1-6-6
T7500EA
9. Focus Adjustment
Purpose:
Set the optimum Focus.
Symptom of Misadjustment:
If Focus Adjustment is
incorrect, blurred images are shown on the display.
Note:
Focus VR (FBT) --- MAIN CBA
FBT= Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a Degaussing Coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain clear
picture.
10. Head Switching Position Adjustment
Purpose:
Determine the Head Switching Point during
Playback.
Symptom of Misadjustment:
May cause Head
Switching Noise or Vertical Jitter in the picture.
Note:
Unit reads Head Switching Position automati-
cally and displays it on the screen (Upper Left Corner).
1. Insert the test tape (FL8A, FL8N).
2. Set the unit to the stop condition.
3. Enter the Service mode. (See page 1-4-1.)
4. Press "PAUSE" button on the remote control unit.
5. Confirm that indication of OSD is 6.5H.
11. CCS Text Box Location
When replacing the CRT, the CCS Box might not stay
in appropriate position. Then, replace micro computer.
Note:
This adjustment automatically done by the
microcomputer.
The following 2 adjustments normally are not
attempted in the field. They should be done
only when replacing the CRT then adjust as a
preparation.
12.Purity Adjustment
Purpose:
To obtain pure color.
Symptom of Misadjustment:
If Color Purity Adjust-
ment is incorrect, large areas of color may not be prop-
erly displayed.
* This becomes RED COLOR if push 7KEY with a
service mode.
1. Set the unit facing east.
2. Operate the unit for over 30 minutes before adjust-
ing.
3. Fully degauss the unit using an external degauss-
ing coil.
4. Set the unit to the AUX mode which is located
before CH2 then input a red raster from video in.
5. Loosen the screw on the Deflection Yoke Clamper
and pull the Deflection Yoke back away from the
screen. (See Fig. 6.)
6. Loosen the Ring Lock and adjust the Purity Mag-
nets so that a red field is obtained at the center of
the screen. Tighten Ring Lock. (See Fig. 5,6.)
7. Slowly push the Deflection Yoke toward the bell of
the CRT and set it where a uniform red field is
obtained.
8. Tighten the clamp screw on the Deflection Yoke.
Test point
Adj. Point
Mode
Input
---
Focus Control
---
Monoscope
Tape
M. EQ.
Spec.
---
Pattern Generator
See below.
Test point
Adj. Point
Mode
Input
---
Deflection Yoke
Purity Magnet
---
*Red Color
Tape
M. EQ.
Spec.
---
Pattern Generator
See below.
Figure
BLUE
GREEN
RED
Fig. 5