-wraps.
11
Go to
“Connect the Power Cords” on page 41
End of Procedure