3. TV AGC Adjustment
Purpose: Set AGC (Auto Gain Control) Level.
Symptom of Misadjustment: AGC does not synchro-
nize correctly when RF input level is too weak and
picture distortion may occur if it is too strong.
Test Point Adjustment Point
Mode
Input
AGC
CH.
▲
/
▼
buttons
---
Color Bar
67.25MHz
60dB
µ
V
Tape
M. EQ.
Spec.
---
Pattern Generator
DC Volt Meter
+2.8V
±
0.3VDC
Notes: AGC --- Main CBA
1. Enter the Service mode. (See page 1-4-1) Then
press number 2 button on the remote control unit.
2. Receive the Color Bar signal for channel 4
(67.25MHz). (RF Input Level: 60dB
µ
V)
3-1. Press CH.
▲
/
▼
buttons so that the voltage of AGC
b2.8V
±
0.3V DC.
(Tuner Type No. TEDH9-300A)
3-2. Press CH.
▲
/
▼
buttons so that the voltage of AGC
b2.8V
±
0.3V DC.
(Tuner Type No. B8055AR)
3-3. Press CH.
▲
/
▼
buttons so that the voltage of AGC
b2.8V
±
0.3V DC.
(Tuner Type No. B8095AP)
4. Turn the power off and on again.
4-1. H Adjustment
Purpose: To get correct horizontal position and size of
screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Test Point
Adjustment Point
Mode
Input
D302
CATHODE
CH
▲
/
▼
buttons VIDEO
----
Tape
M. EQ.
Spec.
----
Frequency
Counter
15.734kHz
±
300Hz
Note: D302 CATHODE --- Main CBA
1. Connect Frequency Counter to INT. MONITOR.
2. Set the unit to the VIDEO mode and no input is
necessary. Enter the Service mode.
(See page 1-4-1)
3. Operate the unit for at least 20 minutes.
4. Press "2" button on the remote control unit and
select H-Adj Mode. (Press "2" button, then display
will change H-Adj and AGC.)
5. Press CH
▲
/
▼
buttons on the remote control unit
so that the display will change "0" to "7."
At this moment, choose display "0" to "7" when the
Frequency counter display is closest to
15.734kHz
±
300Hz.
6. Turn the power off and on again.
4-2. C-Trap Adjustment
Purpose: To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment: If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Test Point
Adjustment Point
Mode
Input
J070
(B-Out)
CH
▲
/
▼
buttons
---
Color Bar
Tape
M. EQ.
Spec.
----
Oscilloscope
200mV P-P
Note: J070 (B-Out)--- Main CBA
1. Connect Oscilloscope to J070.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-4-1)
3. Press "0" button on the remote control unit and
select C-TRAP Mode.
4. Press CH
▲
/
▼
buttons on the remote control unit
so that the carrier leakage B-Out (3.58MHz) value
becomes minimum on the oscilloscope.
5. Turn the power off and on again.
minimum
Fig. 2
1-7-2
T7200EA
Summary of Contents for 6319CCB
Page 18: ...Fig 2 Fig 1 S 1 S 2 S 1 1 REAR CABINET S 1 S 1 S 1 S 1 S 2 1 6 2 T7200DC...
Page 20: ...CRT CBA 6 CRT ANODE CAP S 6 S 6 S 6 S 6 Fig 4 1 6 4 T7200DC...
Page 42: ...Main1 REC Signal REC Audio Signal...
Page 43: ...Main1 PBSignal PB Audio Signal...
Page 46: ...Main2 REC REC Audio Signal REC Video Signal...
Page 47: ...Main2 PB PB Audio Signal PB Video Signal...
Page 50: ...Main3 REC Signal REC Audio Signal REC Video Signal...
Page 51: ...Main3 PBSignal PB Audio Signal PB Video Signal...
Page 54: ...Main4 REC Main4 REC REC Video Signal...
Page 55: ...Main4 PB Main4 PB PB Video Signal...
Page 59: ...Q571 COLLECTOR WF12 PIN 5 OF CN571 WF13 H V CBA Bottom View 1 9 24 1 9 23 BT5200F01022 A...
Page 108: ...6319CCB T7204CE Printed in Japan 2001 03 14 HO...