1-4-4
DVDN_SN
Instructions for Handling Semi-
conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 M
Ω
) that is
properly grounded to remove any static electricity that
may be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1 M
Ω
) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on
clothing will not escape through the body grounding
band, be careful to avoid contacting semi-conductors
with your clothing.
<Incorrect>
CBA
Grounding Band
Conductive Sheet or
Copper Plate
1M
Ω
1M
Ω
<Correct>
CBA
Summary of Contents for DP170SL8
Page 1: ...SERVICE MANUAL DVD PLAYER DP170SL8 POWER SKIP SKIP PLAY STOP OPEN CLOSE...
Page 25: ...1 9 4 DVD Main 2 4 Schematic Diagram E6E22SCD2...
Page 26: ...1 9 5 DVD Main 3 4 Schematic Diagram E6E22SCD3...
Page 27: ...1 9 6 DVD Main 4 4 Schematic Diagram E6E22SCD4...
Page 29: ...1 9 8 AV 2 3 Schematic Diagram E6E22SCAV2...
Page 33: ...1 9 12 Function CBA Top View Function CBA Bottom View BE6E20F01012 B...
Page 40: ...1 15 2 E6E22PEX Packing A22 S1 S2 S4 Unit S2 X10 X5 X2 X4 X1...